Yasuko Kitajima

Prof. Yasuko Kitajima

Tokyo Ariake University of Medical and Health Sciences
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2014 in IEEE Transactions on Learning Technologies
Verified
Journal Article
Open access
ZHZhifeng Huang
Zhifeng Huang
ANAyanori Nagata
Ayanori Nagata
MKMasako Kanai-Pak
Masako Kanai-Pak
JMJukai Maeda
Jukai Maeda
YKYasuko Kitajima
Yasuko Kitajima
JOJun Ota
Jun Ota
This paper describes the construction and evaluation of a self-help skill training system for assisting student nurses in learning skills involving the transfer of patients from beds to wheelchairs. We have proposed a feedback method that is based on a checklist and video demonstrations. To help trainees efficiently check their performance and correct errors, the checklist was prepared with items specific to the performance of tasks related to individual body parts (e.g., the height of the waist). In this system, two Kinect RGB-D sensors were used for measuring the posture of the trainees and patients. An automatic skill evaluation method was used to designate the trainees' performance against each evaluation item as correct or incorrect. Furthermore, the system's operation interface was designed to enable self-operation by trainees. Control tests were performed to measure the training effectiveness of the system. The results of the tests on a control group (n = 5) that used only a textbook and demonstration video but did not receive feedback were compared with those of the experimental group (n = 5) that used the proposed system. The results of both subjective and objective evaluation demonstrated that the experimental group showed greater improvement in performing patient transfer than the control group (p <; 0:05).

23 July 2020 in International Journal of Social Robotics
Verified
Journal Article
Open access
PDF file
CLCHINGSZU LIN
CHINGSZU LIN
TOTaiki Ogata
Taiki Ogata
ZZZhihang Zhong
Zhihang Zhong
MKMasako Kanai-Pak
Masako Kanai-Pak
JMJukai Maeda
Jukai Maeda
JOJun Ota
Jun Ota
To more efficiently enhance the patient transfer skills of nursing students, this study aims to integrate a transfer skills evaluation system and a robot patient. The evaluation parameters, namely, the translational acceleration of the waist, rotational speed of the chest, and joint angles of the shoulder, hip, and knee, were selected on the basis of the pre-experimental results obtained with a simulated patient acted by the human individuals. To measure these parameters, inertial measurement unit (IMU) and angular position sensors were installed on the robot patient. An experiment was conducted with four nursing teachers to verify whether the robot patient could distinguish the incorrect methods of the transfer skills, determined to be a common mistake made by the nurses. According to the results, most transfer steps had the same effect on the simulated patient and the robot patient, which demonstrates that the robot patient is a suitable substitute for an actual patient. However, in certain steps, the robot patient was not able to distinguish between the correct and incorrect methods using the chosen parameters owing to the differences being insignificant. These insignificant differences were mostly attributed to the passive joint design of the robot patient.

23 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CLCHINGSZU LIN
CHINGSZU LIN
TOTaiki Ogata
Taiki Ogata
ZZZhihang Zhong
Zhihang Zhong
MKMasako Kanai-Pak
Masako Kanai-Pak
JMJukai Maeda
Jukai Maeda
JOJun Ota
Jun Ota
Recently, human patient simulators have been widely developed as substitutes for real patients with the objective of applying them as training tools in nursing education. Such simulated training is perceived as beneficial for imparting the required practical skills to students. Considering the aging world population, this study aimed to develop a robot patient for training nursing students in the sit-to-stand (STS) transfer skill, which is indispensable in caring for elderly people. To assess a student’s skill, the robot patient should be able to access the skill correctness and behave according to whether the skill is correctly or incorrectly implemented. Accordingly, an STS control method was proposed to reproduce the different STS movements during correct and incorrect applications of the skill by the nurses. The lower limbs of a prototype robot were redesigned to provide an active joint with a compliant unit, which enables the measurement of external torque and flexibility of the human joint to be reproduced. An experiment was conducted with four nurse teachers, each of whom was asked to demonstrate both correct and incorrect STS transfer skills. The results of the external torque and joint torque measured in robot’s lower limbs revealed that a significant difference (p < 0.05) between correct and incorrect skills. It also indicates the introduction of the proposed control method for the robot can satisfy the requirement of the assessment of STS skill. Among the various measurements conducted, the external torque of the hip joint exhibited the most significant difference and therefore represented the most robust measure for assessing whether the STS transfer skill was correctly applied.

6 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
CLCHINGSZU LIN
CHINGSZU LIN
MKMasako Kanai-Pak
Masako Kanai-Pak
JMJukai Maeda
Jukai Maeda
YKYasuko Kitajima
Yasuko Kitajima
MNMitsuhiro Nakamura
Mitsuhiro Nakamura
JOJun Ota
Jun Ota
Currently, due to shortages in the nursing faculty and low access to actual patients, it is difficult for students to receive feedback from teachers and practice with actual patients to obtain clinic experience. Thus, both evaluation systems and simulated patients have become urgent requirements. Accordingly, this study proposes a method to evaluate the nurse’s transfer skill through observation from the patient. After verifying the proposed method, it will be integrated with a robotic patient as a future work. To verify if such an evaluation is practical, a checklist comprising 16 steps with correct and incorrect methods was proposed by the nursing teachers. Further, the evaluation parameters were determined as translational acceleration, rotational speed, and joint angle of patient. Inertial sensors and motion capture were employed to measure the translational acceleration, rotational speed, and joint angle. An experiment was conducted with two nursing teachers, who were asked to carry out both correct and incorrect methods. According to the results, three parameters reveal the difference for a patient under correct/incorrect methods and can further be used to evaluate the nurse’s skill once the thresholds are determined. In addition, the applicability of inertial sensors is confirmed for the use of robot development.


14 May 2017
Verified
Book Chapter
Closed access
PDF file
YKYasuko Kitajima
Yasuko Kitajima
YTYuka Takai
Yuka Takai
KYKazuaki Yamashiro
Kazuaki Yamashiro
YOYoichiro Ogura
Yoichiro Ogura
AGAkihiko Goto
Akihiko Goto