Pedro Samaniego

Mr. Pedro Samaniego


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2021 in Metals
Verified
Journal Article
Open access
PDF file
JJJesus Jáquez-Muñoz
Jesus Jáquez-Muñoz
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
ALAlejandro Lira-Martinez
Alejandro Lira-Martinez
Patricia Zambrano-RobledoPatricia Zambrano-Robledo
Patricia Zambrano-Robledo
EMErick Maldonado-Bandala
Erick Maldonado-Bandala
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
Titanium alloys are used in different industries like biomedical, aerospace, aeronautic, chemical, and naval. Those industries have high requirements with few damage tolerances. Therefore, they are necessary to use materials that present fatigue, mechanical, and corrosion resistance. Although Ti-alloys are material with high performance, they are exposed to corrosion in marine and industrial environments. This research shows the corrosion behavior of three titanium alloys, specifically Ti CP2, Ti-6Al-2Sn-4Zr-2Mo, and Ti-6Al-4V. Alloys were exposed on two electrolytes to a 3.5 wt % H2SO4 and NaCl solutions at room temperature using cyclic potentiodynamic polarization (CPP) and electrochemical noise (EN) according to ASTM G61 and ASTM G199 standards. CPP technique was employed to obtain electrochemical parameters as the passivation range (PR), corrosion type, passive layer persistence, corrosion potential (Ecorr), and corrosion rate. EN was analyzed by power spectral density (PSD) in voltage. Results obtained revealed pseudopassivation in CPP and PSD exposed on NaCl for Ti-6Al-2Sn-4Zr-2Mo, indicating instability and corrosion rate lower. However, Ti-6Al-4V presented the highest corrosion rate in both electrolytes. Ti-6Al-2Sn-4Zr-2Mo revealed pseudopassivation in CPP and PSD in NaCl, indicating a passive layer unstable. However, the corrosion rate was lower in both solutions.

13 April 2022 in Metals
Verified
Journal Article
Open access
PDF file
PSPedro Samaniego
Pedro Samaniego
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
José Guadalupe ChacónJosé Guadalupe Chacón
José Guadalupe Chacón
EMErick Maldonado-Bandala
Erick Maldonado-Bandala
DNDemetrio Nieves-Mendoza
Demetrio Nieves-Mendoza
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
Custom 450 stainless steel and AM 350 stainless steel are both precipitation hardening stainless steels, which are widely used in a variety of aerospace applications. The former steel exhibits very good corrosion resistance with moderate strength, whereas the latter is used for applications requiring high strength along with corrosion resistance. In this study, the corrosion behavior of CUSTOM 450 and AM 350 stainless steels passivated in (a) citric acid and (b) nitric acid solutions for 50 and 75 min at 49 and 70 °C, and subsequently exposed in 5 wt. % NaCl and 1 wt. % H2SO4 solutions are investigated. Two electrochemical techniques were used: electrochemical noise (EN) and electrochemical impedance spectroscopy (EIS) according to ASTM G199-09 and ASTM G106-13, respectively. The results indicated that passivation in nitric acid made the surface prone to localized corrosion. Statistical and PSD values showed a tendency toward pitting corrosion. On the whole, passivated CUSTOM 450 stainless steel showed the best corrosion behavior in both, NaCl and H2SO4 test solutions.

21 October 2021 in Coatings
Verified
Journal Article
Open access
PDF file
PSPedro Samaniego
Pedro Samaniego
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
EMErick Maldonado-Bandala
Erick Maldonado-Bandala
José Cabral MiramontesJosé Cabral Miramontes
José Cabral Miramontes
DNDemetrio Nieves-Mendoza
Demetrio Nieves-Mendoza
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
The aim of this work was to evaluate the corrosion behavior of the AA2055 Aluminum-lithium alloy anodized in a sulfuric acid (H2SO4) bath, varying the current density of 0.19 and 1 A·cm−2 and why the sealing solution was water (H2O) and sodium dichromate (Na2Cr2O7). Anodized samples were exposed to a 10 vol.% H2SO4 solution and the electrochemical technique used was electrochemical impedance spectroscopy. Scanning electron microscopy and X-ray photoelectron spectroscopy were employed to characterization of the anodizing layer, determinate morphology and thickness of coatings. The Na2Cr2O7 sealing solution tends to increase the charge transfer resistance and produces a more homogeneous and compact passive oxide layer, and imparts a corrosion inhibition protection to the AA2055. SEM observations indicated that the morphology and thickness of the anodic films formed on AA2055 aluminum-lithium alloy anodized have the best results for both current densities.

17 June 2022 in Metals
Verified
Journal Article
Open access
PDF file
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
PSPedro Samaniego
Pedro Samaniego
EMErick Maldonado-Bandala
Erick Maldonado-Bandala
DNDemetrio Nieves-Mendoza
Demetrio Nieves-Mendoza
FOFrancisco Javier Olguin-Coca
Francisco Javier Olguin-Coca
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
This research aimed to conduct a passive layer state study on martensitic and semi-austenitic precipitation hardening stainless steels (PHSS) passivated in citric acid and nitric acid baths at 49 and 70 °C for 50 and 75 min and subsequently exposed in 5 wt.% NaCl and 1 wt.% H2SO4 solutions. Corrosion behavior of the passivated material was observed by using potentiodynamic polarization (PP) according to the ASTM G5-11 standard. The microstructural analysis was performed by optical microscopy and scanning electron microscopy (SEM), while the passivated layer was characterized by X-ray photoelectron spectroscopy (XPS). The results indicated that the semi-austenitic-NA-50 min-70 °C sample showed the best corrosion resistance behavior in both solutions. The XPS characterization confirmed that the martensitic and semi-austenitic surface film presented a mixture of chemical compounds, such as Cr2O3 and Fe(OH)O, respectively.