Shahin Tabandeh

Dr. Shahin Tabandeh

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Giovanni GugliandoloGiovanni Gugliandolo
Giovanni Gugliandolo
STShahin Tabandeh
Shahin Tabandeh
LRLucia Rosso
Lucia Rosso
DSDenis Smorgon
Denis Smorgon
VFVito Fernicola
Vito Fernicola
In this work, the authors exploited the whispering gallery mode (WGM) resonator properties as a thermometer. The sensor is made of a cylindrical sapphire microwave resonator in the center of a gold-plated copper cavity. Two coaxial cables act as antennas and excite the WGM standing waves in the cylindrical sapphire at selected resonance frequencies in the microwave range. The system affords a high quality factor that enables temperature measurements with a resolution better than 15 µK and a measurement standard uncertainty of 1.2 mK, a value approximately three times better than that achieved in previous works. The developed sensor could be a promising alternative to platinum resistance thermometers, both as a transfer standard in industrial applications and as an interpolating instrument for the dissemination of the kelvin.

9 January 2025 in Metrology
Verified
Journal Article
Open access
PDF file
PHPeter Harris
Peter Harris
PØPeter Friis Østergaard
Peter Friis Østergaard
STShahin Tabandeh
Shahin Tabandeh
HSHenrik Söderblom
Henrik Söderblom
GKGertjan Kok
Gertjan Kok
MIMaitane Iturrate-Garcia
Maitane Iturrate-Garcia
Sensor networks, which are increasingly being used in a broad range of applications, constitute a measurement paradigm involving ensembles of sensors measuring possibly different quantities at a discrete sample of spatial locations and temporal points outside the laboratory. If sensor networks are to be considered as true metrology systems and the measurement results derived from them used for decision-making, such as in a regulatory context, it is important that the results are accompanied by reliable statements of measurement uncertainty. This paper gives a preview of some of the work undertaken within the European-funded ‘Fundamental principles of sensor network metrology (FunSNM)’ project to address the challenges of measurement uncertainty evaluation in some real-world sensor network applications. The applications demonstrate that sensor networks possess features related to the nature of the measured quantities, to the nature of the measurement model, and to the nature of the measured data. These features make conventional methods of measurement uncertainty evaluation, and established guidelines for measurement uncertainty evaluation difficult to apply. An overview of some of the modelling tools used to address the challenges of measurement uncertainty evaluation in those applications is given.

29 April 2022 in Optics
Verified
Journal Article
Open access
PDF file
TBTristan Briant
Tristan Briant
SKStephan Krenek
Stephan Krenek
ACAndrea Cupertino
Andrea Cupertino
FLFerhat Loubar
Ferhat Loubar
RBRémy Braive
Rémy Braive
SBStéphan Briaudeau
Stéphan Briaudeau
Temperature is one of the most relevant physical quantities that affects almost all processes in nature. However, the realization of accurate temperature standards using current temperature references, like the triple point of water, is difficult due to the requirements on material purity and stability of the environment. In addition, in harsh environments, current temperature sensors with electrical readout, like platinum resistors, are difficult to implement, urging the development of optical temperature sensors. In 2018, the European consortium Photoquant, consisting of metrological institutes and academic partners, started investigating new temperature standards for self-calibrated, embedded optomechanical sensor applications, as well as optimised high resolution and high reliability photonic sensors, to measure temperature at the nano and meso-scales and as a possible replacement for the standard platinum resistant thermometers. This article presents an overview of the results obtained with sensor prototypes that exploit photonic and optomechanical techniques for sensing temperatures over a large temperature range (5 K to 300 K). Different concepts are demonstrated, including ring resonators, ladder-like resonators and suspended membrane optomechanical thermometers, highlighting initial performance and challenges, like self-heating that need to be overcome to realize photonic and optomechanical thermometry applications.

1 January 2024 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
AKAlexander Kirste
Alexander Kirste
JEJost Engert
Jost Engert
JPJukka P. Pekola
Jukka P. Pekola
JPJoonas Peltonen
Joonas Peltonen
STShahin Tabandeh
Shahin Tabandeh
FSFernando Sparasci
Fernando Sparasci
With the redefinition of the kelvin in 2019 and the new mise en pratique for the definition of the kelvin (MeP-K) [1], the realization of the kelvin is no longe With the redefinition of the kelvin in 2019 and the new mise en pratique for the definition of the kelvin (MeP-K) [1], the realization of the kelvin is no longe

7 March 2026 in Measurement: Digitalization
Verified
Journal Article
Open access
HSHenrik Söderblom
Henrik Söderblom
MZMartha Arbayani Zaidan
Martha Arbayani Zaidan
MIMaitane Iturrate-Garcia
Maitane Iturrate-Garcia
HSHasan Sarwar
Hasan Sarwar
RHRichard Högström
Richard Högström
STShahin Tabandeh
Shahin Tabandeh

3 July 2026 in Sensors
Verified
Journal Article
Open access
PDF file
VFVito Fernicola
Vito Fernicola
GBGiulio Beltramino
Giulio Beltramino
ACAntonio Castrillo
Antonio Castrillo
RCR. Cuccaro
R. Cuccaro
RDRegina Deschermeier
Regina Deschermeier
STShahin Tabandeh
Shahin Tabandeh
Trace water is one of the most critical matrix contaminants in ultra-high-purity (UHP) process gases, like argon (Ar), nitrogen (N2), and many others. Even trace amounts can severely degrade the quality of many products that are reliant on these gases. Despite its importance to advanced technology sectors, notably semiconductor manufacturing, it has proven quite difficult to realize preparative or analytical trace water metrology over the full amount fraction range needed or in the broad spectrum of industrially relevant matrix gases. Within the EU-funded PROMETH2O project consortium, this challenge has been addressed through the development or significant improvement of traceable measurement methods and standards spanning 5 nmol⋅mol−1 to 5 µmol⋅mol−1, tailored for use in UHP process gas production, such as Ar, N2 and clean dry air (CDA). The measurement ranges were extended and the uncertainties were improved while being consistent with the current best practice at primary humidity standard laboratories. The developed standards provide combined standard uncertainties ranging from approximately 0.4 % to 1.5 % in water vapor amount fraction and from 0.03 °C to 0.07 °C in frost-point temperature, while the comb-assisted CRDS system achieves detection limits in the sub-ppb to ppt range. These capabilities were validated in applications that are relevant to process instrumentation and the gas industry. A distributed metrological infrastructure at various European national metrology institutes and partner sites now provides SI-traceable trace water measurements in UHP gases, strongly supporting and extending the calibration capabilities for the gas and semiconductor industries and the associated stakeholders.