In a random laser (RL), optical feedback arises from multiple scattering instead of conventional mirrors. RLs generate a laser-like emission, and meanwhile take advantage of a simpler and more flexible laser configuration. The applicability of RLs as light sources and optical sensors has been proved. These applications have been extended to the biological field, with tissues as natural scattering materials. Herein, the current state of the RL properties and applications was reviewed.
Laser surgery provides clean, fast and accurate cutting of tissue. However, it is difficult to detect what kind of tissue is being cut. Therefore, a wrong cut may lead to iatrogenic damage of structures. A feedback system should automatically stop the cutting process when a nerve is reached or accidentally being cut to prevent its damage. This could increase the applicability and safety of using a laser scalpel in surgical procedures. In this study, random lasing (RL) is used to differentiate between skin, fat, muscle and nerve tissue. Among these tissue types, a special emphasis is made on the differentiation of nerve from the rest of the tissues, especially fat since nerve is covered by a fatty layer. The differentiation is done for ex-vivo tissues of a pig animal model. The results show that random lasing can be used to differentiate these tissue types also under room light conditions in open air.
In general, the measurement of the main three optical properties (µa, µs and g) in turbid media requires a very precise measurement of the total transmission (TT), the total reflection (TR) and the collimated transmission (CT). Furthermore, an inverse algorithm such as inverse adding doubling or inverse Monte-Carlo-simulations is required for the reconstruction of the optical properties. Despite many available methods, the error free measurement of the scattering coefficient or the g-factor still remains challenging. In this study, we present a way to directly calculate the scattering coefficient from the total and collimated transmission. To allow this, it can be shown that is proportional to for a wide range of optical properties if the sample is thick enough. Moreover, a set-up is developed and validated to measure the collimated transmission precisely.
The determination of the optical properties of a turbid medium is a major topic in the field of optics. Generally, they comprise the parameters µa, µs, g and n. There is, however, a lack of techniques for the direct determination of the scattering coefficient µs. This study, therefore, proposes the random laser (RL) as a tool to directly measure µs - and not . Evidence is found that it is possible to determine µs in the diffusive regime by means of the RL. Based on these findings, a local model of the RL is developed and presented in this study.
In this study, it is shown that the dynamics of the lasing threshold and the intensity saturation of a diffusive random laser can be visualized by one spectral feature: the peak wavelength shift (tunability). The varied ink concentration and pump energy were utilized to experimentally induce the peak shift and the lasing threshold dynamics. It was found that the peak wavelength progressively turns from blueshift to redshift upon crossing the lasing threshold. A unique random laser threshold regime instead of a threshold point is revealed. This threshold regime was also compared with those deduced from the replica symmetry breaking and the Lévy statistics, both are the state-of-the-art methods to predict the behavior of a complex system. All three results show the high agreement in terms of unveiling the lasing nature of the random lasers.
In recent years, the laser has become an important tool in hospitals. Laser surgery in particular has many advantages. However, there is still a lack of the understanding of the influence of the relevant parameters for laser surgery. In order to fill this gap, the parameters pulse frequency, use of an exhaustion system, air cooling, laser power, laser scan speed, laser line energy and waiting time between cuts were analysed by ANOVA using inter-animal variation as a benchmark. The quality of the cuts was quantized by a previously published scoring system. A total of 1710 cuts were performed with a $$\text {CO}_2$$ laser. Of the parameters investigated, laser power and scan speed have the strongest influence. Only the right combination of these two parameters allows good results. Other effects, such as the use of pulsed or continuous wave (CW) laser operation, or air cooling, show a small or negligible influence. By modulating only the laser power and scan speed, an almost perfect cut can be achieved with a $$\text {CO}_2$$ laser, regardless of the external cooling used or the laser pulse duration or repetition rate from CW to nanosecond pulses.