Luz Antonio Aguilera-Cortés

Dr. Luz Antonio Aguilera-Cortés


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2016 in Sensors
Verified
Journal Article
Open access
PDF file
Agustín Leobardo Herrera-MayAgustín Leobardo Herrera-May
Agustín Leobardo Herrera-May
JSJuan Carlos Soler-Balcazar
Juan Carlos Soler-Balcazar
Hector Vazquez-LealHector Vazquez-Leal
Hector Vazquez-Leal
JMJaime Martinez-Castillo
Jaime Martinez-Castillo
AVAnd Marco Osvaldo Vigueras-Zúñiga
And Marco Osvaldo Vigueras-Zúñiga
LALuz Antonio Aguilera-Cortés
Luz Antonio Aguilera-Cortés
Microelectromechanical systems (MEMS) resonators have allowed the development of magnetic field sensors with potential applications such as biomedicine, automotive industry, navigation systems, space satellites, telecommunications and non-destructive testing. We present a review of recent magnetic field sensors based on MEMS resonators, which operate with Lorentz force. These sensors have a compact structure, wide measurement range, low energy consumption, high sensitivity and suitable performance. The design methodology, simulation tools, damping sources, sensing techniques and future applications of magnetic field sensors are discussed. The design process is fundamental in achieving correct selection of the operation principle, sensing technique, materials, fabrication process and readout systems of the sensors. In addition, the description of the main sensing systems and challenges of the MEMS sensors are discussed. To develop the best devices, researches of their mechanical reliability, vacuum packaging, design optimization and temperature compensation circuits are needed. Future applications will require multifunctional sensors for monitoring several physical parameters (e.g., magnetic field, acceleration, angular ratio, humidity, temperature and gases).

22 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
LMLuis Angel Velosa Moncada
Luis Angel Velosa Moncada
LALuz Antonio Aguilera-Cortés
Luz Antonio Aguilera-Cortés
MGMax A. González-Palacios
Max A. González-Palacios
JRJean-Pierre Raskin
Jean-Pierre Raskin
Agustín Leobardo Herrera-MayAgustín Leobardo Herrera-May
Agustín Leobardo Herrera-May
Primary tumors of patients can release circulating tumor cells (CTCs) to flow inside of their blood. The CTCs have different mechanical properties in comparison with red and white blood cells, and their detection may be employed to study the efficiency of medical treatments against cancer. We present the design of a novel MEMS microgripper with rotatory electrostatic comb-drive actuators for mechanical properties characterization of cells. The microgripper has a compact structural configuration of four polysilicon layers and a simple performance that control the opening and closing displacements of the microgripper tips. The microgripper has a mobile arm, a fixed arm, two different actuators and two serpentine springs, which are designed based on the SUMMiT V surface micromachining process from Sandia National Laboratories. The proposed microgripper operates at its first rotational resonant frequency and its mobile arm has a controlled displacement of 40 µm at both opening and closing directions using dc and ac bias voltages. Analytical models are developed to predict the stiffness, damping forces and first torsional resonant frequency of the microgripper. In addition, finite element method (FEM) models are obtained to estimate the mechanical behavior of the microgripper. The results of the analytical models agree very well respect to FEM simulations. The microgripper has a first rotational resonant frequency of 463.8 Hz without gripped cell and it can operate up to with maximum dc and ac voltages of 23.4 V and 129.2 V, respectively. Based on the results of the analytical and FEM models about the performance of the proposed microgripper, it could be used as a dispositive for mechanical properties characterization of circulating tumor cells (CTCs).

19 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
NPNéstor N. Peña-García
Néstor N. Peña-García
LALuz Antonio Aguilera-Cortés
Luz Antonio Aguilera-Cortés
MGMax A. González-Palacios
Max A. González-Palacios
JRJean-Pierre Raskin
Jean-Pierre Raskin
Agustín Leobardo Herrera-MayAgustín Leobardo Herrera-May
Agustín Leobardo Herrera-May
New mobile devices need microphones with a small size, low noise level, reduced cost and high stability respect to variations of temperature and humidity. These characteristics can be obtained using Microelectromechanical Systems (MEMS) microphones, which are substituting for conventional electret condenser microphones (ECM). We present the design and modeling of a capacitive dual-backplate MEMS microphone with a novel circular diaphragm (600 µm diameter and 2.25 µm thickness) supported by fifteen polysilicon springs (2.25 µm thickness). These springs increase the effective area (86.85% of the total area), the linearity and sensitivity of the diaphragm. This design is based on the SUMMiT V fabrication process from Sandia National Laboratories. A lumped element model is obtained to predict the electrical and mechanical behavior of the microphone as a function of the diaphragm dimensions. In addition, models of the finite element method (FEM) are implemented to estimate the resonance frequencies, deflections, and stresses of the diaphragm. The results of the analytical models agree well with those of the FEM models. Applying a bias voltage of 3 V, the designed microphone has a bandwidth from 31 Hz to 27 kHz with 3 dB sensitivity variation, a sensitivity of 34.4 mV/Pa, a pull-in voltage of 6.17 V and a signal to noise ratio of 62 dBA. The results of the proposed microphone performance are suitable for mobile device applications.

