Leonie Schmohl

Ms. Leonie Schmohl


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2021 in Materials
Verified
Journal Article
Open access
PDF file
Andreas KoenigAndreas Koenig
Andreas Koenig
JSJulius Schmidtke
Julius Schmidtke
LSLeonie Schmohl
Leonie Schmohl
SSSibylle Schneider-Feyrer
Sibylle Schneider-Feyrer
MRMartin Rosentritt
Martin Rosentritt
SHSebastian Hahnel
Sebastian Hahnel
The performance of dental resin-based composites (RBCs) heavily depends on the characteristic properties of the individual filler fraction. As specific information regarding the properties of the filler fraction is often missing, the current study aims to characterize the filler fractions of several contemporary computer-aided design/computer-aided manufacturing (CAD/CAM) RBCs from a material science point of view. The filler fractions of seven commercially available CAD/CAM RBCs featuring different translucency variants were analysed using Scanning Electron Microscopy (SEM) with Energy Dispersive X-ray Spectroscopy (EDS), Micro-X-ray Computed Tomography (µXCT), Thermogravimetric Analysis (TG) and X-ray Diffractometry (XRD). All CAD/CAM RBCs investigated included midifill hybrid type filler fractions, and the size of the individual particles was clearly larger than the individual specifications of the manufacturer. The fillers in Shofu Block HC featured a sphericity of ≈0.8, while it was <0.7 in all other RBCs. All RBCs featured only X-ray amorphous phases. However, in Lava Ultimate, zircon crystals with low crystallinity were detected. In some CAD/CAM RBCs, inhomogeneities (X-ray opaque fillers or pores) with a size <80 µm were identified, but the effects were minor in relation to the total volume (<0.01 vol.%). The characteristic parameters of the filler fraction in RBCs are essential for the interpretation of the individual material’s mechanical and optical properties.

11 June 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
LSLeonie Schmohl
Leonie Schmohl
Anuschka Josephine RoesnerAnuschka Josephine Roesner
Anuschka Josephine Roesner
FFFlorian Fuchs
Florian Fuchs
MWMaximilian Wagner
Maximilian Wagner
MSMichael Benno Schmidt
Michael Benno Schmidt
Andreas KoenigAndreas Koenig
Andreas Koenig
Acid resistance of CAD/CAM resin composites. Erosion-related tooth surface loss is closely related to acid exposure, such as contact with acidic beverages or disease-related reflux. As a result, dental restorations in affected patients are also exposed to acids, which indicates that the performance and longevity of a dental restoration is impacted by the acid resistance of the individually employed restorative materials. However, unlike for ceramic materials, the acid resistance of CAD/CAM resin composites is not commonly evaluated by the manufacturers, and no standardised test methods have yet been established. Against this background, the present in vitro study aimed to examine the long-term resistance of CAD/CAM resin composites (Brilliant Crios, Cerasmart, Grandio blocs, Lava Ultimate, Shofu Block HC) against three acidic media (tonic water, acetic acid, hydrochloric acid) as well as demineralized water and to investigate potential damage mechanisms. Changes in surface roughness (Sa) were detected by confocal laser scanning microscopy (CLSM), and changes in surface hardness were measured using Vickers hardness (HV). The damage mechanisms were analysed by scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS) and micro X-ray computer tomography (µXCT). For each material, few changes in either Sa or HV were identified for at least one of the different media; for Cerasmart, the sharpest deterioration in surface properties was observed. SEM–EDS revealed leaching of barium, aluminium, and titanium from fillers in a 2 µm zone on the rough but not on the polished surface of the specimen. Within the limitations of the current study, it can be concluded that polished CAD/CAM resin composites can be recommended for clinical use in patients with erosive conditions.

Verified
Journal Article
Open access
PDF file
OSOliver Schierz
Oliver Schierz
LSLeonie Schmohl
Leonie Schmohl
SHSebastian Hahnel
Sebastian Hahnel
ARAngelika Rauch
Angelika Rauch
Compared to thermoplastic manufacturing techniques, computer-aided design (CAD) and computer-aided manufacturing (CAM) technologies make it easier to process modern restorative and prosthetic materials with improved material properties. In dentistry, tooth-colored alternatives to metal-based frameworks for application in removable dental prostheses (RDP) emerged. With regard to this aspect, the current article provides an overview of the specific material properties of polyoxymethylene (POM). Furthermore, it reviews scientific literature indexed in PubMed and Web of Science that focuses on RDPs fabricated from POM within the last 10 years. Finally, a prosthetic rehabilitation of a patient with a RDP fabricated from POM is illustrated and observations during a follow-up over 10 months are described. Scientific data and clinical observations indicate that polyoxymethylene is a promising material that bridges gaps in dental therapeutic options. While survival time may be limited due to wear, POM might be a favorable option for application in semi-permanent restorations.

