Helge Pfeiffer

Dr. Helge Pfeiffer

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2009 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
JPJeroen Pollet
Jeroen Pollet
FDFilip Delport
Filip Delport
KJKris Pieter Frans Janssen
Kris Pieter Frans Janssen
KJKarolien Jans
Karolien Jans
GMGuido Maes
Guido Maes
JLJeroen Lammertyn
Jeroen Lammertyn

8 February 2016 in Medical Physics
Verified
Journal Article
Closed access
PDF file
MCM. Callens
M. Callens
WCW. Crijns
W. Crijns
VSV. Simons
V. Simons
IWI. De Wolf
I. De Wolf
TDT. Depuydt
T. Depuydt
KAKoen Van Den Abeele
Koen Van Den Abeele

1 July 2015 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
BGB. Gielen
B. Gielen
JJJ. Jordens
J. Jordens
JJJ. Janssen
J. Janssen
HPHelge Pfeiffer
Helge Pfeiffer
MWMartine Wevers
Martine Wevers
TGTom Van Gerven
Tom Van Gerven
The bubble type, generated by an ultrasonic field, was studied in a batch and flow reactor using a multibubble sonoluminescence (MBSL) quenching technique with propanol and acetone. The influence of frequency and transducer configuration was evaluated using the same piezoelectric element in both setups. Results show that the bubble type not only depends on the frequency, but also on the input power or transducer configuration. Additionally, the effect of flow on sonoluminescence yield and bubble type was studied in the continuous setup at various frequencies. As the flow becomes turbulent, the sonoluminescence signal reaches a plateau for three out of four frequencies, and a transition from transient to stable cavitation occurs for frequencies below 200 kHz.

1 January 2015 in Advances in Condensed Matter Physics
Verified
Journal Article
Open access
PDF file
PLPatricia Losada-Pérez
Patricia Losada-Pérez
NMN. Mertens
N. Mertens
BMB. de Medio-Vasconcelos
B. de Medio-Vasconcelos
ESE. Slenders
E. Slenders
JLJ. Leys
J. Leys
JTJ. Thoen
J. Thoen
The phase transitions of binary lipid mixtures are studied by a combination of Peltier-element-based adiabatic scanning calorimetry (pASC) and quartz crystal microbalance with dissipation monitoring (QCM-D). pASC, a novel type of calorimeter, provides valuable and unambiguous information on the heat capacity and the enthalpy, whereas QCM-D is proposed as a genuine way of determining phase diagrams by analysing the temperature dependence of the viscosity. Two binary mixtures of phospholipids with the same polar head and differing in the alkyl chain length, DMPC + DPPC and DMPC + DSPC, are discussed. Both techniques give consistent phase diagrams, which compare well with literature results, showing their capability to map the phase behaviour of pure lipids as well as lipid mixtures. This work can be considered as a departure point for further investigations on more complex lipid mixtures displaying relevant phases such as the liquid-ordered phase and solid-lipid interfaces with biologically functional importance.

30 March 2017 in Medical Physics
Verified
Journal Article
Open access
PDF file
MCMaarten B. Callens
Maarten B. Callens
WCWouter Crijns
Wouter Crijns
TDTom Depuydt
Tom Depuydt
KHKarin Haustermans
Karin Haustermans
FMFrederik Maes
Frederik Maes
KAKoen Van Den Abeele
Koen Van Den Abeele
Purpose The aim of this work was to model the dose dependence of the darkening of GafChromic™ EBT3 films by combining the optical properties of the polydiacetylene polymer phases, and a modified version of the single‐hit model, which will take the stick‐like shape of the monomer microcrystals into account. Second, a comparison is made between the quantification of the film darkening by flatbed scanning and by UV‐vis absorption spectroscopy. Method GafChromicTMEBT3 films were irradiated with a 6 MV photon beam at dose levels between 0 and 50 Gy. The radiation‐induced darkening of the films is quantified by a flatbed scanner, and by UV‐vis absorption spectroscopy in the wavelength range of 220–750 nm. From the UV‐vis absorption spectra, the contribution of each polymer phase to the absorbance was deduced. Next, the dose dependence of the polymer content is described by a modified single‐hit model where the size distribution of polymerizable centers is approximated by way of the size distribution of the monomer microcrystals in the film. Results The absorption properties of the film can be accurately quantified by UV‐vis spectroscopy for dose levels between 0 and 10 Gy. Over 10 Gy, the absorption spectrum saturates due to the limited sensitivity of the spectrometer. The modified single‐hit model was successful in describing the increasing polymer concentration with radiation dose, using a log‐normal distribution for the length of the stick‐like monomer microcrystals. The dose dependence of the polymer content, deduced from the UV‐vis absorption spectrum, differs from that of the flatbed scanning method and is more sensitive to changes in dose. Conclusion The dose dependence of the polymer concentration can be modeled by taking into account the distribution of active centers using the microstructure of the active layer for dose levels between 0 and 10 Gy. The dissimilar dose dependence of the polymer concentration and the absorbance must be accounted for when modeling darkening from the kinetics of the photopolymerization reaction.

11 April 2005 in Chemphyschem
Verified
Journal Article
Closed access
PDF file
HPHelge Pfeiffer
Helge Pfeiffer
KHKarel Heremans
Karel Heremans