2 October 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
KSKuntal Satpathi
Kuntal Satpathi
YYYew Ming Yeap
Yew Ming Yeap
AUAbhisek Ukil
Abhisek Ukil
NGNagesh Geddada
Nagesh Geddada
The transient response of the voltage source converter (VSC) interfaced dc system is significantly different from the ac counterpart. The rapid discharge current from the dc-link capacitors and the vulnerability of the freewheeling diodes during the short circuit in dc grid demand that the transient detection algorithm executes within a few milliseconds. The rapidly rising fault current in the dc grid is expected to have high-frequency components which might be an effective indicator of the transient condition. This paper presents quantitative investigation of the high-frequency components utilizing short-time Fourier transform (STFT) during transient conditions. Detailed operating principles with various factors affecting the STFT operation such as ripple content of the input dc signal and window type and length have been thoroughly investigated. STFT algorithm is able to detect low-impedance faults within 1 ms and high-impedance faults in 2 ms. Moreover, it is able to distinguish between short-circuit fault and less severe transient conditions such as sudden load change. The STFT algorithm is evaluated analytically and subsequently applied to a MATLAB/Simulink based dc test system. It is further validated and substantiated with the real fault current data obtained from a scaled-down experimental testbed. Sensitivity analysis and comparison with the existing frequency-domain-based fault-detection method are done to support the efficacy of the proposed method.

29 December 2017 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
KSKuntal Satpathi
Kuntal Satpathi
AUAbhisek Ukil
Abhisek Ukil
Josep PouJosep Pou
Josep Pou
Ease of integration of the variable speed diesel generators resulting in substantial reduction of the fuel consumption is the key motivation for the development of the dc shipboard power system (SPS). One of the impediments to the widespread adoption of the dc SPS, however, has been the lack of comprehensive fault management strategies during the short-circuit faults. Such strategies comprise of fault detection, fault isolation, and reconfiguration of dc SPS. In the existing literature, all these aspects of fault management are dealt independently and mostly assuming ideal conditions. All the strategies are of utmost importance and it is needed to study them under a common framework which is the aim of this paper. This paper starts with a brief discussion on the characteristics of dc SPS along with recent modeling techniques. Subsequently, this paper describes the short-circuit fault studies, fault characteristics, and protection requirements. Finally, this paper outlines the working principle, advantages, and limitations of the fault detection, isolation, and reconfiguration strategies developed for the dc power system and analyzes their suitability to the dc SPS. This paper is concluded by identifying the future research trends needed for the development of the short-circuit fault management strategies of dc SPS for critical marine missions.

23 January 2018 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
YYYew Ming Yeap
Yew Ming Yeap
NGNagesh Geddada
Nagesh Geddada
KSKuntal Satpathi
Kuntal Satpathi
AUAbhisek Ukil
Abhisek Ukil
The rapid discharge of a dc-link capacitor of the voltage-source converter (VSC)-based dc system is the primary indication of the fault condition. Apart from the time-domain analysis, frequency-domain analysis of the fault current could also be utilized for dc fault detection, as the rapidly rising fault current is expected to have high-frequency components. This paper proposes two fault detection methods and compares their performances with the wavelet transform. The first method is the time-domain analysis of the dc-link capacitor discharge and is termed as the capacitive discharge technique. The relationship between the dc line current and the behavior of the dc-link capacitor is measured in terms of a correlation coefficient, whose value can be used to establish a fault basis. The second method is the frequency-domain-based short-time Fourier transform, which is used for quantitative analysis of high-frequency components in the fault current. These methods are extensively analyzed and compared using a scaled-down VSC-based dc system experimental test setup. Comparison has been done based on fault detection time, sensitivity to fault parameters, influence of sampling frequency, and computation speed. Furthermore, the selectivity of the fault detection methods is studied on the multiterminal dc systems of two different topologies (ring and radial), modeled in PSCAD/EMTDC. The experimental and simulation results substantiate the applicability of all the methods to the dc system. Brief comparative analysis with the di/dt method is also presented to highlight the advantages of the proposed methods.

