Lohitha Kalluri

Ms. Lohitha Kalluri

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2022 in Ceramics
Verified
Journal Article
Open access
PDF file
LALaura Helena Jung Alberto
Laura Helena Jung Alberto
LKLohitha Kalluri
Lohitha Kalluri
Josephine Esquivel-UpshawJosephine Esquivel-Upshaw
Josephine Esquivel-Upshaw
YDYuanyuan Duan
Yuanyuan Duan
All-ceramic fixed dental prostheses (FDPs) tend to fracture at the connector regions due to high stress concentration at these areas influenced by their design. This study was performed as an adjunct to an existing clinical study to evaluate the influence of the different radii of curvature of gingival embrasure on the stress distribution of a three-unit all-ceramic implanted supported FDP. Three three-dimensional (3D) models were created by scanning two titanium dental implants, their suitable zirconia abutments, and a patient-retrieved dental prosthesis using a micro-CT scanner. The radius of curvature of the gingival embrasure for the distal connector of the FDP was altered to measure 0.25 mm, 0.50 mm, and 0.75 mm. A finite element analysis (FEA) software (ABAQUS) was used to evaluate the impact of different connector designs on the distribution of stresses. Maximum Principal Stress data was collected from the individual components (veneer, framework, and abutments). The radius of curvature of gingival embrasure had a significant influence on the stress distribution at the assessed components. The tensile peak stresses at all structures were highest in the 0.25 mm model, while the 0.50 mm and 0.75 mm models presented similar values and more uniform stress distribution.

6 March 2023 in Materials
Verified
Journal Article
Open access
PDF file
LALaura Helena Jung Alberto
Laura Helena Jung Alberto
LKLohitha Kalluri
Lohitha Kalluri
JQJing Qu
Jing Qu
YZYongfeng Zhao
Yongfeng Zhao
YDYuanyuan Duan
Yuanyuan Duan
Polycaprolactone (PCL) micro- and nanoparticles produced using the electrospraying technique present high drug encapsulation capacity, a controllable surface area, and a good cost–benefit ratio. PCL is also considered a non-toxic polymeric material with excellent biocompatibility and biodegradability. All these characteristics make PCL micro- and nanoparticles a promising material for tissue engineering regeneration, drug delivery, and surface modification in dentistry. In this study, PCL electrosprayed specimens were produced and analyzed to determine their morphology and size. Three PCL concentrations (2, 4, and 6 wt%) and three solvent types (chloroform (CF), dimethylformamide (DMF), and acetic acid (AA)) with various solvent mixtures ratios (1:1 CF/DMF, 3:1 CF/DMF, 100% CF, 1:1 AA/CF, 3:1 AA/CF, and 100% AA) were used while keeping the remaining electrospray parameters constant. SEM images followed by ImageJ analysis showed a change in the morphology and size of the particles among various tested groups. A two-way ANOVA demonstrated a statistically significant interaction (p < 0.001) between PCL concentration and solvents on the size of the particles. With the increase in the PCL concentration, an increase in the number of fibers was observed among all the groups. The morphology and dimensions of the electrosprayed particles, as well as the presence of fibers, were significantly dependent on the PCL concentration, choice of solvent, and solvent ratio.

Verified
Journal Article
Open access
PDF file
LKLohitha Kalluri
Lohitha Kalluri
YDYuanyuan Duan
Yuanyuan Duan
Our objective was to determine and optimize the significant parameters affecting mechanical properties and mean fiber diameter (MFD) of a novel GTR/GBR membrane composed of polycaprolactone (PCL) and chicken eggshell membrane (ESM). For this, we prepared electrospun membrane specimens (n = 16) with varying concentrations of PCL, ESM, nano-hydroxyapatite (HAp), and altered electrospinning parameters as generated by DOE++ software. After the determination of MFD and mechanical properties for all specimens, Taguchi orthogonal array L8 design was used to screen significant factors affecting the MFD and mechanical properties. PCL wt%, ESM wt%, HAp wt%, applied voltage (AV), flow rate (FR), and spinneret-collector distance (SCD) were the independent variables investigated. The response variables analyzed were MFD, tensile strength (TS), and elastic modulus. ANOVA outlined ESM wt%, HAp wt%, AV, FR, SCD, and an interactive effect between PCL wt% and AV to be the significant factors affecting modulus values of an electrospun PCL/ESM membrane (p < 0.05). Furthermore, concentrations of PCL and ESM were the significant factors affecting MFD (p < 0.05) and there were no significant factors affecting the TS values. Optimization using DOE++ software predicted that the maximal TS of 3.125 MPa, modulus of 278.168 MPa, and MFD of 882.75 nm could be achieved.

