Intravascular ultrasound has good prospects for clinical applications in sonothrombolysis. The catheter-based side-looking intravascular ultrasound thrombolysis (e.g., Ekosonic catheters) used in clinical studies has a high frequency (2 MHz). The lower-frequency ultrasound requires a larger-diameter transducer. In our study, we designed and manufactured a small ultrasound-based prototype catheter that can emit a lower frequency ultrasound (1.1 MHz). In order to evaluate the safety and efficacy of local low-frequency ultrasound-enhanced thrombolysis, a microbubble (MB) was introduced to augment thrombolysis effect of locally delivered low-intensity ultrasound. The results demonstrated that combination of ultrasound and MB realized higher clot lysis than urokinase-only treatment (17.0% ± 1.2% vs. 14.9% ± 2.7%) under optimal ultrasound settings of 1.1 MHz, 0.414 MPa, 4.89 W/cm2, 5% duty cycle and MB concentration of 60 μg/mL. When urokinase was added, the fibrinolysis accelerated by MB and ultrasound resulted in a further increased thrombolysis rate that was more than two times than that of urokinase alone (36.7% ± 5.5% vs. 14.9% ± 2.7%). However, a great quantity of ultrasound energy was required to achieve substantial clot lysis without MB, leading to the situation that temperature accumulated inside the clot became harmful. We suggest that MB-assisted local sonothrombolysis be considered as adjuvant therapy of thrombolytic agents.
14 August 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Based on the Fresnel half-wave band interference and laser engraving, a high frequency self-focusing piezoelectric composite ultrasound transducer was presented in this paper. The theoretical analysis was deduced based on the concept of constructive interference of acoustic waves and electromechanical response of piezoelectric composites. The calculated and simulation results showed that it combined the advantages of composite transducer and plate self-focusing transducer, and can achieve high electromechanical coupling coefficient (> 0.66), low acoustic impedance (~15 MRayl), high intensity and short focal length. Furthermore, a 30 MHz self-focusing piezoelectric composite transducer prototype was fabricated and tested. It is composed of 11 PZT and 10 epoxy annuluses. A UV engraving laser with line width of 10 lm was used to each the PZT to form the annuluses and the kerf among the annuluses was filled with epoxy. The measured center frequency, bandwidth and focal length was 27 MHz, 50.37% and 3.7 mm, respectively. A vertical wire phantom was imaged using fabricated transducer and contrast flat transducer, the images showed a significant improvement in lateral resolution over a range of 9 mm. Because this self-focusing piezoelectric composite transducer was based on the precise laser engraving systems, the fabrication process was accurate and controllable, which made it have good potential for medical imaging and industrial nondestructive testing applications.