Daniel Wanderer

Daniel Wanderer

Auto-generated profile, based on publicly available information

Daniel Wanderer

Hamilton Glaucoma Center, Shiley Eye Institute (X.Z., D.W., E.W., S.H.L., and A.S.H.), The Viterbi Family Department of Ophthalmology, University of California, San Diego, California, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2023 in Ophthalmology Glaucoma
Verified
Journal Article
Open access
CSClemens Strohmaier
Clemens Strohmaier
DWDaniel Wanderer
Daniel Wanderer
XZXiaowei Zhang
Xiaowei Zhang
DADevansh Agarwal
Devansh Agarwal
CTChristopher B. Toomey
Christopher B. Toomey
AHAlex S. Huang
Alex S. Huang
To investigate the impact of trabecular bypass surgery targeted to angiographically determined high- vs. low-aqueous humor outflow areas on outflow facility (C) and intraocular pressure (IOP). Ex vivo comparative study. Postmortem ex vivo porcine and human eyes. Porcine (n = 14) and human (n = 13) whole globes were acquired. In both species, anterior segments were dissected, mounted onto a perfusion chamber, and perfused using Dulbecco's phosphate buffered solution containing glucose in a constant flow paradigm to achieve a stable baseline. Fluorescein was perfused into the anterior chamber and used to identify baseline segmental high- and low-flow regions of the conventional outflow pathways. The anterior segments were divided into 2 groups, and a 5 mm needle goniotomy was performed in either a high- or low-flow area. Subsequently, C and IOP were quantitatively reassessed and compared between surgery in baseline "high-flow" and "low-flow" region eyes followed by indocyanine green angiography. Outflow facility. In all eyes, high- and low-flow segments could be identified. Performing a 5-mm goniotomy increased outflow facility to a variable extent depending on baseline flow status. In the porcine high-flow group, C increased from 0.31 ± 0.09 to 0.39 ± 0.09 μL/mmHg/min (P = 0.12). In the porcine low-flow group, C increased from 0.29 ± 0.03 to 0.56 ± 0.10 μL/mmHg/min (P < 0.001). In the human high-flow group, C increased from 0.38 ± 0.20 to 0.41 ± 0.20 μL/mmHg/min (P = 0.02). In the human low-flow group, C increased from 0.25 ± 0.11 to 0.32 ± 0.11 μL/mmHg/min (<0.001). There was statistically significant greater increase in C for eyes where surgery was targeted to baseline low-flow regions in both porcine (0.07 ± 0.09 vs. 0.27 ± 0.13, P = 0.007 μL/mmHg/min, high vs low flow) and human eyes (0.03 ± 0.03 vs. 0.07 ± 0.02, P = 0.03 μL/mmHg/min, high vs. low flow). Targeting surgery to low-flow areas of the trabecular meshwork yields higher overall facility increase and IOP reduction compared to surgery in high-flow areas. Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

20 June 2025 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
YHYe He
Ye He
RKRustum Karanjia
Rustum Karanjia
XZXiaowei Zhang
Xiaowei Zhang
DWDaniel Wanderer
Daniel Wanderer
EWEvan Walker
Evan Walker
AHAlex Huang
Alex Huang