25 June 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
MLMiguel Lara-Castro
Miguel Lara-Castro
AHAdrian Herrera-Amaya
Adrian Herrera-Amaya
MEMarco A. Escarola-Rosas
Marco A. Escarola-Rosas
MVMoises Vazquez-Toledo
Moises Vazquez-Toledo
FLFrancisco Lopez
Francisco Lopez
Agustín Leobardo Herrera-MayAgustín Leobardo Herrera-May
Agustín Leobardo Herrera-May
Endoscopic optical-coherence tomography (OCT) systems require low cost mirrors with small footprint size, out-of-plane deflections and low bias voltage. These requirements can be achieved with electrothermal actuators based on microelectromechanical systems (MEMS). We present the design and modeling of polysilicon electrothermal actuators for a MEMS mirror (100 μm × 100 μm × 2.25 μm). These actuators are composed by two beam types (2.25 μm thickness) with different cross-section area, which are separated by 2 μm gap. The mirror and actuators are designed through the Sandia Ultra-planar Multi-level MEMS Technology V (SUMMiT V®) process, obtaining a small footprint size (1028 μm × 1028 µm) for actuators of 550 µm length. The actuators have out-of-plane displacements caused by low dc voltages and without use material layers with distinct thermal expansion coefficients. The temperature behavior along the actuators is calculated through analytical models that include terms of heat energy generation, heat conduction and heat energy loss. The force method is used to predict the maximum out-of-plane displacements in the actuator tip as function of supplied voltage. Both analytical models, under steady-state conditions, employ the polysilicon resistivity as function of the temperature. The electrothermal-and structural behavior of the actuators is studied considering different beams dimensions (length and width) and dc bias voltages from 0.5 to 2.5 V. For 2.5 V, the actuator of 550 µm length reaches a maximum temperature, displacement and electrical power of 115 °C, 10.3 µm and 6.3 mW, respectively. The designed actuation mechanism can be useful for MEMS mirrors of different sizes with potential application in endoscopic OCT systems that require low power consumption.

25 August 2011 in Sensors
Verified
Journal Article
Open access
PDF file
Agustín Leobardo Herrera-MayAgustín Leobardo Herrera-May
Agustín Leobardo Herrera-May
LALuz Antonio Aguilera-Cortés
Luz Antonio Aguilera-Cortés
Hector Plascencia-MoraHector Plascencia-Mora
Hector Plascencia-Mora
ÁRÁngel L. Rodríguez-Morales
Ángel L. Rodríguez-Morales
Jian LUJian LU
Jian LU
Multilayered microresonators commonly use sensitive coating or piezoelectric layers for detection of mass and gas. Most of these microresonators have a variable cross-section that complicates the prediction of their fundamental resonant frequency (generally of the bending mode) through conventional analytical models. In this paper, we present an analytical model to estimate the first resonant frequency and deflection curve of single-clamped multilayered microresonators with variable cross-section. The analytical model is obtained using the Rayleigh and Macaulay methods, as well as the Euler-Bernoulli beam theory. Our model is applied to two multilayered microresonators with piezoelectric excitation reported in the literature. Both microresonators are composed by layers of seven different materials. The results of our analytical model agree very well with those obtained from finite element models (FEMs) and experimental data. Our analytical model can be used to determine the suitable dimensions of the microresonator’s layers in order to obtain a microresonator that operates at a resonant frequency necessary for a particular application.

5 November 2013 in Sensors
Verified
Journal Article
Open access
PDF file
RJRaul Juárez-Aguirre
Raul Juárez-Aguirre
SDSaúl Domínguez-Nicolás
Saúl Domínguez-Nicolás
EMElias Manjarrez
Elias Manjarrez
JTJesús A. Tapia
Jesús A. Tapia
EFEduard Figueras
Eduard Figueras
Agustín Leobardo Herrera-MayAgustín Leobardo Herrera-May
Agustín Leobardo Herrera-May
We present a signal processing system with virtual instrumentation of a MEMS sensor to detect magnetic flux density for biomedical applications. This system consists of a magnetic field sensor, electronic components implemented on a printed circuit board (PCB), a data acquisition (DAQ) card, and a virtual instrument. It allows the development of a semi-portable prototype with the capacity to filter small electromagnetic interference signals through digital signal processing. The virtual instrument includes an algorithm to implement different configurations of infinite impulse response (IIR) filters. The PCB contains a precision instrumentation amplifier, a demodulator, a low-pass filter (LPF) and a buffer with operational amplifier. The proposed prototype is used for real-time non-invasive monitoring of magnetic flux density in the thoracic cage of rats. The response of the rat respiratory magnetogram displays a similar behavior as the rat electromyogram (EMG).