JONG IL BANG

Dr. JONG IL BANG

Sejong University, Seoul, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in Building and Environment
Verified
Journal Article
Closed access
JPJoon-Young Park
Joon-Young Park
DYDong-Seob Yoon
Dong-Seob Yoon
SLShiying Li
Shiying Li
JPJunseok Park
Junseok Park
JBJONG IL BANG
JONG IL BANG
JAE-WEON JEONGJAE-WEON JEONG
JAE-WEON JEONG

4 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JKJehyun Kim
Jehyun Kim
JBJONG IL BANG
JONG IL BANG
ACAnseop Choi
Anseop Choi
JMJunghyon Mun
Junghyon Mun
MSMinki Sung
Minki Sung
Infectious diseases such as the COVID-19 pandemic have necessitated preventive measures against the spread of indoor infections. There has been increasing interest in indoor air quality (IAQ) management. Air quality can be managed simply by alleviating the source of infection or pollution, but the person within a space can be the source of infection or pollution, thus necessitating an estimation of the exact number of people occupying the space. Generally, management plans for mitigating the spread of infections and maintaining the IAQ, such as ventilation, are based on the number of people occupying the space. In this study, carbon dioxide (CO2)-based machine learning was used to estimate the number of people occupying a space. For machine learning, the CO2 concentration, ventilation system operation status, and indoor–outdoor and indoor–corridor differential pressure data were used. In the random forest (RF) and artificial neural network (ANN) models, where the CO2 concentration and ventilation system operation modes were input, the accuracy was highest at 0.9102 and 0.9180, respectively. When the CO2 concentration and differential pressure data were included, the accuracy was lowest at 0.8916 and 0.8936, respectively. Future differential pressure data will be associated with the change in the CO2 concentration to increase the accuracy of occupancy estimation.

6 September 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
JBJONG IL BANG
JONG IL BANG
JPJeongyeon Park
Jeongyeon Park
ACAnseop Choi
Anseop Choi
JAE-WEON JEONGJAE-WEON JEONG
JAE-WEON JEONG
JKJin Yong Kim
Jin Yong Kim
MSMinki Sung
Minki Sung
A negative pressure isolation ward prevents the outflow of airborne microorganisms from inside the ward, minimizing the spread of airborne contamination causing respiratory infection. In response to recent outbreaks of severe acute respiratory syndrome (SARS) and Middle East respiratory syndrome (MERS), Korea has increased the number of these facilities. However, airborne contaminants that flow into the ward from adjacent areas may cause secondary harm to patients. In this study, the sterilization effect of upper-room ultraviolet germicidal irradiation (UR-UVGI) on microorganisms generated within the negative pressure isolation ward and those flowing inward from adjacent areas was evaluated through field experiments and computational fluid dynamics (CFD) analysis, to assess the potential of this approach as a supplementary measure to control such microorganisms. The sterilization effect was found to be not high because of high-level ventilation. CFD analysis under various conditions shows that the sterilization effect for indoor-generated microorganisms varies with the level of UV radiation, the source locations of the indoor-generated microorganisms, air supplies and exhausts, the UVGI system, and the airflow formed under the specified conditions. Our results show that when the UVGI system is installed in the upper part of the ward entrance, contaminated air from adjacent area is strongly sterilized.

20 November 2025 in Building and Environment
Verified
Journal Article
Closed access
JKJehyun Kim
Jehyun Kim
GKGihoon Kim
Gihoon Kim
JBJONG IL BANG
JONG IL BANG
ACAnseop Choi
Anseop Choi
MSMinki Sung
Minki Sung

JBJONG IL BANG
JONG IL BANG
JKJi Hi Kim
Ji Hi Kim
ACAnseop Choi
Anseop Choi
MSMinki Sung
Minki Sung
With the increased incidence of infectious disease outbreaks in recent years such as the COVID-19 pandemic, related research is being conducted on the need to prevent their spread; it is also necessary to develop more general physical–chemical control methods to manage them. Consequently, research has been carried out on light-emitting diodes (LEDs) as an effective means of light sterilization. In this study, the sterilization effects on four types of representative bacteria and mold that occur indoors, Bacillus subtilis, Escherichia coli, Penicillium chrysogenum, and Cladosporium cladosporidides, were confirmed using LED modules (with wavelengths of 275, 370, 385, and 405 nm). Additionally, power consumption was compared by calculating the time required for 99.9% sterilization of each microorganism. The results showed that the sterilization effect was high, in the order 275, 370, 385, and 405 nm. The sterilization effects at 385 and 405 nm were observed to be similar. Furthermore, when comparing the power consumption required for 99.9% sterilization of each microorganism, the 275 nm LED module required significantly less power than those of other wavelengths. However, at 405 nm, the power consumption required for 99.9% sterilization was less than that at 370 nm; that is, it was more efficient and similar to or less than that at 385 nm. Additionally, because 405 nm can be applied as general lighting, it was considered to have wider applicability and utility compared with UV wavelengths. Consequently, it should be possible to respond to infectious diseases in the environment using LEDs with visible light wavelengths.

4 February 2022 in Journal of Building Engineering
Verified
Journal Article
Closed access
JLJae-Hee Lee
Jae-Hee Lee
JBJONG IL BANG
JONG IL BANG
MSMinki Sung
Minki Sung
JAE-WEON JEONGJAE-WEON JEONG
JAE-WEON JEONG