This paper examines a new study on the synergistic effect of magnetic nanoparticles and wormlike micelles (WLMs) on drag reduction. Fe3O4 magnetic nanoparticles (FE-NPs) are utilized to improve the performance of viscoelastic surfactant (VES) solutions used as fracturing fluids. The chemical composition and micromorphology of the FE-NPs were analyzed with FT-IR and an electron microscope. The stability and interaction of the WLM-particle system were studied by zeta potential and cryo-TEM measurements. More importantly, the influences of the temperature, FE-NP concentration, magnetic field intensity, and direction on the drag reduction rate of WLMs were systematically investigated in a circuit pipe flow system with an electromagnetic unit. The experimental results show that a suitable content of magnetic nanoparticles can enhance the settlement stability and temperature resistance of WLMs. A magnetic field along the flow direction of the fracturing fluid can improve the drag reduction performance of the magnetic WLM system. However, under a magnetic field perpendicular to the direction of fluid flow, an additional flow resistance is generated by the vertical chaining behavior of FE-NPs, which is unfavorable for the drag reduction performance of magnetic VES fracturing fluids. This study may shed light on the mechanism of the synergistic drag reduction effects of magnetic nanoparticles and wormlike micelles.
1 September 2021 in International Journal of Hydrogen Energy
Fe3O4@ZnO nanocomposites (NCs) were synthesized to improve the stability of the wormlike micelle (WLM) network structure of viscoelastic surfactant (VES) fracturing fluid and were characterized by Fourier transform infrared spectrometry (FT-IR), scanning electron microscopy (SEM), energy dispersive spectrometry (EDS), X-ray diffraction (XRD) and vibrating sample magnetometry (VSM). Then, an NC-enhanced viscoelastic surfactant solution as a fracturing fluid (NC-VES) was prepared, and its properties, including settlement stability, interactions between NCs and WLMs, proppant-transporting performance and gel-breaking properties, were systematically studied. More importantly, the influences of the NC concentration, shear rate, temperature and pH level on the stability of NC-VES were systematically investigated. The experimental results show that the NC-VES with a suitable content of NCs (0.1 wt.%) shows superior stability at 95 °C or at a high shear rate. Meanwhile, the NC-VES has an acceptable wide pH stability range of 6–9. In addition, the NC-VES possesses good sand-carrying performance and gel-breaking properties, while the NCs can be easily separated and recycled by applying a magnetic field. The temperature-resistant, stable and environmentally friendly fracturing fluid opens an opportunity for the future hydraulic fracturing of unconventional reservoirs.
HPAM/PEI gel is a promising material for conformance control in hydrocarbon reservoirs. However, its use in low-permeability reservoirs is limited by the high polymer concentrations present. In this study, the gelation performance of an HPAM/PEI system with HPAM < 2.0 wt.% was systematically investigated. The gelation time for HPAM concentrations ranging from 0.4 to 2.0 wt.% varied from less than 1 h to 23 days, with the highest gel strength identified as grade H. The hydrodynamic radius manifested the primary effect of HPAM on the gelation performance. Branched PEI provided superior gelation performance over linear PEI, and the gelation performance was only affected when the molecular weight of the PEI varied significantly. The optimal number ratio of the PEI-provided imine groups and the HPAM-provided carboxylic acid functional groups was approximately 1.6:1~5:1. Regarding the reservoir conditions, the temperature had a crucial effect on the hydrodynamic radius of HPAM. Salts delayed the gelation process, and the order of ionic influence was Ca2+ > Na+ > K+. The pH controlled the crosslinking reaction, primarily due to the protonation degree of PEI and the hydrolysis degree of HPAM, and the most suitable pH was approximately 10.5. Plugging experiments based on a through-type fracture showed that multi-slug plugging could significantly improve the plugging performance of the system, being favorable for its application in fractured low-permeability reservoirs.