Citlalli Gaona-Tiburcio

Dr. Citlalli Gaona-Tiburcio

Universidad Autónoma de Nuevo León, San Nicolás de los Garza, Nuevo León, Mexico
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Construction and Building Materials
Verified
Journal Article
Closed access
VJV.G. Jiménez-Quero
V.G. Jiménez-Quero
FMFrank Manuel León Martínez
Frank Manuel León Martínez
PMP. Montes-García
P. Montes-García
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
JCJ.G. Chacón-Nava
J.G. Chacón-Nava

3 December 2019 in Materials
Verified
Journal Article
Open access
PDF file
Miguel  Angel Baltazar-ZamoraMiguel Angel Baltazar-Zamora
Miguel Angel Baltazar-Zamora
David M. BastidasDavid M. Bastidas
David M. Bastidas
GSGriselda Santiago-Hurtado
Griselda Santiago-Hurtado
JMJose Manuel Mendoza-Rangel
Jose Manuel Mendoza-Rangel
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
The use of supplementary cementitious materials such as fly ash, slag, and silica fume improve reinforced concrete corrosion performance, while decreasing cost and reducing environmental impact compared to ordinary Portland cement. In this study, the corrosion behavior of AISI 1018 carbon steel (CS) and AISI 304 stainless steel (SS) reinforcements was studied for 365 days. Three different concrete mixtures were tested: 100% CPC (composite Portland cement), 80% CPC and 20% silica fume (SF), and 80% CPC and 20% fly ash (FA). The concrete mixtures were designed according to the ACI 211.1 standard. The reinforced concrete specimens were immersed in a 3.5 wt.% NaCl test solution to simulate a marine environment. Corrosion monitoring was evaluated using the corrosion potential (Ecorr) according to ASTM C876 and the linear polarization resistance (LPR) according to ASTM G59. The results show that AISI 304 SS reinforcements yielded the best corrosion behavior, with Ecorr values mainly pertaining to the region of 10% probability of corrosion, and corrosion current density (icorr) values indicating passivity after 105 days of experimentation and low probability of corrosion for the remainder of the test period.

1 March 2022 in Coatings
Verified
Journal Article
Open access
PDF file
JJJesus Jáquez-Muñoz
Jesus Jáquez-Muñoz
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
José Guadalupe ChacónJosé Guadalupe Chacón
José Guadalupe Chacón
José Cabral MiramontesJosé Cabral Miramontes
José Cabral Miramontes
DNDemetrio Nieves-Mendoza
Demetrio Nieves-Mendoza
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
Titanium and its alloys have superior electrochemical properties compared to other alloy systems due to the formation of a protective TiO2 film on metal surfaces. The ability to generate the protective oxide layer will depend upon the type of alloy to be used. The aim of this work was to characterize the electrochemical corrosion behavior of titanium Ti-CP2 and alloys Ti-6Al-2Sn-4Zr-2Mo, Ti-6Al-4V, and Ti Beta-C. Samples were anodized in 1 M H2SO4 and H3PO4 solutions with a current density of 0.025 A/cm2. Electrochemical tests on anodized alloys were carried out using a three-electrode cell and exposed in two electrolytes, i.e., 3.5 wt % NaCl and 3.5 wt % H2SO4 solutions at room temperature. Scanning electron microscopy (SEM) was used to observe the morphology of anodized surfaces. The electrochemical techniques used were cyclic potentiodynamic polarization (CPP) and electrochemical noise (EN), based on the ASTM-G61 and G199 standards. Regarding EN, two methods of data analysis were used: the frequency domain (power spectral density, PSD) and time-frequency domain (discrete wavelet transform). For non-anodized alloys, the results by CCP and EN indicate icorr values of ×10−6 A/cm2. However, under anodizing conditions, the icorr values vary from ×10−7 to ×10−9 A/cm2. The PSD Ψ0 values are higher for non-anodized alloys, while in anodized conditions, the values range from −138/−122 dBi (A2·Hz−1)1/2 to −131/−180 dBi (A2·Hz−1)1/2. Furthermore, the results indicated that the alloys anodized in the H3PO4 bath showed an electrochemical behavior that can be associated with a more homogeneous passive layer when exposed to the 3.5 wt % NaCl electrolyte. Alloys containing more beta-phase stabilizers formed a less homogeneous anodized layer. These alloys are widely used in aeronautical applications; thus, it is essential that these alloys have excellent corrosion performance in chloride and acid rain environments.

