Dinesh Rotake

Dr. Dinesh Rotake

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2022 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Closed access
DRDinesh Rotake
Dinesh Rotake
PGPartha Pratim Goswami
Partha Pratim Goswami
SSShiv Govind Singh
Shiv Govind Singh

15 October 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
JZJitendra B. Zalke
Jitendra B. Zalke
MBManish L Bhaiyya
Manish L Bhaiyya
PJPooja Anil Kumar Jain
Pooja Anil Kumar Jain
DSDevashree Naresh Sakharkar
Devashree Naresh Sakharkar
JKJayu Kalambe
Jayu Kalambe
SSShiv Govind Singh
Shiv Govind Singh
Detecting urea is crucial for diagnosing related health conditions and ensuring timely medical intervention. The addition of machine learning (ML) technologies has completely changed the field of biochemical sensing, providing enhanced accuracy and reliability. In the present work, an ML-assisted screen-printed, flexible, electrochemical, non-enzymatic biosensor was proposed to quantify urea concentrations. For the detection of urea, the biosensor was modified with a multi-walled carbon nanotube-zinc oxide (MWCNT-ZnO) nanocomposite functionalized with copper oxide (CuO) micro-flowers (MFs). Further, the CuO-MFs were synthesized using a standard sol-gel approach, and the obtained particles were subjected to various characterization techniques, including X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), and Fourier transform infrared (FTIR) spectroscopy. The sensor’s performance for urea detection was evaluated by assessing the dependence of peak currents on analyte concentration using cyclic voltammetry (CV) at different scan rates of 50, 75, and 100 mV/s. The designed non-enzymatic biosensor showed an acceptable linear range of operation of 0.5–8 mM, and the limit of detection (LoD) observed was 78.479 nM, which is well aligned with the urea concentration found in human blood and exhibits a good sensitivity of 117.98 mA mM−1 cm−2. Additionally, different regression-based ML models were applied to determine CV parameters to predict urea concentrations experimentally. ML significantly improves the accuracy and reliability of screen-printed biosensors, enabling accurate predictions of urea levels. Finally, the combination of ML and biosensor design emphasizes not only the high sensitivity and accuracy of the sensor but also its potential for complex non-enzymatic urea detection applications. Future advancements in accurate biochemical sensing technologies are made possible by this strong and dependable methodology.


1 June 2020 in IET Nanobiotechnology
Verified
Journal Article
Open access
PDF file
DRDinesh Rotake
Dinesh Rotake
ADAnand Darji
Anand Darji
NKNitin Kale
Nitin Kale
In this study, the authors demonstrate the fabrication, calibration, and testing of a piezoresistive microcantilever‐based sensor for biomedical microelectromechanical system (BioMEMS) application. To use any sensor in BioMEMS application requires surface modification to capture the targeted biomolecules. The surface alteration comprises self‐assembled monolayer (SAM) formation on gold (Au)/chromium (Cr) thin films. So, the Au/Cr coating is essential for most of the BioMEMS applications. The fabricated sensor uses the piezoresistive technique to capture the targeted biomolecules with the SAM/Au/Cr layer on top of the silicon dioxide layer. The stiffness ( k ) of the cantilever‐based biosensor is a crucial design parameter for the low‐pressure range and also influence the sensitivity of the microelectromechanical system‐based sensor. Based on the calibration data, the average stiffness of the fabricated microcantilever with and without Au/Cr thin film is 141.39 and 70.53 mN/m, respectively, which is well below the maximum preferred range of stiffness for BioMEMS applications. The fabricated sensor is ultra‐sensitive and selective towards Hg 2+ ions in the presence of other heavy metal ions (HMIs) and good enough to achieve a lower limit of detection 0.75 ng/ml (3.73 pM/ml).

1 January 2018 in Materials Today: Proceedings
Verified
Journal Article
Closed access
DRDinesh Rotake
Dinesh Rotake
ADA.D. Darji
A.D. Darji

26 April 2023 in Analytica Chimica Acta
Verified
Journal Article
Closed access
TGTanmoya Nemai Ghosh
Tanmoya Nemai Ghosh
DRDinesh Rotake
Dinesh Rotake
SKSaurabh Kumar
Saurabh Kumar
IKInderjeet Kaur
Inderjeet Kaur
SSShiv Govind Singh
Shiv Govind Singh