Mohsen Eskandari

Dr. Mohsen Eskandari

UNSW Sydney
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
ARAmin Rajabi
Amin Rajabi
Mohsen EskandariMohsen Eskandari
Mohsen Eskandari
MGMojtaba Jabbari Ghadi
Mojtaba Jabbari Ghadi
Li LiLi Li
Li Li
JZJiangfeng Zhang
Jiangfeng Zhang
PSPierluigi Siano
Pierluigi Siano

17 December 2018 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
BMBehnam Mahamedi
Behnam Mahamedi
Mohsen EskandariMohsen Eskandari
Mohsen Eskandari
JFJohn Fletcher
John Fletcher
Jian ZhuJian Zhu
Jian Zhu
Three-phase three-leg inverters comprise the majority of inverters that are integrated into power grids. They can develop positive- and negative-sequence components under unbalanced conditions including asymmetrical faults, but not zero sequence. This indicates that a sequence-based control strategy is required for a comprehensive control of inverter currents and voltages, hence positive- and negative-sequence components must be controlled separately with their own dedicated controllers. Given this critical need, a sequence-based control technique for grid-forming and grid-feeding inverter-interfaced distributed generators (IIDG) is proposed. As a necessary part of the fault ride-through (FRT) capability of IIDGs, a current limiter is developed which can limit inverter currents at a pre-defined threshold for both balanced and unbalanced faults/voltage sags. Whilst the current regulators work in the synchronous reference frame with simple PI controllers, the limiter works in natural reference frame and thus treats each phase current separately, which results in current limiting at the threshold for all phases. The advantage of the proposed limiter is that it virtually acts instantaneously such that the inverter current can be limited from the start of the disturbance. The simulation results in MATLAB/SIMULINK reveal promising performance of the proposed control strategy with the proposed current limiting.

4 September 2014 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
MMMohammad H. Moradi
Mohammad H. Moradi
Mohsen EskandariMohsen Eskandari
Mohsen Eskandari
SHS. Mahdi Hosseinian
S. Mahdi Hosseinian
Recently, microgrids (MGs) have attracted considerable attention as a high-quality and reliable source of electricity. In this paper, energy management in MGs is addressed in the light of economic efficiency, environmental restrictions, and reliability improvement via: 1) optimizing the type and capacity of distributed generation (DG) sources, as well as the capacity of storage devices (SD); and 2) developing an operational strategy (OS) for energy management in MGs. A master-slave objective function based on net present value (as an economic indicator) is proposed. Such objective function is solved using a hybrid optimization method. This method includes two steps. In the first step, 2-D slave object functions (SOFs), operating costs, and consumer outage cost (as a reliability index) are minimized by quadratic programming and particle swarm optimization (PSO) algorithms, respectively. Then Pareto curve is drawn for SOF and fuzzy logic is employed to select the best SOF solution, OS, from Pareto curve. In the second step, using the best OS from step one for any iteration, PSO algorithms employed to solve master objective function, and to determine the optimum capacity and type of DGs and SDs. The results show that the proposed framework can be considered as an efficient tool in planning and energy management of MGs.

12 October 2020 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Mohsen EskandariMohsen Eskandari
Mohsen Eskandari
Andrey SavkinAndrey Savkin
Andrey Savkin
Fault ride-through (FRT) is essential for inverter-interfaced distributed generation (IIDG) units to protect semiconductor switches from being imposed to overcurrent conditions while the transients are securely passed. To this end, a current limiting strategy is adopted for IIDG units, mostly embedded in control loops, to limit the current within the withstand-able band and to make the IIDG units stay connected to the (micro) grid during the transient. However, the FRT/current limiting of grid-forming inverters affects the transient stability of the autonomous droop-based microgrids and may make them unstable, which yet has not been well-explored in the literature. This issue is considered in this work through a scrupulous observation of the second-order nonlinear differential equation describing the frequency-phase angle dynamics and investigating the problem through the Lyapunov theory. The Chetaev’s instability theorem, which is developed based on the Lyapunov direct method, is used to explore the instability conditions due to the FRT. It is revealed that the phase angle variation, as a consequence of the current limiting, and the arbitrary/resistive transient impedance of grid-forming inverters make the system unstable. Numerical and time-domain results through Matlab/Simulink platform prove the validity of the models.

29 December 2022 in IEEE Transactions on Intelligent Vehicles
Verified
Journal Article
Closed access
Mohsen EskandariMohsen Eskandari
Mohsen Eskandari
Hailong HuangHailong Huang
Hailong Huang
Andrey SavkinAndrey Savkin
Andrey Savkin
WNWei Ni
Wei Ni
Intelligent vehicles need high bandwidth wireless communication links for safety and commercial communication. However, the new generations of wireless communication networks (WCNs), such as quasi-optic millimeter-wave (mmWave) (5G) and visible light optic (6G) WCNs, are exposed to blockage/scattering problems in highly dense (urban) areas. In this paper, we propose a reconfigurable intelligent surface (RIS)-equipped (unmanned aerial vehicle) UAV (RISeUAV) to secure an uninterrupted line-of-sight (LoS) communication link for an intelligent vehicle. The vehicle can be a smart ambulance and needs a stable high-speed link for autonomous navigation, also for continuous monitoring/diagnosing of the health condition of a patient. A two-stage method is proposed to address the NP-hardness and nonconvexity of planning an optimal trajectory for autonomous navigation of the RISeUAV limited to UAV motion and LoS constraints. In the first stage, the optimal tube path is determined by considering the energy consumption, LoS link, and UAV speed/acceleration constraints. In the second stage, an accurate RISeUAV trajectory is obtained through the secured tube path by considering the communication performance, passive beamforming, and nonholonomic constraint of the RISeUAV. Dynamic programming and successive convex approximation methods are used in the first and second stages, respectively. Simulation results show the accuracy/effectiveness of the method.

19 June 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Mohsen EskandariMohsen Eskandari
Mohsen Eskandari
Li LiLi Li
Li Li
MMM.H. Moradi
M.H. Moradi
PSPierluigi Siano
Pierluigi Siano
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg