The widespread use of single-use polypropylene packaging for sterilization of surgical instruments (blue wrap) results in enormous environmental pollution and plastic waste, estimated at 115 million kilograms on a yearly basis in the United States alone. Rigid sterilization containers (RSCs) are a well-known alternative in terms of quality and price. This paper deals with two research questions investigating the following aspects: (A) the environmental advantage of RCS for high volumes (5000 use cycles) in big hospitals, and (B) the environmental break-even point of use-cycles for small hospitals. An in-depth life cycle assessment was used to benchmark the two systems. As such a benchmark is influenced by the indicator system, three indicator systems were applied: (a) carbon footprint, (b) ReCiPe, and (c) eco-costs. The results are as follows: (1) the analyzed RSC has 85% less environmental impact in carbon footprint, 52% in ReCiPe, and 84.5% in eco-costs; and (2) an ecological advantage already occurs after 98, 228, and 67 out of 5000 use cycles, respectively. Given these two alternative packaging systems with comparable costs and quality, our results show that there are potentially large environmental gains to be made when RSC is preferred to blue wrap as a packaging system for sterile surgical instruments on a global scale.
The purpose of this study was to describe a new method to effectively improve the environmental impact of operating rooms through a systematic approach. A proven successful prospective risk analysis tool to improve the safety of complex healthcare processes (Healthcare Failure Mode and Effect Analysis) was adapted to reduce the environmental impact of surgical waste. For this novel method, named the Healthcare Sustainability Mode and Effect Analysis (HSMEA), a multidisciplinary team, using a structured step-by-step approach, systematically inventories surgical waste, quantifies its environmental impacts, identifies hotspots, and provides solutions for improvement. The five steps of the HSMEA are described (definition of the topic, team assembly, flowchart creation, hazard analysis, actions and outcome measures) and the surgical procedure of a caesarean section was used as a case study to assess the applicability of this method to improve its environmental impact. Applying the HSMEA to caesarean sections resulted in a 22% volume reduction and a 22% carbon footprint reduction in surgical waste. This was achieved by revising the disposable custom pack in order to reduce the overage that was present, and by intensifying waste stream segregation for plastic and paper recycling. The HSMEA is a practical work floor tool to aid in the reduction of the environmental impact of surgical waste that is applicable to all types of operations. It is reproducible, and because it identifies carbon hotspots, it enables an efficient approach to the issue of operating room pollution.
Surgical site infection (SSI) in the form of postoperative deep sternal wound infection (DSWI) after cardiac surgery is a rare, but potentially fatal, complication. In addressing this, the focus is on preventive measures, as most risk factors for SSI are not controllable. Therefore, operating rooms are equipped with heating, ventilation and air conditioning (HVAC) systems to prevent airborne contamination of the wound, either through turbulent mixed air flow (TMA) or unidirectional air flow (UDAF). To investigate if the risk for SSI after cardiac surgery was decreased after changing from TMA to UDAF. This observational retrospective single-centre cohort study collected data from 1288 patients who underwent open heart surgery over 2 years. During the two study periods, institutional SSI preventive measures remained the same, with the exception of the type of HVAC system that was used. Using multi-variable logistic regression analysis that considered confounding factors (diabetes, obesity, duration of surgery, and re-operation), the hypothesis that TMA is an independent risk factor for SSI was rejected (odds ratio 0.9, 95% confidence interval 0.4-1.8; P>0.05). It was not possible to demonstrate the preventive effect of UDAF on the incidence of SSI in patients undergoing open heart surgery when compared with TMA. Based on these results, the use of UDAF in open heart surgery should be weighed against its low cost-effectiveness and negative environmental impact due to high electricity consumption. Reducing energy overuse by utilizing TMA for cardiac surgery can diminish the carbon footprint of operating rooms, and their contribution to climate-related health hazards.
Annually, over 300 million surgeries occur globally, requiring numerous surgical instruments. However, many instruments on the tray are returned to the central sterile supply department (CSSD) unused, creating an unsustainable pattern of unnecessary consumption. To address this, we developed a method for optimising surgical instrument trays (SITs) that is straightforward to implement in other hospitals. This optimisation aims to enhance patient safety and sustainability and to improve working conditions and reduce costs. We identified actual instrument usage (IU) in the operating room (OR) and obtained expert recommendations (ERs). Data from both methods were combined in a computer model (CM) to adjust the SITs. The performance of the adjusted SITs was assessed over a year. IU of three different SITs was collected during 16 procedures (mean = 28.4%, SD = 6.4%). Combining IU and ERs resulted in a 36.7% reduction in instruments and a 31.3% weight reduction. These measures contribute to reducing the carbon footprint and enhancing sustainability. During the evaluation of the new SIT contents (n = 7 procedures), mean IU increased from 28.4% (SD = 6.4%) to 46.5% (SD = 11.0%), with no missing instruments during surgery. A one-year follow-up showed no need for further alterations. Combining both methods yields better results than using them individually, efficiently reducing unnecessary items in SITs without compromising patient safety.
16 December 2024 in European Journal of Anaesthesiology Intensive Care
BACKGROUND: Anaesthetic gases are an important source of greenhouse gas emissions from operating theatres and can attribute significantly to the carbon footprint of a nation's healthcare system. OBJECTIVE: To estimate the magnitude of the climate impact of inhaled anaesthetics in the Netherlands. Furthermore, the goal was to assess the preferences of Dutch anaesthesiologists for anaesthesia techniques, and to explore opportunities for reducing greenhouse gas emissions due to anaesthesia practice. DESIGN: A 2019 bottom-up purchase analysis of inhalation anaesthetics used in all of the Dutch hospitals was executed and an online survey was conducted among Dutch anaesthesiologists regarding their preferences for anaesthetic agents. RESULTS: Purchasing quantities of volatile anaesthetic agents were obtained from 61 of the 69 hospital organisations in the Netherlands (response rate 88.4%). A total of 12.2 kilotons CO2 equivalent (0.07% of the Dutch healthcare system) was emitted due to inhalation anaesthetics in the Netherlands in 2019. The volume of the in 2019 purchased inhalation volatile anaesthetics was 9.178 l of sevoflurane (93.4%), 404 l of desflurane (4.1%) and 245 l of isoflurane (2.5%). The survey in which 182 anaesthesiologists participated demonstrated that propofol was the first drug of choice of 70% of respondents, desflurane was available in 16% of Dutch hospitals and 83% of anaesthesiologists answered never using desflurane. Nitrous oxide was not used by 63% of respondents, the remaining 27% reported using nitrous oxide only in less than 5% of their cases. CONCLUSION: The relatively low emission of greenhouse gases due to inhalation anaesthetics in Dutch healthcare compared to other countries can be explained by the limited use of nitrous oxide and desflurane by Dutch anaesthesiologists and their strong preference for intravenously administered propofol as an anaesthetic.