Hugh Byrd

Prof. Hugh Byrd


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2016 in Sustainability
Verified
Journal Article
Open access
PDF file
HBHugh Byrd
Hugh Byrd
Eziaku Onyeizu RasheedEziaku Onyeizu Rasheed
Eziaku Onyeizu Rasheed
In this paper we challenge the notion that “green” buildings can achieve greater productivity than buildings that are not accredited as “green”. For nearly two decades, research has produced apparent evidence which indicates that the design of a “green” building can enhance the productivity of its occupants. This relationship between building design and productivity is claimed to be achieved through compliance with internal environmental quality (IEQ) criteria of Green rating tools. This paper reviews methods of measuring productivity and the appropriateness of the metrics used for measuring IEQ in office environments. This review is supported by the results of a survey of office building users which identifies social factors to be significantly more important than environmental factors in trying to correlate productivity and IEQ. It also presents the findings of observations that were discretely carried out on user-response in green buildings. These findings demonstrate that, despite a building’s compliance with IEQ criteria, occupants still resort to exceptional measures to alter their working environment in a bid to achieve comfort. The work has been carried out on “green” buildings in New Zealand. These buildings are rated based on the NZ “Green Star” system which has adopted the Australian “green star” system with its roots in BREEAM. Despite this, the results of this research are applicable to many other “green” rating systems. The paper concludes that methods of measuring productivity are flawed, that IEQ criteria for building design is unrepresentative of how occupants perceive the environment and that this can lead to an architecture that has few of the inherent characteristics of good environmental design.

30 October 2018 in Architectural Science Review
Verified
Journal Article
Open access
EAEhsan Ahmadian
Ehsan Ahmadian
HBHugh Byrd
Hugh Byrd
BSBehzad Sodagar
Behzad Sodagar
SMSteve Matthewman
Steve Matthewman
CKChristine Kenney
Christine Kenney
GMGlen Mills
Glen Mills
This paper reviews the historical research that has led to widespread policies on compact urban form, in particular, residential development, and collates evidence that demonstrates that dispersed urban form may be more energy efficient than compact form. This is counterintuitive but is supported by both challenging the conventional modelling of energy use of buildings as well as case studies with empirical evidence. The conclusion is that policies on urban form should be driven not by existing technologies but by the disruptive technologies of the future. The increased use in distributed energy generation in urban areas (generally roof-mounted photovoltaics), the growth in ownership of electric vehicles and the potential introduction of smart and micro-grids and the possibility of virtual power plants is changing the impact that energy has on built form and conflicts with current policies for denser, contained and compact development.

26 June 2012 in Architectural Science Review
Verified
Journal Article
Closed access
HBHugh Byrd
Hugh Byrd
This article presents the findings of research carried out on user response, from external evidence, in highly glazed office buildings and analyses the impact of this on predicting the environmental performance, productivity and energy consumption of office buildings. With high proportions of glazing, there is a significant difference between the theory and actual performance of a building envelope, in particular because of user preferences. Excessive glazing increases the probability of blinds being operated to reduce the impact of glare or direct sunlight. This significantly reduces the amount of daylight while only marginally reducing excessive heat gains. In the case of buildings in this research, it was found that blinds were extensively used and that artificial lighting was also used to supplement the loss of daylight, even on bright days. The additional energy used for both cooling and artificial lighting results in high proportions of glazing being responsible for significantly greater energy consumption than predicted and a potential loss in productivity.

1 October 2013 in Energy Policy
Verified
Journal Article
Closed access
HBHugh Byrd
Hugh Byrd
AHAnna Ho
Anna Ho
BSBasil Sharp
Basil Sharp
NNNirmal-Kumar C. Nair
Nirmal-Kumar C. Nair

26 May 2017 in Sustainability
Verified
Journal Article
Open access
PDF file
Eziaku Onyeizu RasheedEziaku Onyeizu Rasheed
Eziaku Onyeizu Rasheed
HBHugh Byrd
Hugh Byrd
BMBlair Money
Blair Money
JMJasper Mbachu
Jasper Mbachu
Egbelakin TemitopeEgbelakin Temitope
Egbelakin Temitope
In this paper, we investigated the reason(s) why natural ventilation is not as popular as air-conditioned or mixed-mode ventilation systems in Green-rated office buildings in New Zealand. To achieve this, we had three objectives. Firstly, we reviewed the Green Star criteria for thermal comfort in office buildings to ascertain which ventilation system the NZ Green Star rating tool promotes. Secondly, we ascertained the perception of occupants in office buildings regarding thermal comfort. This was followed by an interview with building experts regarding factors that affect the use of natural ventilation in New Zealand offices. The findings showed that the NZ Green Star thermal comfort criteria encourage the use of mechanical ventilation over natural ventilation which results in designers opting for air conditioning systems in office designs. We observed that occupants of naturally ventilated spaces were least satisfied with the thermal comfort of their offices when compared with occupants of mixed-mode and air-conditioned offices. This study fulfils the need to encourage the use of natural ventilation in office environments by designers and building owners. Further study on other aspects of the indoor environment quality that is related to naturally ventilated systems such as lighting and noise is required in a bid to ascertain its viability in office environments.

1 January 2011 in Procedia Engineering
Verified
Journal Article
Open access
HBHugh Byrd
Hugh Byrd
PLPaola Leardini
Paola Leardini
If the mission of ‘green’ rating tools is to accelerate the transformation of the global built environment towards sustainability then a high priority must be placed on the energy consumed by buildings since energy supplies from various sources are depleting. This paper examines the apparent anomaly that almost all designs of ‘green’ office developments in New Zealand have high proportions of unshaded glazing. They are sealed, lightweight, airconditioned buildings that are dependent on an uninterrupted supply of electricity in order to remain habitable. From an architectural science point of view, these characteristics are not normally associated with sustainability. The paper will investigate the drivers behind the highly glazed buildings recently realized in New Zealand, including those components of ‘green’ rating tools that favour this building typ