Moritz Späth

Mr. Moritz Späth


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
DNDongqin Ni
Dongqin Ni
MSMoritz Späth
Moritz Späth
FKFlorian Klämpfl
Florian Klämpfl
MHMartin Hohmann
Martin Hohmann
In a random laser (RL), optical feedback arises from multiple scattering instead of conventional mirrors. RLs generate a laser-like emission, and meanwhile take advantage of a simpler and more flexible laser configuration. The applicability of RLs as light sources and optical sensors has been proved. These applications have been extended to the biological field, with tissues as natural scattering materials. Herein, the current state of the RL properties and applications was reviewed.

19 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MHMartin Hohmann
Martin Hohmann
DHDamaris Hecht
Damaris Hecht
BLBenjamin Lengenfelder
Benjamin Lengenfelder
MSMoritz Späth
Moritz Späth
FKFlorian Klämpfl
Florian Klämpfl
MSMichael Schmidt
Michael Schmidt
In medical applications, hyper-spectral imaging is becoming more and more common. It has been shown to be more effective for classification and segmentation than normal RGB imaging because narrower wavelength bands are used, providing a higher contrast. However, until now, the fact that hyper-spectral images also contain information about the three-dimensional structure of turbid media has been neglected. In this study, it is shown that it is possible to derive information about the depth of inclusions in turbid phantoms from a single hyper-spectral image. Here, the depth information is encoded by a combination of scattering and absorption within the phantom. Although scatter-dominated regions increase the backscattering for deep vessels, absorption has the opposite effect. With this argumentation, it makes sense to assume that, under certain conditions, a wavelength is not influenced by the depth of the inclusion and acts as an iso-point. This iso-point could be used to easily derive information about the depth of an inclusion. In this study, it is shown that the iso-point exists in some cases. Moreover, it is shown that the iso-point can be used to obtain precise depth information.

21 October 2019 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
MSMoritz Späth
Moritz Späth
FKFlorian Klämpfl
Florian Klämpfl
FSFlorian Stelzle
Florian Stelzle
MHMartin Hohmann
Martin Hohmann
BLBenjamin Lengenfelder
Benjamin Lengenfelder
MSMichael Schmidt
Michael Schmidt
The laser has become an integral part of modern medicine, procedures based on this technique have found their way into a multitude of medical disciplines. There is, however, no data available on the detailed quantitative development of laser use in the medical sector. This fact gave rise to the idea of the present study, which analyzed the raw data of the quality report of German hospitals with respect to this subject. Over the 9 years of report, a steady increase in the cumulative number of cases was evident, although not all body regions in which the medical laser is used followed this trend. The CO2 laser was found to be the most commonly applied laser, even though a large spectrum of different laser types is used. Based on the present study, the importance of the laser for medical purposes can be confirmed.

17 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
BLBenjamin Lengenfelder
Benjamin Lengenfelder
MHMartin Hohmann
Martin Hohmann
MSMoritz Späth
Moritz Späth
Daniel ScherbaumDaniel Scherbaum
Daniel Scherbaum
MWManuel Weiß
Manuel Weiß
FKFlorian Klämpfl
Florian Klämpfl
The need for tissue contact makes photoacoustic imaging not applicable for special medical applications like wound imaging, endoscopy, or laser surgery. An easy, stable, and contact-free sensing technique might thus help to broaden the applications of the medical imaging modality. In this work, it is demonstrated for the first time that remote photoacoustic sensing by speckle analysis can be performed in the MHz sampling range by tracking a single speckle using a four quadrant photo-detector. A single speckle, which is created by self-interference of surface back-reflection, is temporally analyzed using this photo-detector. Phantoms and skin samples are measured in transmission and reflection mode. The potential for miniaturization for endoscopic application is demonstrated by fiber bundle measurements. In addition, sensing parameters are discussed. Photoacoustic sensing in the MHz sampling range by single speckle analysis with the four quadrant detector is successfully demonstrated. Furthermore, the endoscopic applicability is proven, and the sensing parameters are convenient for photoacoustic sensing. It can be concluded that a single speckle contains all the relevant information for remote photoacoustic signal detection. Single speckle sensing is therefore an easy, robust, contact-free photoacoustic detection technique and holds the potential for economical, ultra-fast photoacoustic sensing. The new detection technique might thus help to broaden the field of photoacoustic imaging applications in the future.

11 January 2021 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
MSMoritz Späth
Moritz Späth
MHMartin Hohmann
Martin Hohmann
MRMaximilian Rohde
Maximilian Rohde
BLBenjamin Lengenfelder
Benjamin Lengenfelder
FSFlorian Stelzle
Florian Stelzle
FKFlorian Klämpfl
Florian Klämpfl
Multiple diseases are associated with a wide spectrum of microvascular dysfunctions, microangiopathies and microcirculation disorders. Monitoring the microcirculation could thus be useful to diagnose many local and systemic circulatory disorders and to supervise critically ill patients. Many of the scores currently available to help identify the condition of a microcirculation disorder are invasive or leave scope for interpretation. Thus, the present study aims to investigate with Monte‐Carlo simulations (as numerical solutions of the radiative transfer equation) whether shifted position‐diffuse reflectance imaging (SP‐DRI), a non‐invasive diagnostic technique, reveals information on the capillary diameter to assess the state of the microcirculation. To quantify the SP‐DRI signal, the modulation parameter K is introduced. It proves to correlate almost perfectly with the capillary diameter (), making it a valid parameter for reliably assessing microcirculation. SP‐DRI is emerging as an important milestone on the way to early and conveniently diagnosing microcirculation associated diseases.

15 October 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MSMoritz Späth
Moritz Späth
MHMartin Hohmann
Martin Hohmann
CRClemens Roider
Clemens Roider
BLBenjamin Lengenfelder
Benjamin Lengenfelder
FSFlorian Stelzle
Florian Stelzle
FKFlorian Klämpfl
Florian Klämpfl
Due to significant advantages, the trend in the field of medical technology is moving towards minimally or even non-invasive examination methods. In this respect, optical methods offer inherent benefits, as does diffuse reflectance imaging (DRI). The present study attempts to prove the suitability of DRI—when implemented alongside a suitable setup and data evaluation algorithm—to derive information from anatomically correctly scaled human capillaries (diameter: $$10\,\upmu \hbox {m}$$ 10 μ m , length: $$45\,\upmu \hbox {m}$$ 45 μ m ) by conducting extensive Monte–Carlo simulations and by verifying the findings through laboratory experiments. As a result, the method of shifted position-diffuse reflectance imaging (SP-DRI) is established by which average signal modulations of up to 5% could be generated with an illumination wavelength of $$\lambda =424\,\hbox {nm}$$ λ = 424 nm and a core diameter of the illumination fiber of $$50\,\upmu \hbox {m}$$ 50 μ m . No reference image is needed for this technique. The present study reveals that the diffuse reflectance data in combination with the SP-DRI normalization are suitable to localize human capillaries within turbid media.