The paper presents the outcomes of an experimental program developed and carried out with the aim of characterizing the behavior of two types of moment-resisting joints in multistory frames of concrete-filled high-strength steel rectangular hollow section (RHS) columns and mild carbon steel beams. The paper describes the design approach and displays the specific detailing for the two joint typologies: with reduced beam section (RBS) and with cover plates (CP). In spite of the various past and recent studies which were focused on the evaluation of full-strength welded beam-to-concrete-filled-tube (CFT) column joints, particular design procedures are missing at the European level. The objectives of the current research were to (1) development a design procedure for welded beam-to-CF-RHS joints, (2) experimental validation of the of the design procedure, and (3) assessment of the seismic performance. The monotonic and cyclic tests evidenced a good conception and design of the RBS and CP joints. In particular, the current study proved the feasibility of using higher steel grades in columns and joint components, and the use of an external diaphragm for the transfer the loads from the beam to the side walls of the RHS steel tube. The seismic performance of the joints was proved adequate, the joints sustaining rotation capacities larger than the 40 mrad at the significant damage performance level.
Within the last decade, much attention has been focused on determining viable techniques for producing sustainable asphalt mixtures and minimizing fuel use and greenhouse gas emissions. Thus, warm mix asphalt (WMA) has become a topic of significant interest among road specialists as it offers a potential solution for reducing the environmental impact of the asphalt mixtures due to the decreased temperatures they require for mixing and compaction compared to hot mix asphalt (HMA). The present study is focused on the Life Cycle Assessment (LCA), according to a “Cradle-to-Gate” approach, of hot mix asphalt and warm mix asphalt prepared with locally available materials and different warm mix additives such as organic additives, chemical additive, and synthetic zeolite. For the analysis of the environmental impact of the warm mix asphalts was used a dedicated software for modeling and evaluating the LCA. The WMA prepared with chemical additive or organic additive led to a decrease of the environmental impact, in the production phase, compared to HMA. The study reveals that the raw materials extraction has the greatest impact on the environment in all studied cases, followed by the actual production phase of the asphalt mixture. For WMA produced with additives there was a decrease in the global impact on the environment compared to HMA.
The paper presents the outcome of a finite-element numerical investigation program developed and carried out in connection to a set of experimental investigations performed on welded beam-to-column joints, with columns realized as concrete-filled tubes (CFT) with rectangular hollow sections (RHS). The current study was aimed to calibrate a set of numerical models, to conduct a parametric study, and to validate the proposed design procedure. Joint models were calibrated, and additional parameters were investigated numerically, such as: influence of the concrete core, influence of the axial force in the column, response of one-way and two-way joints. It was shown that (1) the influence of concrete core was proved to be low for the single sided RBS or CP joint assemblies, but significant corresponding to joints with strengthened beam, (2) the response of the joint assembly was not affected by the presence of the axial compression force in the column, and (3) the connection solution with external diaphragms was characterized by an adequate response considering one-way and two-way joints. The current study evidenced a good conception and design of the reduced beam section (RBS) and cover plate (CP) joints. In particular, the study proved the feasibility of using higher steel grades in columns and joint components, and the use of an external diaphragm for the transfer the loads from the beam to the side walls of the rectangular hollow section (RHS) steel tube.
Eccentrically braced frames are well known for their capacity of dissipating seismic energy by plastic hinge formation in the so called ‘link elements’, which represent the dissipative devices of the eccentrically braced frame. The link element can be short, which means it will be mainly subjected to shear forces; long being mainly subjected to bending moment or intermediate in length subjected to a combined action of shear force-bending moment. The current study is focused on the calibration of existing experimental results with numerical finite element models of steel eccentrically braced frames with short link elements and a subsequent parametrical study considering different link lengths and multiple stiffeners along the link web panel.