Mototaka Miyake

Dr. Mototaka Miyake

National Cancer Center Hospital

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2020 in Cancers
Verified
Journal Article
Open access
PDF file
Ryuji HamamotoRyuji Hamamoto
Ryuji Hamamoto
KSKruthi Suvarna
Kruthi Suvarna
MYMasayoshi Yamada
Masayoshi Yamada
KKKazuma Kobayashi
Kazuma Kobayashi
NSNorio Shinkai
Norio Shinkai
SKSyuzo Kaneko
Syuzo Kaneko
In recent years, advances in artificial intelligence (AI) technology have led to the rapid clinical implementation of devices with AI technology in the medical field. More than 60 AI-equipped medical devices have already been approved by the Food and Drug Administration (FDA) in the United States, and the active introduction of AI technology is considered to be an inevitable trend in the future of medicine. In the field of oncology, clinical applications of medical devices using AI technology are already underway, mainly in radiology, and AI technology is expected to be positioned as an important core technology. In particular, “precision medicine,” a medical treatment that selects the most appropriate treatment for each patient based on a vast amount of medical data such as genome information, has become a worldwide trend; AI technology is expected to be utilized in the process of extracting truly useful information from a large amount of medical data and applying it to diagnosis and treatment. In this review, we would like to introduce the history of AI technology and the current state of medical AI, especially in the oncology field, as well as discuss the possibilities and challenges of AI technology in the medical field.

19 March 2021 in Cancers
Verified
Journal Article
Open access
PDF file
STsatoshi takahashi
satoshi takahashi
Masamichi TakahashiMasamichi Takahashi
Masamichi Takahashi
Manabu KinoshitaManabu Kinoshita
Manabu Kinoshita
MMMototaka Miyake
Mototaka Miyake
RKRisa Kawaguchi
Risa Kawaguchi
Ryuji HamamotoRyuji Hamamoto
Ryuji Hamamoto
Machine learning models for automated magnetic resonance image segmentation may be useful in aiding glioma detection. However, the image differences among facilities cause performance degradation and impede detection. This study proposes a method to solve this issue. We used the data from the Multimodal Brain Tumor Image Segmentation Benchmark (BraTS) and the Japanese cohort (JC) datasets. Three models for tumor segmentation are developed. In our methodology, the BraTS and JC models are trained on the BraTS and JC datasets, respectively, whereas the fine-tuning models are developed from the BraTS model and fine-tuned using the JC dataset. Our results show that the Dice coefficient score of the JC model for the test portion of the JC dataset was 0.779 ± 0.137, whereas that of the BraTS model was lower (0.717 ± 0.207). The mean Dice coefficient score of the fine-tuning model was 0.769 ± 0.138. There was a significant difference between the BraTS and JC models (p < 0.0001) and the BraTS and fine-tuning models (p = 0.002); however, no significant difference between the JC and fine-tuning models (p = 0.673). As our fine-tuning method requires fewer than 20 cases, this method is useful even in a facility where the number of glioma cases is small.

1 December 2021 in Medical Image Analysis
Verified
Journal Article
Open access
KKKazuma Kobayashi
Kazuma Kobayashi
RHRyuichiro Hataya
Ryuichiro Hataya
YKYusuke Kurose
Yusuke Kurose
MMMototaka Miyake
Mototaka Miyake
Masamichi TakahashiMasamichi Takahashi
Masamichi Takahashi
Ryuji HamamotoRyuji Hamamoto
Ryuji Hamamoto
In medical imaging, the characteristics purely derived from a disease should reflect the extent to which abnormal findings deviate from the normal features. Indeed, physicians often need corresponding images without abnormal findings of interest or, conversely, images that contain similar abnormal findings regardless of normal anatomical context. This is called comparative diagnostic reading of medical images, which is essential for a correct diagnosis. To support comparative diagnostic reading, content-based image retrieval (CBIR) that can selectively utilize normal and abnormal features in medical images as two separable semantic components will be useful. In this study, we propose a neural network architecture to decompose the semantic components of medical images into two latent codes: normal anatomy code and abnormal anatomy code. The normal anatomy code represents counterfactual normal anatomies that should have existed if the sample is healthy, whereas the abnormal anatomy code attributes to abnormal changes that reflect deviation from the normal baseline. By calculating the similarity based on either normal or abnormal anatomy codes or the combination of the two codes, our algorithm can retrieve images according to the selected semantic component from a dataset consisting of brain magnetic resonance images of gliomas. Moreover, it can utilize a synthetic query vector combining normal and abnormal anatomy codes from two different query images. To evaluate whether the retrieved images are acquired according to the targeted semantic component, the overlap of the ground-truth labels is calculated as metrics of the semantic consistency. Our algorithm provides a flexible CBIR framework by handling the decomposed features with qualitatively and quantitatively remarkable results.

