To investigate the impact of trabecular bypass surgery targeted to angiographically determined high- vs. low-aqueous humor outflow areas on outflow facility (C) and intraocular pressure (IOP). Ex vivo comparative study. Postmortem ex vivo porcine and human eyes. Porcine (n = 14) and human (n = 13) whole globes were acquired. In both species, anterior segments were dissected, mounted onto a perfusion chamber, and perfused using Dulbecco's phosphate buffered solution containing glucose in a constant flow paradigm to achieve a stable baseline. Fluorescein was perfused into the anterior chamber and used to identify baseline segmental high- and low-flow regions of the conventional outflow pathways. The anterior segments were divided into 2 groups, and a 5 mm needle goniotomy was performed in either a high- or low-flow area. Subsequently, C and IOP were quantitatively reassessed and compared between surgery in baseline "high-flow" and "low-flow" region eyes followed by indocyanine green angiography. Outflow facility. In all eyes, high- and low-flow segments could be identified. Performing a 5-mm goniotomy increased outflow facility to a variable extent depending on baseline flow status. In the porcine high-flow group, C increased from 0.31 ± 0.09 to 0.39 ± 0.09 μL/mmHg/min (P = 0.12). In the porcine low-flow group, C increased from 0.29 ± 0.03 to 0.56 ± 0.10 μL/mmHg/min (P < 0.001). In the human high-flow group, C increased from 0.38 ± 0.20 to 0.41 ± 0.20 μL/mmHg/min (P = 0.02). In the human low-flow group, C increased from 0.25 ± 0.11 to 0.32 ± 0.11 μL/mmHg/min (<0.001). There was statistically significant greater increase in C for eyes where surgery was targeted to baseline low-flow regions in both porcine (0.07 ± 0.09 vs. 0.27 ± 0.13, P = 0.007 μL/mmHg/min, high vs low flow) and human eyes (0.03 ± 0.03 vs. 0.07 ± 0.02, P = 0.03 μL/mmHg/min, high vs. low flow). Targeting surgery to low-flow areas of the trabecular meshwork yields higher overall facility increase and IOP reduction compared to surgery in high-flow areas. Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
1 March 2023 in Investigative Ophthalmology & Visual Science
Purpose: To investigate differences in outflow facility between angiographically determined high- and low-flow segments of the conventional outflow pathway in porcine eyes. Methods: Porcine anterior segments (n = 14) were mounted in a perfusion chamber and perfused using Dulbecco's phosphate buffered solution with glucose. Fluorescein angiography was performed to determine high- and low-flow regions of the conventional outflow pathways. The trabecular meshwork (TM) was occluded using cyanoacrylate glue, except for residual 5-mm TM areas that were either high or low flow at baseline, designating these eyes as “residual high-flow” or “residual low-flow” eyes. Subsequently, outflow was quantitatively reassessed and compared between residual high-flow and residual low-flow eyes followed by indocyanine green angiography. Results: Fluorescein aqueous angiography demonstrated high-flow and low-flow regions. Baseline outflow facilities were 0.320 ± 0.08 and 0.328 ± 0.10 µL/min/mmHg (P = 0.676) in residual high-flow and residual low-flow eyes before TM occlusion, respectively. After partial trabecular meshwork occlusion, outflow facility decreased to 0.209 ± 0.07 µL/min/mmHg (−32.66% ± 19.53%) and 0.114 ± 0.08 µL/min/mmHg (−66.57% ± 23.08%) in residual high- and low-flow eyes (P = 0.035), respectively. There was a significant difference in the resulting IOP increase (P = 0.034). Conclusions: Angiographically determined high- and low-flow regions in the conventional outflow pathways differ in their segmental outflow facility; thus, there is an uneven distribution of local outflow facility across different parts of the TM.
