Eslam Taha

Mr. Eslam Taha

king Abdelaziz university
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2018 in Australasian Physics & Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
ETEslam Taha
Eslam Taha
FDFathi Djouider
Fathi Djouider
EBEssam Banoqitah
Essam Banoqitah

1 March 2019 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
ETEslam Taha
Eslam Taha
FDFathi Djouider
Fathi Djouider
EBEssam Banoqitah
Essam Banoqitah

1 March 2021 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
FAFouad Abolaban
Fouad Abolaban
MAMohammed A Alawi
Mohammed A Alawi
ETEslam Taha
Eslam Taha
EEEzzat Elmoujarkach
Ezzat Elmoujarkach
EBEssam Banoqitah
Essam Banoqitah
ANAndrew Nisbet
Andrew Nisbet
The aim of this study is to characterise the neutron flux generated directly behind targets used in medical cyclotrons. The characterisation process aims at determining the feasibility of using the generated neutrons for research purposes in neutron activation analysis. The study was performed by activating gold foils placed directly behind the cyclotron targets. The thermal and epithermal neutron flux were found to be 4.5E+05 ± 8.78E+04 neutrons cm−2 s−1 and 2.13E+06 ± 8.59E+04 neutrons cm−2 s−1, respectively. The flux value is the same order of magnitude listed in the manual produced by the cyclotron manufacturer. The results are encouraging and show high potential for using the cyclotron facility as a thermal neutron source for research purposes. However, it is important radiation protection procedures be followed to ensure the safety of researchers due to the high gamma dose rate measured directly behind the target at 2.46 Sv/h using an OSL chip during the beam on time.

1 January 2020 in Journal of Radiation Research and Applied Sciences
Verified
Journal Article
Open access
FAFouad Abolaban
Fouad Abolaban
ETEslam Taha
Eslam Taha
The purpose of this study is to validate GATE 8.1 Radiotherapy Monte Carlo (MC) simulation of a 6 MV Elekta Versa-HD linear accelerator at King Abdulaziz University Hospital (KAUH). The simulation data using GATE 8.1 was benchmarked against measured data at KAUH. The simulation comprises treatment head, Multi-Leaf Collimators (MLCs), and homogeneous water phantom, whereas the measured data was performed using MP3 phantom and PTW 31,010, 0.125 cm3 Semiflex Chamber. Dose depth distribution and dose profiles were carried out at three different field sizes 10x10, 20x20, and 30 × 30 cm2. The calculated TPR20,10 for the simulated data was found to be 0.658, 1.1% less than the measured TPR20,10 which was found to be 0.666. The obtained results indicate good agreement between the simulated and measured data, where Gamma Index 3%/3 mm criteria reached values of 97% and 90% for relative dose and dose profiles, respectively.

26 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FAFouad Abolaban
Fouad Abolaban
ETEslam Taha
Eslam Taha
AAAbdulsalam Alhawsawi
Abdulsalam Alhawsawi
FDFathi Djouider
Fathi Djouider
EBEssam Banoqitah
Essam Banoqitah
ANAndrew Nisbet
Andrew Nisbet
High atomic number nanoparticles are of increasing interest in radiotherapy due to their significant positive impact on the local dose applied to the treatment site. In this work, three types of metal nanoparticles were utilized to investigate their dose enhancement based on the GATE Monte Carlo simulation tool. Gold, gadolinium, and silver were implanted at three different concentrations to a 1 cm radius sphere to mimic a cancerous tumor inside a 10 × 10 × 30 cm3 water phantom. The innermost layer of the tumor represents a necrotic region, where the metal nanoparticles uptake is assumed to be zero, arising from hypoxic conditions. The nanoparticles were defined using the mixture technique, where nanoparticles are added to the chemical composition of the tumor. A directional 2 × 2 cm2 monoenergetic photon beam was used with several energies ranging from 50 keV to 4000 keV. The dose enhancement factor (DEF) was measured for all three metal nanoparticles under all beam energies. The maximum DEF was ~7 for silver nanoparticles with the 50 keV beam energy at the highest nanoparticle concentration of 30 mg/g of water. Gold followed the same trend as it registered the highest DEF at the 50 keV beam energy with the highest concentration of nanoparticles at 30 mg/g, while gadolinium registered the highest at 100 keV.

1 September 2018 in Results in Physics
Verified
Journal Article
Open access
EBEssam Banoqitah
Essam Banoqitah
ETEslam Taha
Eslam Taha
EEEzzat Elmoujarkach
Ezzat Elmoujarkach
SASahar Alsebaie
Sahar Alsebaie
ASAhmad Subahi
Ahmad Subahi
SAShaza Alsharif
Shaza Alsharif