26 November 2021 in Biomedicines
Verified
Journal Article
Open access
PDF file
MRMartin Rosentritt
Martin Rosentritt
SSSibylle Schneider-Feyrer
Sibylle Schneider-Feyrer
TSThomas Strasser
Thomas Strasser
Andreas KoenigAndreas Koenig
Andreas Koenig
LSLeonie Schmohl
Leonie Schmohl
Alois SchmidAlois Schmid
Alois Schmid
New resin-based composites and resin-infiltrated ceramics are used to fabricate computer-aided design (CAD) and computer-aided manufacturing (CAM)-based restorations, although little information is available on the long-term performance of these materials. The aim of this investigation was to determine the effects of storage time (24 h, 90 days, 180 days) on the thermophysical properties of resin-based CAD/CAM materials. Thermogravimetric Analysis (TGA), differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA) were used in the study. TGA provided insight into the composition of the resin-based materials and the influence of internal plasticization and water sorption. Resin-based composites showed different decomposition, heat energy and mechanical behavior, which was influenced by storage time in water. Individual materials such as Grandio bloc showed lower influence of water storage while maintaining good mechanical properties.

29 November 2023 in Polymers
Verified
Journal Article
Open access
PDF file
RRRosello Jimenez Jan Raffael
Rosello Jimenez Jan Raffael
FFFlorian Fuchs
Florian Fuchs
LSLeonie Schmohl
Leonie Schmohl
MSMichaela Schulz-Siegmund
Michaela Schulz-Siegmund
Andreas KoenigAndreas Koenig
Andreas Koenig
Three-dimensional (3D)-printed occlusal splints are becoming more prevalent in the treatment of tooth substance loss due to their fast and cost-effective production. The purpose of this in vitro study was to investigate whether the mechanical properties (tensile strength—TS, modulus of elasticity in tension—ME, and Vickers hardness—HV) vary between the materials (printed dimethacrylate-based resins: Keyprint KeySplint soft—KEY, Luxaprint Ortho Plus—LUX, V-Print splint—VPR, printed methacrylate-based resins Freeprint splint 2.0—FRE, and milled methacrylate-based material, CLEAR splint—CLE), and the influence of aging processes (extraoral storage conditions and nightly or daily use) was examined. The printed methacrylate-based resins (FRE, LUX, and VPR) had much higher TS (43.7–48.5 MPa compared to 12.3–13.3 MPa), higher ME (2.01–2.37 GPa compared to 0.43–0.72 GPa), and higher HV (11.8–15.0 HV compared to 3.3–3.5 HV) than both of the methacrylate-based resins (KEY and CLE) after the production process. Although the TS, ME, and HV of the printed dimethacrylate resins (FRE, LUX, and VPR) decreased significantly under humid conditions with possibly elevated temperatures (thermocycling as well as 37 °C), these mechanical properties were significantly higher than both methacrylate-based resins (KEY and CLE). Therefore, printed dimethacrylate resins should be used rather than methacrylate-based resins for high expected masticatory forces, low wall thicknesses, or very long wearing times (≥6 months).

9 March 2024 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
JKJulia Kreitczick
Julia Kreitczick
LSLeonie Schmohl
Leonie Schmohl
SHSebastian Hahnel
Sebastian Hahnel
KVKETPAT VEJJASILPA
KETPAT VEJJASILPA
MSMichaela Schulz-Siegmund
Michaela Schulz-Siegmund
Andreas KoenigAndreas Koenig
Andreas Koenig
The influence of various aging protocols, representing and accelerating influences present in the dental context, on possible changes in the microstructure and mechanical properties of thermoplastics was investigated. In order to minimize the complexity of the systems, first pure polymers and then later the equivalent dental polymeric materials were analyzed. Pure polymers (Poly(methyl methacrylate) - PMMA, Polyoxymethylene homopolymer - POM-H, Polyether ether ketone - PEEK, Nylon 12 - PA12, Polypropylene - PP) were analyzed before as well as after applying different aging protocols relevant to the oral environment (ethanol, thermocycling, alkaline and acidic setting) by differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). The thermoanalytical parameters used were glass transition temperature (Tg), melting peak and crystallization peak temperature (Tpm, Tpc) and decomposition behavior. In a second step selected commercially available dental products (Telio CAD - PMMAD, Zirlux Acetal - POMD, Juvora Natural Dental Disc - PEEKD) aged by the protocol that previously showed strong effects were examined and additionally tested for changes in their Vickers and Martens hardness by Mann-Whitney-U test. The combinations of pure polymers and viable aging protocols analyzed within this study were identified via TGA or DSC as PA12 & thermocycling, POM-H & denture cleanser/lactic acid/ethanol, PP & lactic acid. The dental polymeric materials PMMAD and POMD due to aging in lactic acid showed slight but significantly (p < 0.01) reduced Vickers and partly Martens hardness. PEEK showed the greatest material resistance within this study.