Yeonsun Choi

Ms. Yeonsun Choi

Sungkyunkwan University (SKKU)
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2021 in Polymers
Verified
Journal Article
Open access
PDF file
YCYeonsun Choi
Yeonsun Choi
KPKyuha Park
Kyuha Park
HCHeewon Choi
Heewon Choi
Donghee SonDonghee Son
Donghee Son
Mikyung ShinMikyung Shin
Mikyung Shin
Implantable electronics have recently been attracting attention because of the promising advances in personalized healthcare. They can be used to diagnose and treat chronic diseases by monitoring and applying bioelectrical signals to various organs. However, there are challenges regarding the rigidity and hardness of typical electronic devices that can trigger inflammatory reactions in tissues. In an effort to improve the physicochemical properties of conventional implantable electronics, soft hydrogel-based platforms have emerged as components of implantable electronics. It is important that they meet functional criteria, such as stretchability, biocompatibility, and self-healing. Herein, plant-inspired conductive alginate hydrogels composed of “boronic acid modified alginate” and “oligomerized epigallocatechin gallate,” which are extracted from plant compounds, are proposed. The conductive hydrogels show great stretchability up to 500% and self-healing properties because of the boronic acid-cis-diol dynamic covalent bonds. In addition, as a simple strategy to increase the electrical conductivity of the hydrogels, ionically crosslinked shells with cations (e.g., sodium) were generated on the hydrogel under physiological salt conditions. This decreased the resistance of the conductive hydrogel down to 900 ohm without trading off the original properties of stretchability and self-healing. The hydrogels were used for “electrophysiological bridging” to transfer electromyographic signals in an ex vivo muscle defect model, showing a great bridging effect comparable to that of a muscle-to-muscle contact model. The use of plant-inspired ionically conductive hydrogels is a promising strategy for designing implantable and self-healable bioelectronics.

9 August 2022 in Polymers
Verified
Journal Article
Open access
PDF file
JJJaewon Ju
Jaewon Ju
JKJungwoo Kim
Jungwoo Kim
YCYeonsun Choi
Yeonsun Choi
SJSubin Jin
Subin Jin
SKSumin Kim
Sumin Kim
Mikyung ShinMikyung Shin
Mikyung Shin
For recently devised wound-healing materials, a variety of acute application systems with sustainable therapeutic effects on wound sites have been suggested. For example, hydrogel-type healing agents with porous structures and high drug encapsulation efficiencies have been developed for wound repair. However, challenges remain about the poor mechanical and adhesive properties of hydrogels. Herein, we propose a punicalagin (PC)-containing wound-healing hydrogel in adhesive form that is mechanically stable and has sustainable wound-healing therapeutic efficiency. The APC hydrogel, composed of alginate (ALG), PC, and chitosan–gallol (CHI–G), exhibits significant mechanical and self-healing properties, thus indicating that PC increases cross-linking in ALG/CHI–G as macromolecule. The PC-containing mechanically enhanced hydrogel demonstrates high tissue adhesiveness. Sustainable PC release for 192 h, which indicates high therapeutic effect of the released PC, and great blood compatibility are evaluated based on rapid blood coagulation and minimal hemolysis. The cytocompatibility and wound-healing abilities of the PC-containing APC hydrogel are greater than those of the non-PC hydrogel, as verified by cell compatibility and wound scratch assays. These results indicate that a suitable concentration of PC-containing hydrogel with sustainable moisture condition and PC release may inspire further polyphenol-agent-containing hydrogels as wound-healing agents with structural stability and therapeutic efficiency.

1 January 2009 in Journal of Nanoscience and Nanotechnology
Verified
Journal Article
Closed access
IKInpil Kang
Inpil Kang
MSMark J Schulz
Mark J Schulz
YCYeonsun Choi
Yeonsun Choi
SHSung-Ho Hwang
Sung-Ho Hwang
CNT composites demonstrate sensory materials properties such as piezoresistivity, chemical and bio selectivity and they can detect structural deterioration, chemical contamination and bio signal by means of their impedance measurement (resistance and capacitance). In this study, electrical impedance characteristics of CNT composite electrodes are studied to simultaneously detect mechanical and chemical symptoms in engineering applications. We measured variations of electrical resistance and capacitance values of CNT composite electrodes under static load for mechanical sensing behavior and under the change of buffer solution amount for chemical sensing behavior. At the mechanical sensing behavior test, the resistance values changed quite linearly under bending and compression loads while the capacitance value varied within small range with invalid relationship to the loads. At the chemical sensing behavior investigation, the electrode's capacitance showed drastic change while the resistance value only changed within few percent range. The independently changing pattern of electrical impedance parameters according to mechanical strain and chemical effect can provide new opportunities to design a novel multifunctional sensor that can simultaneously monitor mechanical and chemical behaviors of a target system.

9 September 2001
Verified
Conference Paper
Closed access
PDF file
YCYeonsun Choi
Yeonsun Choi
CBChul-Yong Bae
Chul-Yong Bae
Partial rotor rub occurs when an obstacle on the Stator of a rotating machinery disturbs the free whirling motion of a rotor, which is more common than full annular rub for the cases of rubbing in rotating machinery. The nonlinearity due to the intermittent contacts and friction during partial rotor rub makes the phenomenon complex. The several nonlinear phenomena of superharmonics, subharmonics, and jump phenomenon are demonstrated for the partial rub using an experimental apparatus in this study. The forward or backward components in its orbit patterns are calculated using the directional spectrum for the experimental results and are demonstrated by numerical simulations. A piecewise-linear model and a rebound model using the coefficient of restitution are investigated on the basis of experimental observations in order to adopt an analytical model of the contact between the rotor and stator during whirling motion. The contact stiffness, coefficient of restitution, and friction coefficient for the contact during partial rub are calculated from the comparison between the numerical simulation and the experimental results. Also, the numerical simulations for the model of partial rub are done for the various system parameters of clearance, contact stiffness, and friction coefficient in order to find the nonlinear behavior of partial rotor rub.

1 July 2005 in Transactions of the Korean Society for Noise and Vibration Engineering
Verified
Journal Article
Open access
SPSangmoon Park
Sangmoon Park
YCYeonsun Choi
Yeonsun Choi