In the present study, the determination of histidine (HIS) by an on-line flow method based on the concept of zone fluidics is reported. HIS reacts fast with o-phthalaldehyde at a mildly basic medium (pH 7.5) and in the absence of additional nucleophilic compounds to yield a highly fluorescent derivative (λex/λem = 360/440 nm). The flow procedure was optimized and validated, paying special attention to its selectivity and sensitivity. The LOD was 31 nmol·L−1, while the within-day and day-to-day precisions were better than 1.0% and 5.0%, respectively (n = 6). Random urine samples from adult volunteers (n = 7) were successfully analyzed without matrix effect (<1%). Endogenous HIS content ranged between 116 and 1527 μmol·L−1 with percentage recoveries in the range of 87.6%–95.4%.
A novel, direct and simple colorimetric method employing μicroanalytical paper-based devices (μ-PADs) for the selective determination of bismuth is described. The suggested method exploits the colorimetric variation of bismuth after its rapid reaction with methyl thymol blue (MTB) in an acidic medium (pH ranging between 0.7 and 3.0), modified with nitric acid, on the surface of a paper device at room temperature. The devices are low cost, composed of chromatographic paper and wax barriers and the analytical protocol is easily applicable with minimal technical expertise and without the need for experimental apparatus. The user must add a test sample and read the color intensity of the colored Bi(III)–MTB complex formed at the sensing area using a simple imaging device such as a flatbed scanner. Various chemical variables, such as HNO3 and MTB concentration, reaction time, ionic strength, detection zone size and photo-capture detector are optimized. A study of interfering ions such as K+, Na+, Ca2+, Mg2+, Cl−, SO42− and HCO3− was also conducted. The stability of the paper devices is also studied in different maintenance conditions with particularly satisfactory results, rendering the method suitable for field analysis. The detection limits are as low as 3.0 mg L−1 with very satisfactory precision, ranging from 4.0% (intra-day) to 5.5% (inter-day). Natural water samples are successfully analyzed, and bismuth percentage recoveries were calculated in the range of 82.8 to 115.4%.
In this study, the development, validation, and application of a new liquid chromatography post-column derivatization method for the determination of Colistin in human urine samples is demonstrated. Separation of Colistin was performed using a core–shell C18 analytical column in an alkaline medium in order (i) to be compatible with the o-phthalaldehyde-based post-column derivatization reaction and (ii) to obtain better retention of the analyte. The Colistin derivative was detected spectrofluorometrically (λext/λem = 340/460 nm) after post-column derivatization with o-phthalaldehyde and N-acetyl cysteine. The post-column derivatization parameters were optimized using the Box–Behnken experimental design, and the method was validated using the total error concept. The β-expectation tolerance intervals did not exceed the acceptance criteria of ±15%, meaning that 95% of future results would be included in the defined bias limits. The limit of detection of the method was adequate corresponding to 100 nmol·L−1. The mean analytical bias (expressed as relative error) in the spiking levels was suitable, being in the range of −2.8 to +2.5% for both compounds with the percentage relative standard deviation lower than 3.4% in all cases. The proposed analytical method was satisfactorily applied to the analysis of the drug in human urine samples.