1 September 2016 in Investigative Ophthalmology & Visual Science
Purpose: Recent histological data suggest autonomic innervation of the central retinal artery. In the present study, we investigated the effect of electrical brain stem stimulation at the superior salivatory nucleus (SSN) on the retinal vessel diameter in rats and whether nitric oxide mediates a possible effect. Methods: Sprague-Dawley rats (n = 12) were anesthetized using pentobarbital sodium (50 mg/kg intraperitoneally). The animals were artificially ventilated and the femoral artery and vein were cannulated for blood pressure measurement and drug administration. After a craniotomy was performed, a unipolar stainless steel electrode was inserted into the brainstem at the coordinates of the SSN. Stimulations were performed at 20 Hz, 9 μA, 1 ms pulse duration and 200 pulses. Retinal vessel diameters were measured continuously with the Imedos DVA-R, a noncontact fundus camera for rats with image analysis software. After control measurements, L-NAME, a nonspecific inhibitor of NO synthase, was applied intravenously (10 mg/kg), and the SSN stimulations were repeated. Results: Stimulation at the SSN coordinates increased the retinal arterial diameter by 6.41% ± 1.65% and the venous diameter by 3.48% ± 1.93% (both P < 0.05). Application of L-NAME reduced the arterial response significantly to 2.93% ± 0.91%, but did not change the venous response. Mean arterial pressure, carotid blood flow, and heart rate remained unaltered (by the stimulation). Conclusions: The present study demonstrates that the retinal circulation reacts to electric stimulation at the SSN coordinates in rats. Nitric oxide is involved in the response, but it is not the sole neurotransmitter.
1 July 2019 in Investigative Ophthalmology & Visual Science
Purpose: Episcleral venous pressure (EVP) greatly influences steady-state IOP and recent evidence suggests a neuronal influence on EVP. Yet little is known about the innervation of the episcleral circulation and, more specifically, the neurotransmitters involved. We identify possible neurotransmitter candidates in the episcleral circulation of rats. Methods: Eight immersion-fixated rat eyes taken from four animals were cut into serial sections, followed by standard immunohistochemistry. Antibodies against choline acetyltransferase, dopamine-β-hydroxylase, synaptophysine, PGP 9.5, VIP, neuronal nitric oxide synthase (nNOS), substance P, CGRP, and galanin were used. Additionally, colocalization experiments with smooth muscle actin and neurofilament (200 kDa) were performed. Results: In all specimens, the episcleral vessels showed immunoreactivity for smooth muscle actin and were reached by neurofilament (200 kDa)–positive structures. Furthermore, these structures colocalized with immunoreactivity for PGP 9.5, synaptophysine, choline acetyl transferase (ChAT), dopamine-β-hydroxylase, VIP, CGRP, nNOS, substance P and galanin. Conclusions: These findings indicate that there is neuronal input to the episcleral circulation. ChAT and VIP as well as dopamine-β-hydroxylase suggest parasympathetic and sympathetic innervation. Further studies are needed on whether the positively-stained structures are of functional significance for the regulation of the episcleral venous pressure and thereby IOP.
Précis: Trabecular meshwork (TM) pigmentation is not correlated with angiographically determined aqueous humor outflow (AHO) in an ex vivo perfusion model using human eyes. Purpose: To evaluate whether segmental TM pigmentation is correlated to segmental AHO in human eyes. Methods: Postmortem human eyes were acquired, and anterior segments were dissected. TM pigmentation was photographed 360-degrees around the eye. The anterior segments were then mounted onto a perfusion apparatus and perfused with Dulbecco’s phosphate buffered saline (DPBS) until a stabile baseline outflow facility was achieved. Aqueous angiography (AHO angiography) was performed using fluorescein (2%), and segmental AHO was documented around the limbus using an angiographic camera (Spectralis HRA+OCT). Circumferential and nasal TM pigmentation were compared with respective angiographic outflow imaging using a Pearson correlation analysis. Results: Segmental TM pigment distribution and segmental AHO were seen. TM pigment was statistically greatest in the inferior quadrant. AHO angiographic outflow was numerically greatest in the nasal quadrant, but this was not statistically significant. No statistically significant correlation was observed (r=−0.083, P=0.06) between segmental TM pigmentation and segmental AHO angiographic signal. Analyzing just the nasal quadrant, a significant weak negative correlation was found (r=−0.296, P=0.001). Discussion: Segmental TM pigmentation circumferentially around the eye is not a good proxy for segmental AHO circumferentially around the eye and should not be used to guide trabecular minimally invasive glaucoma surgeries.