Xiaolin Chen

Dr. Xiaolin Chen

Computer Aided Engineering Lab., Washington State University, Vancouver, WA 98686, USA

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
AAArian Aghilinejad
Arian Aghilinejad
MAMohammad Aghaamoo
Mohammad Aghaamoo
XCXiaolin Chen
Xiaolin Chen
Deterministic lateral displacement (DLD), which takes advantage of the asymmetric bifurcation of laminar flow around the embedded microposts, has shown promising capabilities in separating cells and particles of different sizes. Growing interest in utilizing high-throughput DLD devices for practical applications, such as circulating tumor cell separation, necessitates employing higher flow rates in these devices, leading to operating in moderate to high Reynolds number (Re) regimes. Despite extensive research on DLD devices in the creeping regime, limited research has focused on the physics of flow, critical size of the device, and deformable cell behavior in DLD devices at moderate to high Re. In this study, the transport behavior of particles/cells is investigated in realistic high-throughput DLD devices with hundreds of microposts by utilizing multiphysics modeling. A practical formula is proposed for the prediction of the device critical size, which could serve as a design guideline for high-throughput DLD devices. Then, the complex hydrodynamic interactions between a deformable cell and DLD post arrays are investigated. A dimensionless index is utilized for comparing different post designs to quantify the cell–post interaction. It is shown that the separation performances in high-throughput devices are highly affected by Re as well as the micropost shapes. These findings can be utilized for the design and optimization of high-throughput DLD microfluidic devices.

27 March 2023 in Biotechnology Progress
Verified
Journal Article
Open access
SISadiqul Islam
Sadiqul Islam
XCXiaolin Chen
Xiaolin Chen
The efficient isolation of viable and intact circulating tumor cells (CTCs) from blood is critical for the genetic analysis of cancer cells, prediction of cancer progression, development of drugs, and evaluation of therapeutic treatments. While conventional cell separation devices utilize the size difference between CTCs and other blood cells, they fail to separate CTCs from white blood cells (WBCs) due to significant size overlap. To overcome this issue, we present a novel approach that combines curved contraction–expansion (CE) channels with dielectrophoresis (DEP) and inertial microfluidics to isolate CTCs from WBCs regardless of size overlap. This label‐free and continuous separation method utilizes dielectric properties and size variation of cells for the separation of CTCs from WBCs. The results demonstrate that the proposed hybrid microfluidic channel can effectively isolate A549 CTCs from WBCs regardless of their size with a throughput of 300 μL/min, achieving a high separation distance of 233.4 μm at an applied voltage of 50 Vp–p. The proposed method allows for the modification of cell migration characteristics by controlling the number of CE sections of the channel, applied voltage, applied frequency, and flow rate. With its unique features of a single‐stage separation, simple design, and tunability, the proposed method provides a promising alternative to the existing label‐free cell separation techniques and may have a wide range of applications in biomedicine.

28 September 2021 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
MRMehdi Rahmati
Mehdi Rahmati
XCXiaolin Chen
Xiaolin Chen

29 August 2018 in Theoretical and Computational Fluid Dynamics
Verified
Journal Article
Closed access
PDF file
XZXiaolong Zhang
Xiaolong Zhang
MHMohammad Abul Hashem
Mohammad Abul Hashem
XCXiaolin Chen
Xiaolin Chen
Hua TanHua Tan
Hua Tan

18 August 2017 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
XZXiaolong Zhang
Xiaolong Zhang
XCXiaolin Chen
Xiaolin Chen
Hua TanHua Tan
Hua Tan

23 April 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
EGEric Gioe
Eric Gioe
MUMohammed Raihan Uddin
Mohammed Raihan Uddin
JKJong-Hoon Kim
Jong-Hoon Kim
XCXiaolin Chen
Xiaolin Chen
Deterministic lateral displacement (DLD) is a microfluidic method for the continuous separation of particles based on their size. There is growing interest in using DLD for harvesting circulating tumor cells from blood for further assays due to its low cost and robustness. While DLD is a powerful tool and development of high-throughput DLD separation devices holds great promise in cancer diagnostics and therapeutics, much of the experimental data analysis in DLD research still relies on error-prone and time-consuming manual processes. There is a strong need to automate data analysis in microfluidic devices to reduce human errors and the manual processing time. In this work, a reliable particle detection method is developed as the basis for the DLD separation analysis. Python and its available packages are used for machine vision techniques, along with existing identification methods and machine learning models. Three machine learning techniques are implemented and compared in the determination of the DLD separation mode. The program provides a significant reduction in video analysis time in DLD separation, achieving an overall particle detection accuracy of 97.86% with an average computation time of 25.274 s.