George Tsogkas

Dr. George Tsogkas

Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MTMaria Tarara
Maria Tarara
Paraskevas TzanavarasParaskevas Tzanavaras
Paraskevas Tzanavaras
George TsogkasGeorge Tsogkas
George Tsogkas
A novel, rapid, and facile method for the colorimetric determination of calcium using micro-analytical paper-based devices (μ-PADs) was developed. The proposed analytical method utilizes the color differences developing, after the addition of calcium, on the surface of the devices because of the complexation reaction of calcium with Methylthymol Blue (MTB) at room temperature, in alkaline pH. The devices were manufactured with chromatographic paper, using wax barriers, and the analytical protocol was easily implemented without the need of any experimental apparatus except for a simple imaging device. The user must regulate the pH, add the solutions on the paper, and measure the color intensity of the formed Ca(II)–MTB complex with a flatbed scanner. The experimental conditions for optimum color development, the possible interfering substances, and the reliability of the paper devices in different preserving conditions were optimized, with satisfactory results. The method exhibited acceptable detection limits (2.9 mg L−1) with sufficiently good precision, which varied from 4.2% (intra-day) to 6.4% (inter-day). Saliva samples from healthy volunteers were successfully analyzed, and the calcium levels were calculated in the range of 30.71 to 84.15 mg L−1.

28 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
VTVasiliki C. Tsaftari
Vasiliki C. Tsaftari
MTMaria Tarara
Maria Tarara
Paraskevas TzanavarasParaskevas Tzanavaras
Paraskevas Tzanavaras
George TsogkasGeorge Tsogkas
George Tsogkas
A simple, equipment-free, direct fluorometric method, employing paper-based analytical devices (PADs) as sensors, for the selective determination of quinine (QN) is described herein. The suggested analytical method exploits the fluorescence emission of QN without any chemical reaction after the appropriate pH adjustment with nitric acid, at room temperature, on the surface of a paper device with the application of a UV lamp at 365 nm. The devices crafted had a low cost and were manufactured with chromatographic paper and wax barriers, and the analytical protocol followed was extremely easy for the analyst and required no laboratory instrumentation. According to the methodology, the user must place the sample on the detection area of the paper and read with a smartphone the fluorescence emitted by the QN molecules. Many chemical parameters were optimized, and a study of interfering ions present in soft drink samples was carried out. Additionally, the chemical stability of these paper devices was considered in various maintenance conditions with good results. The detection limit calculated as 3.3 S/N was 3.6 mg L−1, and the precision of the method was satisfactory, being from 3.1% (intra-day) to 8.8% (inter-day). Soft drink samples were successfully analyzed and compared with a fluorescence method.

8 July 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
PBPanagiotis A. Bizirtsakis
Panagiotis A. Bizirtsakis
MTMaria Tarara
Maria Tarara
Apostolia TsiasiotiApostolia Tsiasioti
Apostolia Tsiasioti
Paraskevas TzanavarasParaskevas Tzanavaras
Paraskevas Tzanavaras
George TsogkasGeorge Tsogkas
George Tsogkas
A novel, direct and simple colorimetric method employing μicroanalytical paper-based devices (μ-PADs) for the selective determination of bismuth is described. The suggested method exploits the colorimetric variation of bismuth after its rapid reaction with methyl thymol blue (MTB) in an acidic medium (pH ranging between 0.7 and 3.0), modified with nitric acid, on the surface of a paper device at room temperature. The devices are low cost, composed of chromatographic paper and wax barriers and the analytical protocol is easily applicable with minimal technical expertise and without the need for experimental apparatus. The user must add a test sample and read the color intensity of the colored Bi(III)–MTB complex formed at the sensing area using a simple imaging device such as a flatbed scanner. Various chemical variables, such as HNO3 and MTB concentration, reaction time, ionic strength, detection zone size and photo-capture detector are optimized. A study of interfering ions such as K+, Na+, Ca2+, Mg2+, Cl−, SO42− and HCO3− was also conducted. The stability of the paper devices is also studied in different maintenance conditions with particularly satisfactory results, rendering the method suitable for field analysis. The detection limits are as low as 3.0 mg L−1 with very satisfactory precision, ranging from 4.0% (intra-day) to 5.5% (inter-day). Natural water samples are successfully analyzed, and bismuth percentage recoveries were calculated in the range of 82.8 to 115.4%.

11 June 2022 in Talanta
Verified
Journal Article
Closed access
MTMaria Tarara
Maria Tarara
ATApostolia Tsiasioti
Apostolia Tsiasioti
Paraskevas TzanavarasParaskevas Tzanavaras
Paraskevas Tzanavaras
George TsogkasGeorge Tsogkas
George Tsogkas

8 April 2022 in Talanta
Verified
Journal Article
Closed access
EAE.A. Akrivi
E.A. Akrivi
AVA.G. Vlessidis
A.G. Vlessidis
NKN.K. Kourkoumelis
N.K. Kourkoumelis
Dimosthenis L. GiokasDimosthenis L. Giokas
Dimosthenis L. Giokas
George TsogkasGeorge Tsogkas
George Tsogkas

17 June 2023 in Molecules
Verified
Journal Article
Open access
PDF file
AGArgyro Gkouliamtzi
Argyro Gkouliamtzi
VTVasiliki C. Tsaftari
Vasiliki C. Tsaftari
MTMaria Tarara
Maria Tarara
George TsogkasGeorge Tsogkas
George Tsogkas
This study reports a new approach for the determination of copper ions in water samples that exploits the complexation reaction with diethyldithiocarbamate (DDTC) and uses widely available imaging devices (i.e., flatbed scanners or smartphones) as detectors. Specifically, the proposed approach is based on the ability of DDTC to bind to copper ions and form a stable Cu-DDTC complex with a distinctive yellow color detected with the camera of a smartphone in a 96-well plate. The color intensity of the formed complex is linearly proportional to the concentration of copper ions, resulting in its accurate colorimetric determination. The proposed analytical procedure for the determination of Cu2+ was easy to perform, rapid, and applicable with inexpensive and commercially available materials and reagents. Many parameters related to such an analytical determination were optimized, and a study of interfering ions present in the water samples was also carried out. Additionally, even low copper levels could be noticed by the naked eye. The assay performed was successfully applied to the determination of Cu2+ in river, tap, and bottled water samples with detection limits as low as 1.4 µM, good recoveries (89.0–109.6%), adequate reproducibility (0.6–6.1%), and high selectivity over other ions present in the water samples.