Peter Friis Østergaard

Dr. Peter Friis Østergaard

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2025 in Metrology
Verified
Journal Article
Open access
PDF file
PHPeter Harris
Peter Harris
PØPeter Friis Østergaard
Peter Friis Østergaard
STShahin Tabandeh
Shahin Tabandeh
HSHenrik Söderblom
Henrik Söderblom
GKGertjan Kok
Gertjan Kok
MIMaitane Iturrate-Garcia
Maitane Iturrate-Garcia
Sensor networks, which are increasingly being used in a broad range of applications, constitute a measurement paradigm involving ensembles of sensors measuring possibly different quantities at a discrete sample of spatial locations and temporal points outside the laboratory. If sensor networks are to be considered as true metrology systems and the measurement results derived from them used for decision-making, such as in a regulatory context, it is important that the results are accompanied by reliable statements of measurement uncertainty. This paper gives a preview of some of the work undertaken within the European-funded ‘Fundamental principles of sensor network metrology (FunSNM)’ project to address the challenges of measurement uncertainty evaluation in some real-world sensor network applications. The applications demonstrate that sensor networks possess features related to the nature of the measured quantities, to the nature of the measurement model, and to the nature of the measured data. These features make conventional methods of measurement uncertainty evaluation, and established guidelines for measurement uncertainty evaluation difficult to apply. An overview of some of the modelling tools used to address the challenges of measurement uncertainty evaluation in those applications is given.

25 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
QBQuentin Baire
Quentin Baire
MDMiruna Dobre
Miruna Dobre
APAnne-Sophie Piette
Anne-Sophie Piette
Luca Giovanni LanzaLuca Giovanni Lanza
Luca Giovanni Lanza
Arianna CauteruccioArianna Cauteruccio
Arianna Cauteruccio
CICarmen Garcia Izquierdo
Carmen Garcia Izquierdo
Precipitation is among the most important meteorological variables for, e.g., meteorological, hydrological, water management and climate studies. In recent years, non-catching precipitation gauges are increasingly adopted in meteorological networks. Despite such growing diffusion, calibration procedures and associated uncertainty budget are not yet standardized or prescribed in best practice documents and standards. This paper reports a metrological study aimed at proposing calibration procedures and completing the uncertainty budgets, to make non-catching precipitation gauge measurements traceable to primary standards. The study is based on the preliminary characterization of different rain drop generators, specifically developed for the investigation. Characterization of different models of non-catching rain gauges is also included.

28 January 2024 in Energies
Verified
Journal Article
Open access
PDF file
HKHenrik Kjeldsen
Henrik Kjeldsen
PØPeter Friis Østergaard
Peter Friis Østergaard
HSHelena Strauss
Helena Strauss
JNJan Nielsen
Jan Nielsen
BTBayan TALLAWI
Bayan TALLAWI
JHJens Ole Hougaard
Jens Ole Hougaard
This paper presents methodologies and equipment for SI-traceable inline measurements of water content (a critical quality parameter) in solid biofuels. Inline measurement systems for water content are commonly used at CHP plants, providing continuous real-time data. However, the accuracy of these systems is in most cases unsatisfactory, mainly because the systems are not calibrated representatively for the relevant material, and until now, calibrations traceable to the SI system have not been available. To provide reliable and accurate inline water content data, new procedures and equipment for calibrating measurement systems were developed. Two reference methods for the determination of water content were developed; one measures the airflow and dewpoint of desorbed water in the air passing a test sample, while the other uses a P2O₅-sensor. Additionally, a transfer standard based on a cavity resonance sensor was developed for fast onsite calibration of the inline sensor at the power plant. This new instrument allows for quick and accurate measurements. The transfer standard is made metrologically traceable to the primary measurement standards. The entire system was demonstrated by calibrating an inline microwave-based (MW) sensor at the CHP plant of VERDO in Randers, Denmark. Thus, a complete metrological traceability chain was established from an industrial to a primary standard.

7 April 2025 in EPJ Web of Conferences
Verified
Journal Article
Open access
PDF file
PØPeter Friis Østergaard
Peter Friis Østergaard
TDThomas S. Daugbjerg
Thomas S. Daugbjerg
GKGertjan Kok
Gertjan Kok
Unscented Kalman Filtering is applied to district heating meter data and GIS-data from a utility network to simultaneously identify temperature offsets in utility meters and service pipe insulation. Implementing estimation of the temperature in the main pipe allows for more accurate results, which also respect physical constraints. Unscented Transformations allow for easier implementation of the algorithm compared to existing solutions, as linearization is avoided. Correcting for potential offsets in the temperature measurement of the utility meter allows for a better estimation of the insulation level of the service pipe, improving the ability for the utilities to pinpoint their efforts in optimizing their renovation activities over several areas of interest.