Drift compensation is an important issue for metal oxide semiconductor (MOS) gas sensor arrays. General machine learning methods require constant calibration and a large amount of label gas data. At the same time, recalibration will cause a lot of costs, and label gas is difficult to obtain in practice. In this paper, a novel drift compensation method based on balanced distribution adaptation (BDA) is proposed. First, the BDA drift compensation method can adjust the conditional distribution and marginal distribution between the two domains through the weight balance factor, thereby more effectively reducing the mismatch between the two domains. When the BDA method performs classification tasks through machine learning, no labeled data is required in the target domain. Then, the particle swarm optimization algorithm is used to improve the accuracy of drift compensation. Individuals in the population are initialized randomly, and their fitness values are calculated. Iterative optimization of the population individuals is conducted until the optimal weight balance factor parameters are calculated. Finally, the BDA method is experimentally verified on the public gas sensor drift data set. Experimental results showed that the BDA method was significantly better than the existing joint distribution adaptation (JDA) method and other standard drift compensation methods such as K-Nearest Neighbor (KNN). In the two setting groups, the recognition accuracy was 4.54% and 1.62% ahead of the JDA method, and 12.23% and 15.83% ahead of the KNN method.
As an auxiliary function of the wireless power transfer (WPT) system, coil positioning can solve the power and efficiency degradation during power transmission caused by misalignment of the magnetic coupler. In this paper, a Hall sensor array is used to measure the change of magnetic flux density. By comparing the multisensor data fusion results with the preset data obtained from the coil alignment, the real-time accurate positioning of the receiving coil can be realized. Firstly, the positioning model of the receiving coil is built and the variation of magnetic flux density with the coil misalignment is analyzed. Secondly, the arrangement of the Planar 8-direction symmetric sensor array and the positioning algorithm based on data fusion of magnetic flux density variations are proposed. In order to avoid coil positioning misalignment caused by the unstable magnetic field distribution which is actually affected by the change of mutual inductance during automatic guided vehicle (AGV) alignment, the constant current strategy of primary and secondary sides is proposed. Finally, the coil positioning experimental platform is built. The experimental results show that the coil positioning method proposed in this paper has high accuracy, and the positioning error is within 4 cm.
This study presents a two-dimensional micro-/nanoradian angle generator (2D-MNAG) that achieves high angular displacement resolution and repeatability using a piezo-driven flexure hinge for two-dimensional deflections and three capacitive sensors for output angle monitoring and feedback control. The principal error of the capacitive sensor for precision microangle measurement is analyzed and compensated for; so as to achieve a high angle output resolution of 10 nrad (0.002 arcsec) and positioning repeatability of 120 nrad (0.024 arcsec) over a large angular range of ±4363 μrad (±900 arcsec) for the 2D-MNAG. The impact of each error component, together with the synthetic error of the 2D-MNAG after principal error compensation are determined using Monte Carlo simulation for further improvement of the 2D-MNAG.
A circular grating angle encoder is a key component in the dynamic torque calibration system. To improve the accuracy of an angle measurement, in this paper, the source of the angle measurement error of the circular grating is analyzed; an eccentricity error model and an inclination error model are proposed, respectively; further, these two models are combined to establish a total error model. Through the simulation study with the models, the conditions, in which the eccentricity error or inclination error can be ignored, are discussed. The calibration and compensation methods of the angle measurement error are given, and a progressive error compensation function which integrates the first harmonic fitting and the second harmonic fitting is obtained. An experiment is performed to verify the proposed calibration and compensation methods. The peak-to-peak value of the compensated angle measurement error of the single reading head can be reduced by about 93.76%, which approximates to the error of the mean value of the double reading heads. The experimental results show that the error calibration and compensation method based on the proposed error model can effectively compensate the angle measurement error of the circular grating with a single reading head, and obtain a high-precision measurement angle.
The relative positioning precisions of coordinate points is an important indicator that affects the final accuracy in the visual measurement system of space cooperative targets. Many factors, such as measurement methods, environmental conditions, data processing principles and equipment parameters, are supposed to influence the cooperative target’s acquisition and determine the precision of the cooperative target’s position in a ground simulation experiment with laser projected spots on parallel screens. To overcome the precision insufficiencies of cooperative target measurement, the factors of the laser diode supply current and charge couple device (CCD) camera exposure time are studied in this article. On the hypothesis of the optimal experimental conditions, the state equations under the image coordinates’ system that describe the laser spot position’s variation are established. The novel optimizing method is proposed by taking laser spot position as state variables, diode supply current and exposure time as controllable variables, calculating the optimal controllable variables through intersecting the focal spot centroid line and the 3-D surface, and avoiding the inconvenience of solving nonlinear equations. The experiment based on the new algorithm shows that the optimal solution can guarantee the focal spot’s variation range in 5–10 pixels under image coordinates’ system equivalent to the space with a 3 m distance and 0.6–1.2 mm positioning accuracy.
11 September 2025 in Computer Methods and Programs in Biomedicine