Peng Zhang

Mr. Peng Zhang

Harbin University of Science and technology

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Science of The Total Environment
Verified
Journal Article
Closed access
MWMeixuan Wu
Meixuan Wu
ZZZiyu Zhao
Ziyu Zhao
PZPeng Zhang
Peng Zhang
MWMingding Wan
Mingding Wan
JLJilin Lei
Jilin Lei
Baoshan XingBaoshan Xing
Baoshan Xing

20 April 2023 in Journal of Environmental Management
Verified
Journal Article
Closed access
XZXingyuan Zhang
Xingyuan Zhang
JTJiayi Tao
Jiayi Tao
FLFang Lei
Fang Lei
Tao SunTao Sun
Tao Sun
LLLijin Lin
Lijin Lin
HLHongliang Li
Hongliang Li

1 October 2020 in Environmental Pollution
Verified
Journal Article
Open access
YZYing Zhou
Ying Zhou
YSYijun Shao
Yijun Shao
YYYue Yuan
Yue Yuan
JIAN LIUJIAN LIU
JIAN LIU
XZXiaoli Zou
Xiaoli Zou
GDGeorge S. Downward
George S. Downward
Air pollution is a major public health challenge in the highly urbanized megacities of China. However, knowledge on exposure to ambient unregulated air pollutants such as black carbon (BC) and ultrafine particles (UFP) among the Chinese population, especially among urban high school students who may have highly variable time-activity patterns, is scarce. To address this, the personal exposures to BC and UFP of high school students (aged 17 to 18) in Chengdu, China were measured at 1-min intervals via portable samplers. Monitoring lasted for 2 consecutive 24-h periods with days classified as "school days" or "non-school days". Time-activity diaries and measurements were combined to explore spatial, temporal, and behavioral factors that contribute to different exposure profiles. The overall geometric means of BC and UFP were 3.60 μg/m3 and 1.83 × 104p/cm3, respectively with notable spatiotemporal variation in exposures observed. In general, the household and transport microenvironments were the predominant contributors to total BC (74.5%) and UFP (36.5%) exposure. However, the outdoor public microenvironment was found to have significantly higher overall average levels of BC than the household and transport microenvironments (p < 0.001) while also presenting the greatest exposure dose intensity (EDI - a measure of exposure in a microenvironment in proportion to time spent in that environment) of 4.79. The largest overall average level of UFP occurred in the indoor public microenvironment followed by transport. The outdoor public microenvironment also presented the greatest EDI of UFP (4.17). This study shows notable spatiotemporal variety in exposure patterns and will inform future exposure and population health studies. The high EDI outdoors may mean that health positive activities, such as exercise, may be being undermined by ambient pollution.

Verified
Journal Article
Open access
PDF file
QLQishun Li
Qishun Li
Yanpeng HaoYanpeng Hao
Yanpeng Hao
PZPeng Zhang
Peng Zhang
HTHaotian Tan
Haotian Tan
WTWanxing Tian
Wanxing Tian
LYLin Yang
Lin Yang
Local scouring might result in the spanning of submarine cables, endangering their mechanical and electrical properties. In this contribution, a three-dimensional computational fluid dynamics simulation model is developed using FLOW-3D, and the scouring process of semi-exposed submarine cables is investigated. The effects of the sediment critical Shields number, sediment density, and ocean current velocity on local scouring are discussed, and variation rules for the submarine cables’ spanning time are provided. The results indicate that three scouring holes are formed around the submarine cables. The location of the bottom of the holes corresponds to that of the maximum shear velocity. The continuous development of scouring holes at the wake position leads to the spanning of the submarine cables. The increase in the sediment’s critical Shields number and sediment density, as well as the decrease in the ocean current velocity, will extend the time for maintaining the stability of the upstream scouring hole and retard the development velocity of the wake position and downstream scouring holes. The spanning time has a cubic relationship with the sediment’s critical Shields number, a linear relationship with the sediment density, and an exponential relationship with the ocean current velocity. In this paper, the local scouring process of semi-exposed submarine cables is studied, which provides a theoretical basis for the operation and maintenance of submarine cables.

25 March 2021 in Materials
Verified
Journal Article
Open access
PDF file
PZPeng Zhang
Peng Zhang
YZYongQi Zhang
YongQi Zhang
XWxuan wang
xuan wang
Jiaming YangJiaming Yang
Jiaming Yang
WHWenbin Han
Wenbin Han
Blending thermoplastic elastomers into polypropylene (PP) can make it have great potential for high-voltage direct current (HVDC) cable insulation by improving its toughness. However, when a large amount of thermoplastic elastomer is blended, the electrical strength of PP will be decreased consequently, which cannot meet the electrical requirements of HVDC cables. To solve this problem, in this paper, the inherent structure of thermoplastic elastomer SEBS was used to construct acetophenone structural units on its benzene ring through Friedel–Crafts acylation, making it a voltage stabilizer that can enhance the electrical strength of the polymer. The DC electrical insulation properties and mechanical properties of acetylated SEBS (Ac-SEBS)/PP were investigated in this paper. The results showed that by doping 30% Ac-SEBS into PP, the acetophenone structural unit on Ac-SEBS remarkably increased the DC breakdown field strength of SEBS/PP by absorbing high-energy electrons. When the degree of acetylation reached 4.6%, the DC breakdown field strength of Ac-SEBS/ PP increased by 22.4% and was a little higher than that of PP. Ac-SEBS, with high electron affinity, is also able to reduce carrier mobility through electron capture, resulting in lower conductivity currents in SEBS/PP and suppressing space charge accumulation to a certain extent, which enhances the insulation properties. Besides, the highly flexible Ac-SEBS can maintain the toughening effect of SEBS, resulting in a remarkable increase in the tensile strength and elongation at the break of PP. Therefore, Ac-SEBS/PP blends possess excellent insulation properties and mechanical properties simultaneously, which are promising as insulation materials for HVDC cables.

16 October 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
PZPeng Zhang
Peng Zhang
Yanpeng HaoYanpeng Hao
Yanpeng Hao
ZSZikui Shen
Zikui Shen
HTHaotian Tan
Haotian Tan
LLLicheng Li
Licheng Li
The application prospects of fiber optic Mach-Zehnder Interferometer (MZI) acousto-sensing technology in the field of partial discharge detection are promising. However, current external fiber optic sensors are not sensitive enough to effectively detect partial discharges. There is an urgent need to increase sensor sensitivity. In this paper, a power-function-curved mandrel sensor (PMS) with an acoustic wave enhancement function was developed, and a fiber MZI acoustic wave sensing system was built. Based on the standard sinusoidal signal, the amplitude and frequency response characteristics of the sensor were measured, and the influence of the mandrel curved surface length on the system sensitivity was studied. The results show that the PMS possesses enhanced acousto-sensing effects. When driven by a piezoelectric transducer emitting 40 kHz acoustic waves at 0.36 V, the PMS achieved the lowest detection threshold of the system, which is 0.44 V lower than that of the cylindrical mandrel sensor (CMS). In the 2-60 kHz frequency range, the sensitivity of the PMS is 41.0% higher than that of the CMS, with an average sensitivity increase of 50.4%. At low frequencies, the signal-to-noise ratio of the sensor improves with an increase in the length of the mandrel curved surface. Finally, the effectiveness of the sensing system for detecting rod-rod electrode discharges was tested. It was found that response peak-to-peak value of the PMS is higher than that of the CMS, proving that the acoustic sensing system can be used for external sensing of power equipment discharges.