7 January 2021 in Metals
Verified
Journal Article
Open access
PDF file
JJJesus Jáquez-Muñoz
Jesus Jáquez-Muñoz
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
José Cabral MiramontesJosé Cabral Miramontes
José Cabral Miramontes
DNDemetrio Nieves-Mendoza
Demetrio Nieves-Mendoza
EMErick Maldonado-Bandala
Erick Maldonado-Bandala
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
Titanium alloys have been used in aerospace, aeronautic, automotive, biomedical, structural, and other applications because titanium alloys have less density than materials like steel and support higher stress than Al-alloys. However, components made of titanium alloys are exposed to corrosive environments, the most common being industrial and marine atmospheres. This research shows the corrosion behavior of three titanium alloys, specifically Ti-CP2, Ti-6Al-2Sn-4Zr-2Mo, and Ti-6Al-4V with α, near α, and α + β alloys phases. Alloys were exposed in two electrolytes to a 3.5 wt. % H2SO4 and NaCl solution at room temperature, and their electrochemical behavior was studied by electrochemical noise technique (EN) according to ASTM ASTM-G199 standard. EN signal was filtered by three different methods, and the polynomial method was employed to obtain Rn, kurtosis, skew, and the potential spectral density analysis (PSD). The wavelets method was used, from which energy dispersion plots were obtained. The last method was Hilbert–Huang Transform (HHT), where Hilbert Spectra were analyzed. Results indicated that Rn compared with PSD showed that Ti-6Al-2Sn-4Zr-2Mo presented less dissolution in both electrolytes. Statistical methods showed that the passive layer created on Ti alloys’ surfaces is unstable; this condition is notable for Ti-6Al-2Sn-4Zr-2Mo in NaCl solution.

1 May 2019 in International Journal of Electrochemical Science
Verified
Journal Article
Open access
José Cabral MiramontesJosé Cabral Miramontes
José Cabral Miramontes
DBD.M. Bastidas
D.M. Bastidas
MBM.A. Baltazar
M.A. Baltazar
Patricia Zambrano-RobledoPatricia Zambrano-Robledo
Patricia Zambrano-Robledo
JBJ.M. Bastidas
J.M. Bastidas
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio

24 April 2023 in Metals
Verified
Journal Article
Open access
PDF file
Jose Miguel Villegas TovarJose Miguel Villegas Tovar
Jose Miguel Villegas Tovar
Citlalli Gaona-TiburcioCitlalli Gaona-Tiburcio
Citlalli Gaona-Tiburcio
MLMaria Del Refugio Lara-Banda
Maria Del Refugio Lara-Banda
EMErick Maldonado-Bandala
Erick Maldonado-Bandala
Miguel  Angel Baltazar-ZamoraMiguel Angel Baltazar-Zamora
Miguel Angel Baltazar-Zamora
Facundo Almeraya-CalderónFacundo Almeraya-Calderón
Facundo Almeraya-Calderón
Precipitation-hardening (PH) stainless steels (SS) are widely used in various aerospace applications. These steels exhibit good mechanical and corrosion resistance. The electrochemical behavior of 15-5PH, 17-4PH, Custom450 and AM 350 stainless steels passivated with citric and nitric acid baths for 60 and 90 min at 25 and 49 °C were evaluated in 5 wt.% sodium chloride (NaCl) and 1 wt.% sulfuric acid (H2SO4) solutions. The electrochemical behavior was studied with potentiodynamic polarization curves (PPC) according to the ASTM G5-13 standard. The results indicated that there are two characteristic mechanisms that are present in the potentiodynamic polarization curves. When the PHSS is immersed in an H2SO4 solution, there is a secondary passivation, and in the NaCl solution, there is a pseudo-passivation (not stable passivation film). The current densities in the NaCl solution were between 10−4 and 10−5 mA/cm2, while those of H2SO4 were recorded around 10−2 and 10−3 mA/cm2. Citric acid does work as a passivating solution, and in some cases, the corrosion resistance of the stainless steel was comparable to that of nitric acid.