2 September 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Yu WangYu Wang
Yu Wang
SMSuman Mondal
Suman Mondal
CDChao Deng
Chao Deng
KSKuntal Satpathi
Kuntal Satpathi
Yan XuYan Xu
Yan Xu
SDSouvik Dasgupta
Souvik Dasgupta
Bidirectional interlinking converters (BICs) are building blocks of the networked ac/dc microgrids (ac/dc NMGs). Such BICs are controlled using the communication assisted cooperative control thus forming tightly coupled cyber-physical systems (CPSs). One of lethal problems in such CPS is its vulnerability to cyber-attacks. In this article, a cyber-resilient cooperative control for BICs in ac/dc NMGs is proposed to enhance the system resilience under false signal injection attacks. The proposed control can maintain the frequency/voltage regulation and real/reactive power sharing among multiple BICs under both single and multiple node attacks. The suitability of the proposed method is supported by the stability analysis using Lyapunov methods. Efficacy of the proposed method is demonstrated by the controller hardware-in-the-loop (CHIL) experiment. An ac/dc NMG with four BICs is developed in the OPAL-RT-based real-time simulator. The cyber-resilient controllers are implemented on four commercial programmable logic controllers by B&R automation. The CHIL-based experimental results support the effectiveness of the proposed controller under various attack scenarios.

21 April 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
DLDongyu Li
Dongyu Li
AUAbhisek Ukil
Abhisek Ukil
KSKuntal Satpathi
Kuntal Satpathi
YYYew Ming Yeap
Yew Ming Yeap
The short circuit fault in dc power system typically generate fast-growing transient current which may cause serious damage for dc grid and power electronic equipment. Besides, the protection of dc system is not as mature as the ac system. Thus, dc grid requires a high speed and robust fault detection method. In this paper, a frequency-domain fault detection method is proposed based on S transform (ST), which is able to detect faults within 0.3~ms. It consists of high-frequency detection, which is responsible for fast response due to high time resolution, and low-frequency detection which is used to differentiate faults from other transient conditions. The high-frequency spectrum is obtained by introducing a correction factor into a Gaussian function in the calculation process of ST. This theoretical background of the ST-based fault detection method is presented in details. It is applied to a multi-terminal dc (MTDC) system on MATLAB/Simulink. The simulation results are verified on a point-to-point (P2P) experimental setup with scaled-down voltage. Comparative analysis of the detection time with other dc fault detection methods, namely, based on wavelet transform (WT) and short-time Fourier transform (STFT) substantiates the effectiveness of this method.

4 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
Javed AhmadJaved Ahmad
Javed Ahmad
MZMohammad Zaid
Mohammad Zaid
ADIL SARWARADIL SARWAR
ADIL SARWAR
Chang-Hua LinChang-Hua Lin
Chang-Hua Lin
MAMohammed Asim
Mohammed Asim
BABasem Alamri
Basem Alamri
The growth of renewable energy in the last two decades has led to the development of new power electronic converters. The DC microgrid can operate in standalone mode, or it can be grid-connected. A DC microgrid consists of various distributed generation (DG) units like solar PV arrays, fuel cells, ultracapacitors, and microturbines. The DC-DC converter plays an important role in boosting the output voltage in DC microgrids. DC-DC converters are needed to boost the output voltage so that a common voltage from different sources is available at the DC link. A conventional boost converter (CBC) suffers from the problem of limited voltage gain, and the stress across the switch is usually equal to the output voltage. The output from DG sources is low and requires high-gain boost converters to enhance the output voltage. In this paper, a new high-gain DC-DC converter with quadratic voltage gain and reduced voltage stress across switching devices was proposed. The proposed converter was an improvement over the CBC and quadratic boost converter (QBC). The converter utilized only two switched inductors, two capacitors, and two switches to achieve the gain. The converter was compared with other recently developed topologies in terms of stress, the number of passive components, and voltage stress across switching devices. The loss analysis also was done using the Piecewise Linear Electrical Circuit Simulation (PLCES). The experimental and theoretical analyses closely agreed with each other.