Interconnection of microgrids (MGs) provides the opportunity of increasing loadability and enhancing reliability by allowing power exchange among individual MGs. Control of networked MGs requires coordination of distributed energy resources (DERs) within each MG such that the sum of the MG’s load and exported power is shared proportionally among DERs while maintaining power quality. This paper proposes a new hierarchical control scheme for accurate load sharing and power quality enhancement in networked MGs with unbalanced load currents. The proposed scheme is comprised of local DER controllers, MG control units, and Networked MG control center. The MG control units adjust the power exchange at the value specified by the control center and regulate the voltage at the point of common coupling (PCC) by means of a secondary control signal. At the DER level, droop control is adopted to enable load sharing with fast dynamic response. The droop controller output is combined with the secondary control signal and a correction voltage which eliminates the effect of line impedances on the current sharing accuracy. This way, accurate sharing of individual phase currents is realized without requirement of data exchange among DERs. Simulation and experimental results showcase the effectiveness of the proposed scheme.
18 February 2021 in IEEE Transactions on Smart Grid
The increasing penetration of dc distributed energy resources (DERs) and dc loads has motivated the utilization of dc microgrids (MGs). In this paper, a new two-level control scheme is proposed for accurate power sharing and appropriate voltage regulation in dc MGs during islanded operation mode. In the primary control level, a P-V̇ droop method is proposed to eliminate the dependency of power sharing among DERs on line resistances. Since the P-V̇ droop deviates the voltage derivative to a nonzero value, a voltage derivative restoration mechanism is adopted in the secondary control level to provide voltage stability. The secondary control level also compensates the voltage deviations by cascading an outer voltage control loop with the inner voltage derivative restoration loop. The secondary control signal is broadcasted to each DER via a unidirectional low-bandwidth communication link. Small signal stability of the proposed scheme is analyzed by studying the locus of the system eigenvalues. To verify the efficacy of the proposed method and compare it with the conventional scheme, real-time simulations in OPAL-RT lab setup are provided.
19 September 2022 in IEEE Transactions on Energy Conversion
The desire for decreasing the stress on the individual AC and DC sources motivates accurate load sharing in Hybrid AC/DC microgrids (HMGs). The conventional hierarchical control scheme suffers from error in active power sharing among the DC sources and inaccurate reactive power sharing in the AC microgrid, which result from the local property of voltage. To circumvent this issue, a unidirectional hierarchical control scheme, which employs a combination of central and local secondary controllers is proposed in this paper. For each of the DC and AC microgrids, the central secondary controller eliminates the voltage/frequency deviations through a common control signal, which is broadcasted to the sources and interlink converter (IC). In addition, the DC and AC PCC voltages are broadcasted to the sources and IC. The local secondary controller (power sharing correction unit) of each source alters the central secondary control signal based on the PCC voltage. By incorporation of the PCC voltage in the droop characteristics of the sources and the control loop of IC, the error in active/reactive power sharing is eliminated. The stability of the proposed scheme is analyzed through small signal analysis. Simulation and experimental results are presented to validate the proposed control method.
24 October 2023 in IEEE Transactions on Smart Grid
Hybrid single-phase ac/dc microgrids (MGs) consist of a dc MG and a single-phase ac MG, interconnected through an interlinking converter (IC). In this configuration, the dc MG naturally experiences a second harmonic current injection caused by the double-frequency component of the ac side instantaneous power. This paper proposes a new decentralized control method by utilization of the injected harmonic for power sharing. The proposed method enables accurate power sharing among dc sources and precise global power sharing among dc and ac sources without imposing any dc side voltage deviation. In this method, each dc source adjusts its power based on the frequency of the harmonic component. Additionally, the IC ensures that the voltage level of the dc MG remains at the rated value. Capacitive virtual impedances are integrated into the dc sources to facilitate second harmonic current sharing among them and prevent the circulation of harmonic current flow between the dc sources and the IC’s dc side capacitor. To fulfill the objectives, each dc source simultaneously regulates the second harmonic voltage of its output filter capacitor and the dc component current of its output filter inductor. The effectiveness of the proposed control strategy is demonstrated through time-domain and frequency-domain simulations.
This paper proposes an algorithm for detection and identification of the location of short circuit faults in islanded AC microgrids (MGs) with meshed topology. Considering the low level of fault current and dependency of the current angle on the control strategies, the legacy overcurrent protection schemes are not effective in in islanded MGs. To overcome this issue, the proposed algorithm detects faults based on the rms voltages of the distributed energy resources (DERs) by means of support vector machine classifiers. Upon detection of a fault, the DER which is electrically closest to the fault injects three interharmonic currents. The faulty zone is identified by comparing the magnitude of the interharmonic currents flowing through each zone. Then, the second DER connected to the faulty zone injects distinctive interharmonic currents and the resulting interharmonic voltages are measured at the terminal of each of these DERs. Using the interharmonic voltages as its features, a multi-class support vector machine identifies the fault location within the faulty zone. Simulations are conducted on a test MG to obtain a dataset comprising scenarios with different fault locations, varying fault impedances, and changing loads. The test results show that the proposed algorithm reliably detects the faults and the precision of fault location identification is above 90%.
Hybrid AC‐DC microgrids (HMGs) are formed by interconnecting AC microgrids (MGs) and DC microgrids via AC‐DC interlinking converters (ICs). In the islanded mode, apart from power sharing in a single MG, power sharing expansion throughout HMG is desirable. Conventionally, this is achieved by employing an IC control mechanism in coordination with the droop characteristics of sources. Because the conventional control strategy of IC relies on measuring the frequency variations in AC MG, accurate coordination necessitates a wide range of frequency deviation. Also, this strategy employs the current‐controlled method, which fails to accomplish superior voltage quality during load transients and in the presence of an unbalanced load obtainable by the voltage‐controlled method (VCM). An IC control strategy for single IC HMGs is proposed that does not require the measurement of frequency variation and employs VCM in the inner control loop. As a consequence, the power quality of AC MG is improved. The proposed control strategy is phase locked‐loop‐less. In addition, by supporting the related MG with the disconnection of sources in AC MG or DC MG, it provides a uniform control property. Time domain simulations and experimental results are provided to verify the efficacy of the proposed strategy.