Ji Hi Kim

Ms. Ji Hi Kim

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in Indoor Air
Verified
Journal Article
Open access
JKJehyun Kim
Jehyun Kim
SJSeongmin Jo
Seongmin Jo
GKGihoon Kim
Gihoon Kim
JKJi Hi Kim
Ji Hi Kim
MSMinki Sung
Minki Sung
Indoor air quality (IAQ) plays a crucial role in safeguarding the health of both patients and healthcare workers in hospital environments. Accurate IAQ analysis and prediction are vital for optimizing ventilation, filtration, and other control measures to maintain a safe indoor atmosphere. This study investigates IAQ in hospital spaces by utilizing long‐term data from internet of things (IoT) sensors installed in general wards and negative pressure isolation wards. Given the significant influence of outdoor air, IAQ requires continuous monitoring across different seasons and extended periods. In this study, IAQ was measured over nearly a year, capturing seasonal variations and long‐term trends. Clustering algorithms were applied to identify complex patterns and detect anomalies in key IAQ parameters, including temperature, CO 2 concentration, and particulate matter 2.5 μ m (PM 2.5 ). These clustering results were then integrated into a long short‐term memory (LSTM) model to enhance IAQ prediction for subsequent time steps. The findings indicate that incorporating clustering results as input variables substantially improves IAQ prediction accuracy. Notably, the root mean squared error for PM 2.5 prediction decreased from 8.51 to 3.99 when clustering results were included. This study underscores the potential of leveraging IoT sensors and machine learning techniques for real‐time IAQ monitoring and forecasting in hospital settings. These insights can support the development of effective control strategies to maintain a healthy and comfortable indoor environment for both patients and healthcare workers.

JBJONG IL BANG
JONG IL BANG
JKJi Hi Kim
Ji Hi Kim
ACAnseop Choi
Anseop Choi
MSMinki Sung
Minki Sung
With the increased incidence of infectious disease outbreaks in recent years such as the COVID-19 pandemic, related research is being conducted on the need to prevent their spread; it is also necessary to develop more general physical–chemical control methods to manage them. Consequently, research has been carried out on light-emitting diodes (LEDs) as an effective means of light sterilization. In this study, the sterilization effects on four types of representative bacteria and mold that occur indoors, Bacillus subtilis, Escherichia coli, Penicillium chrysogenum, and Cladosporium cladosporidides, were confirmed using LED modules (with wavelengths of 275, 370, 385, and 405 nm). Additionally, power consumption was compared by calculating the time required for 99.9% sterilization of each microorganism. The results showed that the sterilization effect was high, in the order 275, 370, 385, and 405 nm. The sterilization effects at 385 and 405 nm were observed to be similar. Furthermore, when comparing the power consumption required for 99.9% sterilization of each microorganism, the 275 nm LED module required significantly less power than those of other wavelengths. However, at 405 nm, the power consumption required for 99.9% sterilization was less than that at 370 nm; that is, it was more efficient and similar to or less than that at 385 nm. Additionally, because 405 nm can be applied as general lighting, it was considered to have wider applicability and utility compared with UV wavelengths. Consequently, it should be possible to respond to infectious diseases in the environment using LEDs with visible light wavelengths.