Hugo Mora-Sanchez

Dr. Hugo Mora-Sanchez

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2022 in Journal of Magnesium and Alloys
Verified
Journal Article
Open access
MDMorteza Daavari
Morteza Daavari
MAMasoud Atapour
Masoud Atapour
Marta MohedanoMarta Mohedano
Marta Mohedano
HMHugo Mora-Sanchez
Hugo Mora-Sanchez
JRJuan Rodríguez-Hernández
Juan Rodríguez-Hernández
ATAboozar Taherizadeh
Aboozar Taherizadeh

2 February 2024 in Materials
Verified
Journal Article
Open access
PDF file
HMHugo Mora-Sanchez
Hugo Mora-Sanchez
MCMiguel Collado-Vian
Miguel Collado-Vian
Marta MohedanoMarta Mohedano
Marta Mohedano
Raúl ArrabalRaúl Arrabal
Raúl Arrabal
EMEndzhe Matykina
Endzhe Matykina
The present work aims to provide corrosion performance data for an additively manufactured Ti6Al4V alloy in saline and polluted environments. The as-received additively manufactured material underwent heat treatment at 850 °C for 3 h to transform the acicular α’ microstructure into a lamellar α microstructure. Comparative corrosion assessments were conducted between the heat-treated substrates, the as-received condition, and a conventionally mill-annealed alloy. Potentiodynamic polarization experiments were carried out in saline (3.5 wt.% NaCl) and acid aqueous media ((NH4)2SO4 containing Harrison’s solution). The corrosion performance of additively manufactured substrates matched or surpassed that of the conventional alloy in Harrison’s solutions while remaining inferior in saline medium, despite forming a thicker passive film. Overall, the XY plane showed better corrosion performance, particularly after the elimination of the acicular α’ martensite by the applied heat treatment. The results also suggested that the presence of the coarse β phase was beneficial in 3.5 wt.% NaCl solution and detrimental in Harrison’s solutions, more so in acidified and fluorinated conditions.

18 October 2022 in Coatings
Verified
Journal Article
Open access
PDF file
HMHugo Mora-Sanchez
Hugo Mora-Sanchez
FPFlorian Pixner
Florian Pixner
Ricardo BuzolinRicardo Buzolin
Ricardo Buzolin
Marta MohedanoMarta Mohedano
Marta Mohedano
Raúl ArrabalRaúl Arrabal
Raúl Arrabal
EMEndzhe Matykina
Endzhe Matykina
The objective of this work is to study for the first time the combination of electron beam (EB) surface structuring and plasma electrolytic oxidation (PEO) with the aim of providing a multiscale topography and bioactive surface to the Ti6Al4V alloy for biomedical applications. Ca and P-containing coatings were produced via 45 s PEO treatments over multi-scale EB surface topographies. The coatings morphology and composition were characterized by a means of scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). The effect on the previous EB topography was evaluated by means of a 3D optical profilometry and electrochemical response via potentiodynamic polarization tests. In general, the PEO process, morphology, composition and growth rate of the coatings were almost identical, irrespective of the topography treated. Minimal local differences were found in terms of morphology, and the growth rate were related to specific topographical features. Nevertheless, all the PEO-coated substrates presented essentially the same corrosion resistance. Electrochemical tests revealed a localized crevice corrosion susceptibility of all the bare EB topographies, which was successfully prevented after the PEO treatment.

16 May 2021 in Materials Proceedings
Verified
Conference Paper
Open access
PDF file
HMHugo Mora-Sanchez
Hugo Mora-Sanchez
Marta MohedanoMarta Mohedano
Marta Mohedano
Raúl ArrabalRaúl Arrabal
Raúl Arrabal
EMEndzhe Matykina
Endzhe Matykina
Innovative 3D metal additive manufacturing (AM) techniques are revolutionizing the biomedical industry, since they enable the production of porous structures and patient-customized parts of biomedical-grade materials, such as Ti alloys. Surface treatment via the plasma electrolytic oxidation (PEO) of conventionally manufactured Ti and its alloys has been proved as an outstanding approach to promote the osseointegration of implants. Henceforth, it is of increasing interest to develop PEO treatments for AM Ti alloys. The objective of the present work was to fabricate Ca and P containing thin (~3–10 μm thickness) PEO coatings on a Ti6Al4V alloy manufactured via direct metal laser sintering (DMLS), a laser powder bed fusion AM technique, and to study the electrochemical behavior of the treated specimens in a modified α-MEM solution. The electrical response of the PEO process on the AM alloy was compared to that on wrought mill-annealed Ti6Al4V sheets. The electrochemical behavior of the PEO-treated AM alloy was evaluated via potendiodynamic polarization and electrochemical impedance spectroscopy (EIS) in comparison to the non-treated AM alloy and the PEO-treated conventional counterparts. The surface degradation morphologies were evaluated by electron-optical microscopy and optical profilometry. The effect of the AM microstructure on the PEO process and the microstructure and electrochemical response of the resultant coatings are discussed with the aim to define future research directions relevant to the improvement of the corrosion resistance of AM Ti6Al4V, particularly with regard to pitting corrosion.