Yanlu Li

Prof. Yanlu Li

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Yanlu LiYanlu Li
Yanlu Li
Emiel DieussaertEmiel Dieussaert
Emiel Dieussaert
Roel BaetsRoel Baets
Roel Baets
Laser Doppler vibrometry (LDV) is a non-contact vibration measurement technique based on the Doppler effect of the reflected laser beam. Thanks to its feature of high resolution and flexibility, LDV has been used in many different fields today. The miniaturization of the LDV systems is one important development direction for the current LDV systems that can enable many new applications. In this paper, we will review the state-of-the-art method on LDV miniaturization. Systems based on three miniaturization techniques will be discussed: photonic integrated circuit (PIC), self-mixing, and micro-electrochemical systems (MEMS). We will explain the basics of these techniques and summarize the reported miniaturized LDV systems. The advantages and disadvantages of these techniques will also be compared and discussed.

2 February 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
Yanlu LiYanlu Li
Yanlu Li
JZJinghao Zhu
Jinghao Zhu
MDMatthieu Duperron
Matthieu Duperron
POPeter O’brien
Peter O’brien
RSRalf Schüler
Ralf Schüler
RBRoel Baets
Roel Baets
This paper describes an integrated six-beam homodyne laser Doppler vibrometry (LDV) system based on a silicon-on-insulator (SOI) full platform technology, with on-chip photo-diodes and phase modulators. Electronics and optics are also implemented around the integrated photonic circuit (PIC) to enable a simultaneous six-beam measurement. Measurement of a propagating guided elastic wave in an aluminum plate (speed ≈ 909 m/s @ 61.5 kHz) is demonstrated.

1 September 2024 in Hypertension
Verified
Journal Article
Open access
SBSmriti Badhwar
Smriti Badhwar
LMLouise Marais
Louise Marais
HKHakim Khettab
Hakim Khettab
FPFederica Poli
Federica Poli
Yanlu LiYanlu Li
Yanlu Li
PBPierre Boutouyrie
Pierre Boutouyrie
BACKGROUND: Carotid-femoral pulse wave velocity (cfPWV) is the gold standard for noninvasive arterial stiffness assessment, an independent predictor of cardiovascular disease, and a potential parameter to guide therapy. However, cfPWV is not routinely measured in clinical practice due to the unavailability of a low-cost, operator-friendly, and independent device. The current study validated a novel laser Doppler vibrometry (LDV)-based measurement of cfPWV against the reference technique. METHODS: In 100 (50 men) hypertensive patients, cfPWV was measured using applanation tonometry (Sphygmocor) and the novel LDV device. This device has 2 handpieces with 6 laser beams each that simultaneously measure vibrations from the skin surface at carotid and femoral sites. Pulse wave velocity is calculated using ECG for the identification of cardiac cycles. An ECG-independent method was also devised. Cardiovascular risk score was calculated for patients between 40 and 75 years old using the WHO risk scoring chart. RESULTS: LDV-based cfPWV correlated significantly with tonometry (r=0.86, P <0.0001 ECG-dependent [cfPWV LDV_ECG ] and r=0.80, P <0.001 ECG-independent [cfPWV LDV_w/oECG ] methods). Bland-Altman analysis showed nonsignificant bias (0.65 m/s) and acceptable SD (1.27 m/s) between methods. Intraobserver coefficient of variance for LDV was 4.7% (95% CI, 3.0%–5.5%), and interobserver coefficient of variance was 5.87%. CfPWV correlated significantly with CVD risk (r=0.64, P <0.001; r=0.41, P =0.003; and r=0.37, P =0.006 for tonometry, LDV-with, and LDV-without ECG, respectively). CONCLUSIONS: The study demonstrates clinical validity of the LDV device. The LDV provides a simple, noninvasive, operator-independent method to measure cfPWV for assessing arterial stiffness, comparable to the standard existing techniques. REGISTRATION: URL: https://clinicaltrials.gov/study/NCT03446430 ; Unique identifier: NCT03446430.

22 June 2020 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
Yanlu LiYanlu Li
Yanlu Li
LMLouise Marais
Louise Marais
HKHakim Khettab
Hakim Khettab
ZQZhiheng Quan
Zhiheng Quan
SASoren Aasmul
Soren Aasmul
Roel BaetsRoel Baets
Roel Baets
Pulse wave velocity (PWV) is a reference measure for aortic stiffness, itself an important biomarker of cardiovascular risk. To enable low-cost and easy-to-use PWV measurement devices that can be used in routine clinical practice, we have designed several handheld PWV sensors using miniaturized laser Doppler vibrometer (LDV) arrays in a silicon photonics platform. The LDV-based PWV sensor design and the signal processing protocol to obtain pulse transit time (PTT) and carotid-femoral PWV in a feasibility study in humans, are described in this paper. Compared with a commercial reference PWV measurement system, measuring arterial pressure waveforms by applanation tonometry, LDV-based displacement signals resulted in more complex signals. However, we have shown that it is possible to identify reliable fiducial points for PTT calculation using the maximum of the 2nd derivative algorithm in LDV-based signals, comparable to those obtained by the reference technique, applanation tonometry.

1 April 2019 in Optics Letters
Verified
Journal Article
Closed access
PDF file
JZJinghao Zhu
Jinghao Zhu
Yanlu LiYanlu Li
Yanlu Li
Roel BaetsRoel Baets
Roel Baets
We present a scanning average method used in laser Doppler vibrometry systems for mitigating the noise induced by dynamic speckles. In this method, the measurement beam is scanned over the target surface within the area of interest at a relatively high frequency. Then an averaging operation (e.g., low-pass filtering) is applied to the acquired photocurrent signals to remove the impacts of the scan. Movement signals recovered from the averaged photocurrents turn out to have lower speckle-induced noise. We report the experimental demonstration of this technique through the use of a silicon-based photonic integrated circuit.

2 March 2021 in Optics Express
Verified
Journal Article
Open access
PDF file
Yanlu LiYanlu Li
Yanlu Li
Roel BaetsRoel Baets
Roel Baets
A variety of mechanisms can induce distortions in the output signals of a homodyne laser Doppler vibrometer (LDV). In this paper, the nonlinear LDV distortions caused by a strong second-order ghost reflection originating from lens flares are theoretically explained and analyzed. We propose a simple compensation method to mitigate this distortion. The performance and limitations of this method are also explained both in simulation and in experiment.