Detecting gait phases with wearables unobtrusively and reliably in real-time is important for clinical gait rehabilitation and early diagnosis of neurological diseases. Due to hardware limitations of microcontrollers in wearable devices (e.g., memory and computation power), reliable real-time gait phase detection on the microcontrollers remains a challenge, especially for long-term real-world free-living gait. In this work, a novel algorithm based on a reduced support vector machine (RSVM) and a finite state machine (FSM) is developed to address this. The RSVM is developed by exploiting the cascaded K-means clustering to reduce the model size and computation time of a standard SVM by 88% and a factor of 36, with only minor degradation in gait phase prediction accuracy of around 4%. For each gait phase prediction from the RSVM, the FSM is designed to validate the prediction and correct misclassifications. The developed algorithm is implemented on a microcontroller of a wearable device and its real-time (on the fly) classification performance is evaluated by twenty healthy subjects walking along a predefined real-world route with uncontrolled free-living gait. It shows a promising real-time performance with an accuracy of 91.51%, a sensitivity of 91.70%, and a specificity of 95.77%. The algorithm also demonstrates its robustness with varying walking conditions.
The deterioration of gait can be used as a biomarker for ageing and neurological diseases. Continuous gait monitoring and analysis are essential for early deficit detection and personalized rehabilitation. The use of mobile and wearable inertial sensor systems for gait monitoring and analysis have been well explored with promising results in the literature. However, most of these studies focus on technologies for the assessment of gait characteristics, few of them have considered the data acquisition bandwidth of the sensing system. Inadequate sampling frequency will sacrifice signal fidelity, thus leading to an inaccurate estimation especially for spatial gait parameters. In this work, we developed an inertial sensor based in-shoe gait analysis system for real-time gait monitoring and investigated the optimal sampling frequency to capture all the information on walking patterns. An exploratory validation study was performed using an optical motion capture system on four healthy adult subjects, where each person underwent five walking sessions, giving a total of 20 sessions. Percentage mean absolute errors (MAE%) obtained in stride time, stride length, stride velocity, and cadence while walking were 1.19%, 1.68%, 2.08%, and 1.23%, respectively. In addition, an eigenanalysis based graphical descriptor from raw gait cycle signals was proposed as a new gait metric that can be quantified by principal component analysis to differentiate gait patterns, which has great potential to be used as a powerful analytical tool for gait disorder diagnostics.
Chemically driven micromotors display unpredictable trajectories due to the rotational Brownian motion interacting with the surrounding fluid molecules. This hampers the practical applications of these tiny robots, particularly where precise control is a requisite. To overcome the rotational Brownian motion and increase motion directionality, robots are often decorated with a magnetic composition and guided by an external magnetic field. However, despite the straightforward method, explicit analysis and modeling of their motion have been limited. Here, catalytic Janus micromotors are fabricated with distinct magnetizations and a controlled self‐propelled motion with magnetic steering is shown. To analyze their dynamic behavior, a dynamic model that can successfully predict the trajectory of micromotors in uniform viscous flows in real time by incorporating a form of state‐dependent‐coefficient with a robust two‐stage Kalman filter is theoretically developed. A good agreement is observed between the theoretically predicted dynamics and experimental observations over a wide range of model parameter variations. The developed model can be universally adopted to various designs of catalytic micro‐/nanomotors with different sizes, geometries, and materials, even in diverse fuel solutions. Finally, the proposed model can be used as a platform for biosensing, detecting fuel concentration, or determining small‐scale motors’ propulsion mechanisms in an unknown environment.
Motion capture systems are widely accepted as ground-truth for gait analysis and are used for the validation of other gait analysis systems. To date, their reliability and limitations in manual labeling of gait events have not been studied.Objectives: Evaluate manual labeling uncertainty and introduce a hybrid stride detection and gait-event estimation model for autonomous, long-term, and remote monitoring.Methods: Estimate inter-labeler inconsistencies by computing the limits-of-agreement. Develop a hybrid model based on dynamic time warping and convolutional neural network to identify valid strides and eliminate non-stride data in inertial (walking) data collected by a wearable device. Finally, detect gait events within a valid stride region.Results: The limits of inter-labeler agreement for key gait events heel off, toe off, heel strike, and flat foot are 72, 16, 24, and 80 ms, respectively; The hybrid model's classification accuracy for stride and non-stride are 95.16 and 84.48%, respectively; The mean absolute error for detected heel off, toe off, heel strike, and flat foot are 24, 5, 9, and 13 ms, respectively, when compared to the average human labels.Conclusions: The results show the inherent labeling uncertainty and the limits of human gait labeling of motion capture data; The proposed hybrid-model's performance is comparable to that of human labelers, and it is a valid model to reliably detect strides and estimate the gait events in human gait data.Significance: This work establishes the foundation for fully automated human gait analysis systems with performances comparable to human-labelers.
Measuring balance is important for detecting impairments and developing interventions to prevent falls, but there is no consensus on which method is most effective. Many balance metrics derived from steady-state walking data have been proposed, such as step-width variability, step-time variability, foot placement predictability, maximum Lyapunov exponent and margin of stability. Recently, perturbation-based metrics such as center of mass displacement have also been explored. Perturbations typically involve unexpected disturbances applied to the subject. In this study we collected walking data from 10 healthy human subjects while walking normally and while impairing balance with ankle braces, eye-blocking masks and pneumatic jets on their legs. In some walking trials we also applied mechanical perturbations to the pelvis. We obtained a comprehensive biomechanics dataset and compared the ability of various metrics to detect impaired balance using steady-state walking and perturbation recovery data. We also compared metric performance using thresholds informed by data from multiple subjects versus subject-specific thresholds. We found that step-width variability, step-time variability and foot placement predictability, using steady-state data and subject-specific thresholds, detected impaired balance with the highest accuracy (≥86%), whereas other metrics were less effective (≤68%). Incorporating perturbation data did not improve accuracy of these metrics, although this comparison was limited by the small amount of perturbation data included and analyzed. Subject-specific baseline measurements improved the detection of changes in balance ability. Thus, in clinical practice, taking baseline measurements might improve the detection of impairment due to aging or disease progression.