Mahdi Shahparasti

Dr. Mahdi Shahparasti

University of Southern Denmark
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2014 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
Payam Teimourzadeh BaboliPayam Teimourzadeh Baboli
Payam Teimourzadeh Baboli
Mahdi ShahparastiMahdi Shahparasti
Mahdi Shahparasti
MMMohsen Parsa Moghaddam
Mohsen Parsa Moghaddam
MHMahmoud Reza Haghifam
Mahmoud Reza Haghifam
MMMustafa Mohamadian
Mustafa Mohamadian
Hybrid AC–DC microgrid is introduced as the future distribution network to utilise both benefits of alternative and direct currents. In such hybrid microgrid, AC and DC loads, renewable‐based distributed generators (DGs), controllable DGs and energy storage systems are connected through separate AC and DC links. An up–down operation model of such hybrid microgrid is proposed which consists of system‐ and device‐level. In the system‐level, a mixed integer linear model is suggested to balance the generation and load considering the interconnection of AC and DC subgrids for minimising total operating cost of the system in a 24‐hour period. In the device‐level, a controller is suggested for power converter‐based resources (i.e. intergrid inverter and battery) for controlling the voltage variations in AC and DC subgrids. The effectiveness of the proposed up–down operation model is demonstrated through simulation studies on a test hybrid microgrid.

18 November 2020 in IEEE Access
Verified
Journal Article
Open access
Jose RodriguezJose Rodriguez
Jose Rodriguez
RHRasool Heydari
Rasool Heydari
ZRZahra Rafiee
Zahra Rafiee
Hector YoungHector Young
Hector Young
Freddy Flores-BahamondeFreddy Flores-Bahamonde
Freddy Flores-Bahamonde
Mahdi ShahparastiMahdi Shahparasti
Mahdi Shahparasti
Conventional model predictive control (MPC) of power converter has been widely applied to power inverters achieving high performance, fast dynamic response, and accurate transient control of power converter. However, the MPC strategy is highly reliant on the accuracy of the inverter model used for the controlled system. Consequently, a parameter or model mismatch between the plant and the controller leads to a sub-optimal performance of MPC. In this paper, a new strategy called model-free predictive control (MF-PC) is proposed to improve such problems. The presented approach is based on a recursive least squares algorithm to identify the parameters of an auto-regressive with exogenous input (ARX) model. The proposed method provides an accurate prediction of the controlled variables without requiring detailed knowledge of the physical system. This new approach and is realized by employing a novel state space identification algorithm into the predictive control structure. The performance of the proposed model-free predictive control method is compared with conventional MPC. The simulation and experimental results show that the proposed method is totally robust against parameters and model changes compared with the conventional model based solutions.

14 March 2012 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
AFAlireza Fatemi
Alireza Fatemi
MAMahdi Azizi
Mahdi Azizi
MMMustafa Mohamadian
Mustafa Mohamadian
AVAli Yazdian Varjani
Ali Yazdian Varjani
Mahdi ShahparastiMahdi Shahparasti
Mahdi Shahparasti
In this paper, two reduced switch count topologies are introduced for independently supplying two single-phase ac loads with one inverter. Using a new three-switch leg structure recently introduced and implemented in three-phase converters, two types of dual-leg and single-leg topologies are developed which respectively are functionally comparable to two full-bridge and half-bridge inverters working independently though with a less number of semiconductor switches and hence control and gate drive circuit components. The proposed six-switch and three-switch topologies are introduced; two modes of equal frequency and different frequency operation each of its own distinctive characteristics are considered for them and their pulse width modulation schemes are elaborated. Comprehensive analyses of power loss profile and output waveform properties are conducted via simulation for the proposed inverters, and the results are compared with full-bridge and half-bridge inverters. To assess the performance of the proposed inverter topologies, working prototypes are built, and the experimental results are provided.

18 April 2022 in IEEE Access
Verified
Journal Article
Open access
Mahdi ShahparastiMahdi Shahparasti
Mahdi Shahparasti
Hannu LaaksonenHannu Laaksonen
Hannu Laaksonen
Kimmo KauhaniemiKimmo Kauhaniemi
Kimmo Kauhaniemi
PLPanu Lauttamus
Panu Lauttamus
SSStefan Strandberg
Stefan Strandberg
JSJan Strandberg
Jan Strandberg
This paper addresses the black start of medium voltage distribution networks (MV-DNs) by a battery energy storage system (BESS). The BESS consists of a two-level voltage source inverter interfacing MV-DN which has limited overcurrent capability. On the other hand, MV-DN normally includes several step-up and step-down transformers that are drawing sympathetic inrush current in energizing stage. Therefore, the major difficulty to perform black start by BESS during MV-DN island operation lies in the fact that the inverter has to simultaneous control the network voltage and its output current. This paper presents two control approaches for a BESS in order to control the inrush current during MV-DN black start. The proposed control schemes consist of droop, voltage and current loops in the stationary reference frame. The droop loop is used to generate the voltage reference. An intermediate voltage and inner current loops are designed for output voltage regulation, current reference generation as well as current tracking, respectively. New reference modifiers are included into droop and voltage loops to limit inrush current. The proposed control schemes are experimentally tested for energizing Ingå MV-DN in Finland by 1 MVA BESS, and their performance is compared in terms of inrush current value and voltage quality. The obtained results prove that both methods are able to feed the load with a fixed voltage in the steady-state as well as to limit the transformer inrush current considering the inverter overcurrent limit.

1 November 2013 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Mahdi ShahparastiMahdi Shahparasti
Mahdi Shahparasti
MMMustafa Mohamadian
Mustafa Mohamadian
AYAli Yazdian
Ali Yazdian
AAAhmad Ale Ahmad
Ahmad Ale Ahmad
MAMassoud Amini
Massoud Amini
In this paper, a stationary-frame, single-loop controller for three-phase standalone inverter supplying nonlinear loads has been derived from synchronous reference frame proportional-integral multiloop controller. In this method, load voltage harmonics are eliminated by a single loop and only one control variable. The proposed method has several advantages such as lack of Park transformation and requires tuning only one control parameter. It can also be implemented with less computational burden, less complexity, and easier tuning, compared to conventional proportional-integral multiloop controller. Experimental results with laboratory prototype under linear and nonlinear load conditions validate the proposed method.

18 February 2021 in IEEE Transactions on Smart Grid
Verified
Journal Article
Open access
MBMehdi Baharizadeh
Mehdi Baharizadeh
MGMohammad S. Golsorkhi
Mohammad S. Golsorkhi
Mahdi ShahparastiMahdi Shahparasti
Mahdi Shahparasti
Mehdi SavaghebiMehdi Savaghebi
Mehdi Savaghebi
The increasing penetration of dc distributed energy resources (DERs) and dc loads has motivated the utilization of dc microgrids (MGs). In this paper, a new two-level control scheme is proposed for accurate power sharing and appropriate voltage regulation in dc MGs during islanded operation mode. In the primary control level, a P-V̇ droop method is proposed to eliminate the dependency of power sharing among DERs on line resistances. Since the P-V̇ droop deviates the voltage derivative to a nonzero value, a voltage derivative restoration mechanism is adopted in the secondary control level to provide voltage stability. The secondary control level also compensates the voltage deviations by cascading an outer voltage control loop with the inner voltage derivative restoration loop. The secondary control signal is broadcasted to each DER via a unidirectional low-bandwidth communication link. Small signal stability of the proposed scheme is analyzed by studying the locus of the system eigenvalues. To verify the efficacy of the proposed method and compare it with the conventional scheme, real-time simulations in OPAL-RT lab setup are provided.