One of the important aspects of realizing smart cities is developing smart homes/buildings and, from the energy perspective, designing and implementing an efficient smart home area energy management system (HAEMS) is vital. To be effective, the HAEMS should include various electrical appliances as well as local distributed/renewable energy resources and energy storage systems, with the whole system as a microgrid. However, the collecting and processing of the data associated with these appliances/resources are challenging in terms of the required sensors/communication infrastructure and computational burden. Thanks to the internet-of-things and cloud computing technologies, the physical requirements for handling the data have been provided; however, they demand suitable optimization/management schemes. In this article, a HAEMS is developed using cloud services to increase the accuracy and speed of the data processing. A management protocol is proposed that provides an optimal schedule for a day-ahead operation of the electrical equipment of smart residential homes under welfare indicators. The proposed system comprises three layers: (1) sensors associated with the home appliances and generation/storage units, (2) local fog nodes, and (3) a cloud where the information is processed bilaterally with HAEMS and the hourly optimal operation of appliances/generation/storage units is planned. The neural network and genetic algorithm (GA) are used as part of the HAEMS program. The neural network is used to predict the amount of workload corresponding to users’ requests. Improving the load factor and the economic efficiency are considered as the objective function that is optimized using GA. Numerical studies are performed in the MATLAB platform and the results are compared with a conventional method.
In this paper, the optimal allocation problem of the Electric Vehicles Parking Lots and DG in micro‐grid is studied as a novel optimization problem. In the proposed problem, the different factors including the technical and the economic issues are considered for achieving a realistic solution. In addition, FACTS devices have been added to the network by considering the costs of installation, repair and maintenance, and their effecton the technical and economic parameters of the network has been investigated. Also, how to optimally charge and discharge storage devices and how to optimally inject active or reactive power by charging stations to improve energy management in the network has been studied. In order to evaluate the impact and reduce economic costs, the optimal number of distributed renewable energy, storage and FACTS equipment along with the optimal number of parking lots with Existence of different number of electric vehicles in the survey and microgrid network has been designed using a two‐stage optimization method. The method is simulated on the standard IEEE 33 bus. The results show that the optimal power factor of parking lots can be determined during the unloading of vehicles in such a way that the technical parameter of the network is improved.
30 September 2024 in IET Generation, Transmission & Distribution
The escalating global population and energy demands underscore the critical role of renewable energy sources, particularly solar power, in mitigating environmental degradation caused by traditional fossil fuels. This paper emphasizes the advantages of solar energy, especially photovoltaic (PV) systems, which have become pivotal in hybrid energy systems. However, accurate modelling and identification of PV cell parameters pose challenges, prompting the adoption of meta‐heuristic optimization algorithms. This work explores the limitations of existing algorithms and introduces a novel approach, the bio‐dynamics grasshopper optimization algorithm (BDGOA). The BDGOA addresses deficiencies in both exploration and exploitation phases, exhibiting exceptional convergence speed and efficiency. The algorithm's simplicity, achieved through the implementation of an elimination phase and controlled search space, enhances its performance without intricate calculations. The study evaluates the BDGOA by applying it to identify unknown parameters of five solar modules. The algorithm's effectiveness is demonstrated through the extraction of parameters for RTC France, PWP201, SM55, KC200GT, and SW255 models, validated against experimental data under diverse conditions. The paper concludes with insights into the impact of radiation and temperature on module parameters. The subsequent sections of the paper delve into the intricacies of the PV cell and module model, articulate the formulation of the proposed algorithm, present simulations, and analyse the obtained results. The BDGOA emerges as a promising solution, overcoming the limitations of existing algorithms and contributing significantly to the advancement of accurate and efficient PV cell parameter identification, thereby propelling progress towards a sustainable energy future.
Photovoltaic charging stations (PVCSs) are one of the most important pieces of charging equipment for electric vehicles (EVs). Recently, the process of designing solar charging stations as flexible sources has been growing and developing. This paper presents a relatively complete design of a solar charging station as a flexible economic resource in a 10-year planning horizon based on a genetic algorithm in two scenarios. PVCSs are not considered in the first scenario. This scenario is only to confirm the results, and the proposed method is proposed. However, in the second scenario, the effects of PVCSs and the demand response strategy (DR) on this development are considered. Copula probability distribution functions are used to create appropriate scenarios for vehicles during different planning years. The proposed energy management system shows a stable performance in terms of the annual load growth index and electricity price of each level of demand over the time horizon along with minimizing power losses and costs required, which makes PVCS efficiency higher and gives them a suitable structure and stability. The modeling results in terms of uncertainties in the system indicate that the use of load management along with PVCS design and flexible electric vehicle charge control strategies improves power quality parameters and optimizes system cost over a period of 10 years. Compared to the obtained results with the traditional case, it is observed that long-term planning in terms of DR and PVCSs and the technical specifications of the network have been improved. As a result of this proposed long-term planning, PVCSs are more flexible.
Power transformers are one of the most important parts of a power system, and they are crucial to the system's reliability and energy quality. The “health index” idea is used in this research to evaluate and classify transformers based on their conditions in order to optimize transformer upgrading and replacement decisions. And the transformer is inspected and maintained from various angles by collecting the transformer’s health factor and utilizing the number of this indicator to determine when and how often the transformer should be inspected and maintained. Finally, the health index described in this paper is utilized to review and regularly classify transformers based on their states and improve the renovation replacement method by applying the fuzzy logic method to research this coefficient precisely. The fuzzy health index used in this work has the advantage of being able to be trained using past transformer data. When the training is complete, it can be applied to other transformers, with the goal of achieving optimal functioning for transformers while considering cost and dependability. The specific results of the present article indicate that the health index criterion presented in this article has a high degree of certainty regarding the selection, arrangement, and timing of maintenance and service steps in the evaluated transformers. In addition, when comparing the proposed method to the conventional method for seven sample transformers, the system availability index of the proposed method improved by about 40%.It also had about 25% higher reliability than the conventional method for 7 sample transformers.