24 February 2024 in Dental Materials
Verified
Journal Article
Closed access
LKLohitha Kalluri
Lohitha Kalluri
JGJason A. Griggs
Jason A. Griggs
AJAmol V. Janorkar
Amol V. Janorkar
XXXiaoming Xu
Xiaoming Xu
RCRavi Chandran
Ravi Chandran
YDYuanyuan Duan
Yuanyuan Duan

28 April 2021 in Ceramics
Verified
Journal Article
Open access
PDF file
LKLohitha Kalluri
Lohitha Kalluri
BSBernard Seale
Bernard Seale
MSMegha Satpathy
Megha Satpathy
Josephine Esquivel-UpshawJosephine Esquivel-Upshaw
Josephine Esquivel-Upshaw
YDYuanyuan Duan
Yuanyuan Duan
This study was performed as an adjunct to an existing clinical study to validate the effect of veneer: framework thickness ratio on stress distribution in an implant-supported all-ceramic fixed partial denture. Two commercially available titanium dental implants with corresponding customized abutments and a patient-retrieved all-ceramic fixed partial denture were scanned using a high-resolution micro-CT scanner. Reconstructed 3D objects, along with a simulated bone surface, were incorporated into a non-manifold assembly and meshed simultaneously using Simpleware software (Synopsys Simpleware ScanIP Version P-2019.09; Mountain View, CA). Three such volume meshes (Model A, Model B, Model C) corresponding to veneer: framework thickness ratios of 3:1, 1:1, and 1:3 respectively were created, and exported to a finite element analysis software (ABAQUS). An axial load of 110 N was applied uniformly on the occlusal surfaces to calculate the static stresses and contour plots were generated in the post-processing module. From the data obtained, we observed optimum stress distribution in Model B. Also, the tensile stresses were concentrated in the posterior connector region of the prosthesis in all three models tested. Within the limitations of this study, we can conclude that equal thickness of veneer and framework layers would aid in better stress distribution.

7 November 2022 in Symmetry
Verified
Journal Article
Open access
PDF file
LALaura Helena Jung Alberto
Laura Helena Jung Alberto
LKLohitha Kalluri
Lohitha Kalluri
Josephine Esquivel-UpshawJosephine Esquivel-Upshaw
Josephine Esquivel-Upshaw
YDYuanyuan Duan
Yuanyuan Duan
All-ceramic fixed dental prostheses (FDPs) tend to fracture in the connector areas, due to the concentration of tensile stresses. This study aimed to evaluate the role of connector height on the stress distribution of a posterior three-unit implant-supported all-ceramic FDP using finite element analysis (FEA). Two titanium dental implants, their abutments, screws, and a three-unit all-ceramic FDP were scanned using a micro-CT scanner. Three 3D models with altered distal connector heights (3, 4, and 5 mm) were generated and analyzed on ABAQUS FEA software. The maximum principal stress values in MPa observed for each model with different connector heights and their respective locations (MA = mesial abutment; DA = distal abutment; F = framework; V = veneer) were: 3 mm—219 (MA), 88 (DA), 11 (F), 16 (V); 4 mm—194 (MA), 82 (DA), 8 (F), 18 (V); 5 mm—194 (MA), 80 (DA), 8 (F), and 18 (V). All the assembled models demonstrated the peak stresses at the neck area on the mesial abutments. The connector height had a significant influence on the stress distribution of the prosthesis. The models with higher distal connectors (4 and 5 mm) had a lower and more uniform distribution of maximum principal stresses (except for the veneer layer) when compared with the model with the smallest distal connector.