Daniel Edelhoff

Prof. Dr. Daniel Edelhoff


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
JSJosef Schweiger
Josef Schweiger
DEDaniel Edelhoff
Daniel Edelhoff
JGJan-Frederik Güth
Jan-Frederik Güth
Popular media now often present 3D printing as a widely employed technology for the production of dental prostheses. This article aims to show, based on factual information, to what extent 3D printing can be used in dental laboratories and dental practices at present. It attempts to present a rational evaluation of todays´ applications of 3D printing technology in the context of dental restorations. In addition, the article discusses future perspectives and examines the ongoing viability of traditional dental laboratory services and manufacturing processes. It also shows which expertise is needed for the digital additive manufacturing of dental restorations.


4 September 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
TGTobias Graf
Tobias Graf
KEKurt-Jürgen Erdelt
Kurt-Jürgen Erdelt
JGJan-Frederik Güth
Jan-Frederik Güth
DEDaniel Edelhoff
Daniel Edelhoff
OSOliver Schubert
Oliver Schubert
JSJosef Schweiger
Josef Schweiger
The aim of this in vitro study is to investigate the bonding properties of a 3D-printable permanent composite material in comparison to milled composite materials. The tested materials are 3D-printed BEGO VarseoSmile Crown plus (VA1_ab, VA1_nt, VA2_ab, VA2_nt), Vita Enamic (EN1, EN2), and 3M Lava Ultimate (UL1, UL2) (N = 64; n = 8). For this purpose, all crowns are luted to polymer tooth stumps #46 (FDI) using dual-curing luting composite, strictly according to the manufacturer’s instructions. VA1_ab and VA2_ab are additionally airborne-particle abraded. 4 groups (VA2_ab, VA2_nt, EN2, UL2) are artificially aged (1,200,000 cycles, 50 N, 10,000 thermocycles), whereby no specimen has failed. All 64 specimens undergo pull-off testing until retention loss. The mean forces of retention-loss is 786.6 ± 137.6 N (VA1_nt, *), 988.6 ± 212.1 N (VA2_nt, *, Ɨ), 1223.8 ± 119.2 N (VA1_ab, Ɨ, ǂ), 1051.9 ± 107.2 N (VA2_ab, *, Ɨ), 1185.9 ± 211.8 N (EN1, Ɨ, ǂ), 1485.0 ± 198.2 N EN2, ǂ), 1533.8 ± 42.4 N (UL1, ǂ), and 1521.8 ± 343.4 N (UL2, ǂ) (one-way ANOVA (Scheffé method); p < 0.05; *, Ɨ, ǂ: group distribution). No characteristic failure modes can be detected. In conclusion, all of the pull-off forces reflect retention values that seem to be sufficiently high for clinical use. Additional airborne-particle abrasion of VA does not result in significantly better retention but can be recommended.

1 March 2016
Verified
Journal Article
Closed access
DEDaniel Edelhoff
Daniel Edelhoff
ALAnja Liebermann
Anja Liebermann
FBFlorian Beuer
Florian Beuer
MSMichael Stimmelmayr
Michael Stimmelmayr
JGJan-Frederik Güth
Jan-Frederik Güth

9 March 2016 in Materials
Verified
Journal Article
Open access
PDF file
CSChristine Schatz
Christine Schatz
MSMonika Strickstrock
Monika Strickstrock
MRMalgorzata Roos
Malgorzata Roos
DEDaniel Edelhoff
Daniel Edelhoff
MEMarlis Eichberger
Marlis Eichberger
Bogna StawarczykBogna Stawarczyk
Bogna Stawarczyk
The aim of this work was to evaluate the influence of specimen preparation and test method on the flexural strength results of monolithic zirconia. Different monolithic zirconia materials (Ceramill Zolid (Amann Girrbach, Koblach, Austria), Zenostar ZrTranslucent (Wieland Dental, Pforzheim, Germany), and DD Bio zx2 (Dental Direkt, Spenge, Germany)) were tested with three different methods: 3-point, 4-point, and biaxial flexural strength. Additionally, different specimen preparation methods were applied: either dry polishing before sintering or wet polishing after sintering. Each subgroup included 40 specimens. The surface roughness was assessed using scanning electron microscopy (SEM) and a profilometer whereas monoclinic phase transformation was investigated with X-ray diffraction. The data were analyzed using a three-way Analysis of Variance (ANOVA) with respect to the three factors: zirconia, specimen preparation, and test method. One-way ANOVA was conducted for the test method and zirconia factors within the combination of two other factors. A 2-parameter Weibull distribution assumption was applied to analyze the reliability under different testing conditions. In general, values measured using the 4-point test method presented the lowest flexural strength values. The flexural strength findings can be grouped in the following order: 4-point < 3-point < biaxial. Specimens prepared after sintering showed significantly higher flexural strength values than prepared before sintering. The Weibull moduli ranged from 5.1 to 16.5. Specimens polished before sintering showed higher surface roughness values than specimens polished after sintering. In contrast, no strong impact of the polishing procedures on the monoclinic surface layer was observed. No impact of zirconia material on flexural strength was found. The test method and the preparation method significantly influenced the flexural strength values.

1 April 2011 in The Journal of the American Dental Association
Verified
Journal Article
Closed access
DEDaniel Edelhoff
Daniel Edelhoff
OBOliver Brix
Oliver Brix