Chen Yang

Mr. Chen Yang

University of Science and Technology of China
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Chen YangChen Yang
Chen Yang
XJXiaohua Jian
Xiaohua Jian
XZXinle Zhu
Xinle Zhu
JLJiabing Lv
Jiabing Lv
YJYang Jiao
Yang Jiao
YCYaoyao Cui
Yaoyao Cui
Photoacoustic (PA) imaging is a hybrid imaging technique that can provide both structural and functional information of biological tissues. Due to limited permissible laser energy deposited on tissues, highly sensitive PA imaging is required. Here, we developed a 20 MHz lead zirconium titanate (PZT) transducer (1.5 mm × 3 mm) with front-end amplifier circuits for local signal processing to achieve sensitivity enhanced PA imaging. The electrical and acoustic performance was characterized. Experiments on phantoms and chicken breast tissue were conducted to validate the imaging performance. The fabricated prototype shows a bandwidth of 63% and achieves a noise equivalent pressure (NEP) of 0.24 mPa/√Hz and a receiving sensitivity of 62.1 μV/Pa at 20 MHz without degradation of the bandwidth. PA imaging of wire phantoms demonstrates that the prototype is capable of improving the detection sensitivity by 10 dB compared with the traditional transducer without integrated amplifier. In addition, in vitro experiments on chicken breast tissue show that structures could be imaged with enhanced contrast using the prototype and the imaging depth range was improved by 1 mm. These results demonstrate that the transducer with an integrated front-end amplifier enables highly sensitive PA imaging with improved penetration depth. The proposed method holds the potential for visualization of deep tissue structures and enhanced detection of weak physiological changes.

14 August 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
XJXiaohua Jian
Xiaohua Jian
PLPengbo Liu
Pengbo Liu
ZLZhangjian Li
Zhangjian Li
JLJiabing Lv
Jiabing Lv
Chen YangChen Yang
Chen Yang
YCYaoyao Cui
Yaoyao Cui
Based on the Fresnel half-wave band interference and laser engraving, a high frequency self-focusing piezoelectric composite ultrasound transducer was presented in this paper. The theoretical analysis was deduced based on the concept of constructive interference of acoustic waves and electromechanical response of piezoelectric composites. The calculated and simulation results showed that it combined the advantages of composite transducer and plate self-focusing transducer, and can achieve high electromechanical coupling coefficient (> 0.66), low acoustic impedance (~15 MRayl), high intensity and short focal length. Furthermore, a 30 MHz self-focusing piezoelectric composite transducer prototype was fabricated and tested. It is composed of 11 PZT and 10 epoxy annuluses. A UV engraving laser with line width of 10 lm was used to each the PZT to form the annuluses and the kerf among the annuluses was filled with epoxy. The measured center frequency, bandwidth and focal length was 27 MHz, 50.37% and 3.7 mm, respectively. A vertical wire phantom was imaged using fabricated transducer and contrast flat transducer, the images showed a significant improvement in lateral resolution over a range of 9 mm. Because this self-focusing piezoelectric composite transducer was based on the precise laser engraving systems, the fabrication process was accurate and controllable, which made it have good potential for medical imaging and industrial nondestructive testing applications.

1 September 2019 in Microelectronic Engineering
Verified
Journal Article
Closed access
Chen YangChen Yang
Chen Yang
MLMujun Li
Mujun Li
JWJianping Wang
Jianping Wang
HYHuichun Ye
Huichun Ye
JQJinfeng Qiu
Jinfeng Qiu

20 January 2021 in Photonics
Verified
Journal Article
Open access
PDF file
Chen YangChen Yang
Chen Yang
YJYang Jiao
Yang Jiao
XJXiaohua Jian
Xiaohua Jian
YCYaoyao Cui
Yaoyao Cui
Optoacoustic tomography (OAT) is a hybrid biomedical imaging modality that usually employs a transducer array to detect laser-generated ultrasonic signals. The reconstructed image suffers low contrast and degraded resolution due to the limited bandwidth and the spatial directivity of the transducer element. Here, we introduce a modified image deconvolution method with a hybrid reweighted adaptive total variation tailored to improve the image quality of OAT. The effectiveness and the parameter dependency of the proposed method are verified on standard test images. The performance of the proposed method in OAT is then characterized on both simulated phantoms and in vivo mice experiments, which demonstrates that the modified deconvolution algorithm is able to restore the sharp edges and fine details in OAT simultaneously. The signal-to-noise ratios (SNRs) of the target structures in mouse liver and brain were improved by 4.90 and 12.69 dB, respectively. We also investigated the feasibility of using Fourier ring correlation (FRC) as an indicator of the image quality to monitor the deconvolution progress in OAT. Based on the experimental results, a practical guide for image deconvolution in OAT was summarized. We anticipate that the proposed method will be a promising post-processing tool to enhance the visualization of micro-structures in OAT.