12 April 2021 in Biomolecules
Verified
Journal Article
Open access
PDF file
STsatoshi takahashi
satoshi takahashi
Masamichi TakahashiMasamichi Takahashi
Masamichi Takahashi
STShota Tanaka
Shota Tanaka
STShunsaku Takayanagi
Shunsaku Takayanagi
HTHirokazu Takami
Hirokazu Takami
Ryuji HamamotoRyuji Hamamoto
Ryuji Hamamoto
Although the incidence of central nervous system (CNS) cancers is not high, it significantly reduces a patient’s quality of life and results in high mortality rates. A low incidence also means a low number of cases, which in turn means a low amount of information. To compensate, researchers have tried to increase the amount of information available from a single test using high-throughput technologies. This approach, referred to as single-omics analysis, has only been partially successful as one type of data may not be able to appropriately describe all the characteristics of a tumor. It is presently unclear what type of data can describe a particular clinical situation. One way to solve this problem is to use multi-omics data. When using many types of data, a selected data type or a combination of them may effectively resolve a clinical question. Hence, we conducted a comprehensive survey of papers in the field of neuro-oncology that used multi-omics data for analysis and found that most of the papers utilized machine learning techniques. This fact shows that it is useful to utilize machine learning techniques in multi-omics analysis. In this review, we discuss the current status of multi-omics analysis in the field of neuro-oncology and the importance of using machine learning techniques.

19 July 2021 in Cancers
Verified
Journal Article
Open access
PDF file
RKRisa Kawaguchi
Risa Kawaguchi
Masamichi TakahashiMasamichi Takahashi
Masamichi Takahashi
MMMototaka Miyake
Mototaka Miyake
Manabu KinoshitaManabu Kinoshita
Manabu Kinoshita
STsatoshi takahashi
satoshi takahashi
JSJun Sese
Jun Sese
Radiogenomics use non-invasively obtained imaging data, such as magnetic resonance imaging (MRI), to predict critical biomarkers of patients. Developing an accurate machine learning (ML) technique for MRI requires data from hundreds of patients, which cannot be gathered from any single local hospital. Hence, a model universally applicable to multiple cohorts/hospitals is required. We applied various ML and image pre-processing procedures on a glioma dataset from The Cancer Image Archive (TCIA, n = 159). The models that showed a high level of accuracy in predicting glioblastoma or WHO Grade II and III glioma using the TCIA dataset, were then tested for the data from the National Cancer Center Hospital, Japan (NCC, n = 166) whether they could maintain similar levels of high accuracy. Results: we confirmed that our ML procedure achieved a level of accuracy (AUROC = 0.904) comparable to that shown previously by the deep-learning methods using TCIA. However, when we directly applied the model to the NCC dataset, its AUROC dropped to 0.383. Introduction of standardization and dimension reduction procedures before classification without re-training improved the prediction accuracy obtained using NCC (0.804) without a loss in prediction accuracy for the TCIA dataset. Furthermore, we confirmed the same tendency in a model for IDH1/2 mutation prediction with standardization and application of dimension reduction that was also applicable to multiple hospitals. Our results demonstrated that overfitting may occur when an ML method providing the highest accuracy in a small training dataset is used for different heterogeneous data sets, and suggested a promising process for developing an ML method applicable to multiple cohorts.

22 September 2006 in Radiation Medicine
Verified
Journal Article
Closed access
PDF file
MMMototaka Miyake
Mototaka Miyake
UTUkihide Tateishi
Ukihide Tateishi
TMTetsuo Maeda
Tetsuo Maeda
YAYasuaki Arai
Yasuaki Arai
KSKunihiko Seki
Kunihiko Seki
KSKazuro Sugimura
Kazuro Sugimura