Arian Aghilinejad

Arian Aghilinejad

Auto-generated profile, based on publicly available information

Arian Aghilinejad

Department of Medical Engineering, California Institute of Technology, Pasadena, California, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2019 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
MAMohammad Aghaamoo
Mohammad Aghaamoo
AAArian Aghilinejad
Arian Aghilinejad
XCXiaolin Chen
Xiaolin Chen
JXJie Xu
Jie Xu

18 May 2018 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
BDBrian M. Dincau
Brian M. Dincau
AAArian Aghilinejad
Arian Aghilinejad
THTaylor Hammersley
Taylor Hammersley
XCXiaolin Chen
Xiaolin Chen
JKJong-Hoon Kim
Jong-Hoon Kim

20 November 2017 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
AAArian Aghilinejad
Arian Aghilinejad
MAMohammad Aghaamoo
Mohammad Aghaamoo
XCXiaolin Chen
Xiaolin Chen
JXJie Xu
Jie Xu

1 May 2019 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
AAArian Aghilinejad
Arian Aghilinejad
MAMohammad Aghaamoo
Mohammad Aghaamoo
XCXiaolin Chen
Xiaolin Chen
Deterministic lateral displacement (DLD), which takes advantage of the asymmetric bifurcation of laminar flow around the embedded microposts, has shown promising capabilities in separating cells and particles of different sizes. Growing interest in utilizing high-throughput DLD devices for practical applications, such as circulating tumor cell separation, necessitates employing higher flow rates in these devices, leading to operating in moderate to high Reynolds number (Re) regimes. Despite extensive research on DLD devices in the creeping regime, limited research has focused on the physics of flow, critical size of the device, and deformable cell behavior in DLD devices at moderate to high Re. In this study, the transport behavior of particles/cells is investigated in realistic high-throughput DLD devices with hundreds of microposts by utilizing multiphysics modeling. A practical formula is proposed for the prediction of the device critical size, which could serve as a design guideline for high-throughput DLD devices. Then, the complex hydrodynamic interactions between a deformable cell and DLD post arrays are investigated. A dimensionless index is utilized for comparing different post designs to quantify the cell–post interaction. It is shown that the separation performances in high-throughput devices are highly affected by Re as well as the micropost shapes. These findings can be utilized for the design and optimization of high-throughput DLD microfluidic devices.

14 November 2018 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
BDBrian M. Dincau
Brian M. Dincau
AAArian Aghilinejad
Arian Aghilinejad
XCXiaolin Chen
Xiaolin Chen
SMSe Youn Moon
Se Youn Moon
JKJong-Hoon Kim
Jong-Hoon Kim

4 November 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RARashid Alavi
Rashid Alavi
AAArian Aghilinejad
Arian Aghilinejad
HWHeng Wei
Heng Wei
SNSoha Niroumandi
Soha Niroumandi
SWSeth Wieman
Seth Wieman
Niema PahlevanNiema Pahlevan
Niema Pahlevan
In-vitro models of the systemic circulation have gained a lot of interest for fundamental understanding of cardiovascular dynamics and for applied hemodynamic research. In this study, we introduce a physiologically accurate in-vitro hydraulic setup that models the hemodynamics of the coupled atrioventricular-aortic system. This unique experimental simulator has three major components: 1) an arterial system consisting of a human-scale artificial aorta along with the main branches, 2) an artificial left ventricle (LV) sac connected to a programmable piston-in-cylinder pump for simulating cardiac contraction and relaxation, and 3) an artificial left atrium (LA). The setup is designed in such a way that the basal LV is directly connected to the aortic root via an aortic valve, and to the LA via an artificial mitral valve. As a result, two-way hemodynamic couplings can be achieved for studying the effects that the LV, aorta, and LA have on each other. The collected pressure and flow measurements from this setup demonstrate a remarkable correspondence to clinical hemodynamics. We also investigate the physiological relevancies of isolated effects on cardiovascular hemodynamics of various major global parameters found in the circulatory system, including LV contractility, LV preload, heart rate, aortic compliance, and peripheral resistance. Subsequent control over such parameters ultimately captures physiological hemodynamic effects of LV systolic dysfunction, preload (cardiac) diseases, and afterload (arterial) diseases. The detailed design and fabrication of the proposed setup is also provided.