Local scouring might result in the spanning of submarine cables, endangering their mechanical and electrical properties. In this contribution, a three-dimensional computational fluid dynamics simulation model is developed using FLOW-3D, and the scouring process of semi-exposed submarine cables is investigated. The effects of the sediment critical Shields number, sediment density, and ocean current velocity on local scouring are discussed, and variation rules for the submarine cables’ spanning time are provided. The results indicate that three scouring holes are formed around the submarine cables. The location of the bottom of the holes corresponds to that of the maximum shear velocity. The continuous development of scouring holes at the wake position leads to the spanning of the submarine cables. The increase in the sediment’s critical Shields number and sediment density, as well as the decrease in the ocean current velocity, will extend the time for maintaining the stability of the upstream scouring hole and retard the development velocity of the wake position and downstream scouring holes. The spanning time has a cubic relationship with the sediment’s critical Shields number, a linear relationship with the sediment density, and an exponential relationship with the ocean current velocity. In this paper, the local scouring process of semi-exposed submarine cables is studied, which provides a theoretical basis for the operation and maintenance of submarine cables.
Due to current scouring, submarine cables are prone to be exposed, suspended, and even vortex-induced vibration, which is not conducive to the safe operation of the power grid. In this contribution, the finite element simulation model of a 35 kV three-core optical fiber composite submarine cable with a suspended span length of 9.5 m is established. The natural frequency of the model is obtained through modal analysis. Then the vortex-induced vibration is simulated by the fluid–structure coupling method, and the stress distribution and change law of the torsional optical fiber is extracted. The results show that in the submarine cable, there appears to be a beating vibration and locking phenomena respectively, under two flow velocities. The transverse vibration amplitude of the latter increases significantly due to a resonance state. When the flow direction is perpendicular to the submarine cable, the stress distribution of the torsional optical fiber at the initial moment and at the 1/2 T moment of a vibration cycle approximately represents a mirror image relationship. In addition, the frequency of the stress change is the same as the frequency of the vortex-induced vibration, which can judge whether the vortex-induced vibration occurs. Moreover, the vortex-induced vibration range can be determined by the maximum stress change location.
In recent years, the water blocking tape in high-voltage (HV) crosslinked polyethylene (XLPE) cable is suffered from penetrating moisture frequently, which affects its safe and stable operation, while there are no effective detection methods yet. In this paper, a 110 kV cable sample was prepared, with a single-mode fiber of 30 m built in it. Meanwhile, a distributed detection system for built-in optical fiber of 110 kV cable was established and the criterion for BOTDR breakpoint detection method was proposed. The comparison test of breakpoint detection methods for built-in optical fiber was carried out using Brillouin optical time domain reflectometry (BOTDR) and optical time domain reflectometry (OTDR). Besides, detection tests of moisture water blocking tape including its drying process were launched using BOTDR. The relationship of Brillouin frequency shift (BFS) with moisture length, position, and drying process of the tape was studied. The results have demonstrated that BOTDR plays a better role in detecting breakpoint with poor-quality end face than OTDR. By using BOTDR to detect moisture tape in cable, the BFS decreases sharply when moisture length over some thresholds and linearly falls with increasing moisture length. As time passes, the BFS gradually increases, which can characterize drying process.
22 January 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Temperature sensitivity coefficient of optical fiber is a critical parameter for distributed temperature measurement based on Brillouin scattering. However, the optical fiber required by traditional coefficient measurement method, is so long that it is not suitable for embedded optical fiber in high-voltage (HV) cross-linked polyethylene (XLPE) power cables. In this paper, a measuring system for temperature sensitivity coefficient of distributed Brillouin scattering optical fiber is established. By modulating the temperature of a short section of optical fiber to be remarkably differ from that of remaining optical fiber within the spatial resolution of sensing system, the coefficient can be obtained through measuring the Brillouin frequency shift (BFS) of the modulated peak in Brillouin gain spectrum (BGS). The results show that using Brillouin optical time domain reflectometer (BOTDR) with a spatial resolution of 10 m, the coefficient obtained by optical fiber longer than 0.5 m is the same as that obtained by 10 m optical fiber. As the phenomenon that the temperature sensitivity coefficient of polyvinyl chloride (PVC) jacketed optical fiber in the water blocking tape and power cable are both 1.4 MHz/°C, the embedded optical fiber in tape can be used to replace that in HV XLPE cable to measure the coefficient.
19 January 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
In recent years, buffer layer defects have occur in high-voltage (HV) crosslinked polyethylene (XLPE) cable frequently, which affects its safe and stable operation, while there are no effective detection methods yet. In this paper, a 110 kV cable sample was prepared, embedded with single-mode optical fiber. Meanwhile, a distributed optical fiber detection system for buffer layer defects based on Brillouin optical time domain reflectometry (BOTDR) was built. The partial discharge (PD) test and BOTDR detection test for defective cable were conducted to study the relationship between Brillouin frequency shift (BFS) variation of built-in fiber and temperature rise resulting from dielectric loss, white powder, and damaged insulation. During applying voltage of 96 kV for 7 hours, the BFS variations within white powder and damaged insulation defects are significantly larger than that within non-defect which is only determined by dielectric loss. The BFS variations are closely related to the number and depth of damaged insulation holes, as well as circumferential angle of holes against optical fiber. But the BFS variations within moisture water blocking tape, poor electrical connection, and damaged insulation screen cannot be distinguished from that within non-defect.
Accurate and rapid calculation for cable’s conductor temperature, coupled with timely alerts, is crucial for the safe and stable operation of cables. In this paper, we present a study on a rapid calculation and graded early warning system for conductor temperatures of 10 kV cross-linked polyethylene (XLPE) cables, detailing the system architecture and graded warning strategy. Firstly, a coupled electric-thermal-fluid finite element model is established, which is used to determine the warning temperatures for the cable outer sheath. Secondly, a rapid calculation method for the conductor transient temperature is proposed, which is based on the superposition principle. Finally, the accuracy and practicality of this system are verified by actual monitoring data and finite element simulation. The results demonstrate that the system can accurately calculate transient conductor temperatures with error less than 1 °C and computation time less than 1 second, indicating significantly applicable value in engineering. Based on the system, accurate conductor temperature calculations and alerts can be made, providing a theoretical basis for operation and maintenance of urban distribution cable lines.