The objective of this study was to develop a rapid, reproducible, and robust method for detecting Salmonella enterica serotype Enteritidis in poultry samples. First, for the extraction and purification of DNA from the preenrichment culture, four methods (boiling, alkaline lysis, Nucleospin, and Dynabeads DNA Direct System I) were compared. The most effective method was then combined with a real-time PCR method based on the double-stranded DNA binding dye SYBR Green I used with the ABI Prism 7700 system. The specificity of the reaction was determined by the melting temperature (
T
m ) of the amplicon obtained. The experiments were conducted both on samples of chicken experimentally contaminated with serotype Enteritidis and on commercially available poultry samples, which were also used for comparisons with the standard cultural method (i.e., ISO 6579/2001). The results of comparisons among the four DNA extraction methods showed significant differences except for the results from the boiling and Nucleospin methods (the two methods that produced the lowest threshold cycles). Boiling was selected as the preferred extraction method because it is the simplest and most rapid. This method was then combined with SYBR Green I real-time PCR, using primers SEFA-1 and SEFA-2. The specificity of the reaction was confirmed by the
T
m , which was consistently specific for the amplicon obtained; the mean peak
T
m obtained with curves specific for serotype Enteritidis was 82.56 ± 0.22°C. The standard curve constructed using the mean threshold cycle and various concentrations of serotype Enteritidis (ranging from 10 3 to 10 8 CFU/ml) showed good linearity ( R2 = 0.9767) and a sensitivity limit of less than 10 3 CFU/ml. The results of this study demonstrate that the SYBR Green I real-time PCR constitutes an effective and easy-to-perform method for detecting serotype Enteritidis in poultry samples.
15 October 2009 in Applied and Environmental Microbiology
Botulinum neurotoxin (BoNT), the most toxic substance known, is produced by the spore-forming bacteriumClostridium botulinumand, in rare cases, also by some strains ofClostridium butyricumandClostridium baratii. The standard procedure for definitive detection of BoNT-producing clostridia is a culture method combined with neurotoxin detection using a standard mouse bioassay (SMB). The SMB is highly sensitive and specific, but it is expensive and time-consuming and there are ethical concerns due to use of laboratory animals. PCR provides a rapid alternative for initial screening for BoNT-producing clostridia. In this study, a previously described multiplex PCR assay was modified to detect all type A, B, E, and F neurotoxin genes in isolated strains and in clinical, food, environmental samples. This assay includes an internal amplification control. The effectiveness of the multiplex PCR method for detecting clostridia possessing type A, B, E, and F neurotoxin genes was evaluated by direct comparison with the SMB. This method showed 100% inclusivity and 100% exclusivity when 182 BoNT-producing clostridia and 21 other bacterial strains were used. The relative accuracy of the multiplex PCR and SMB was evaluated using 532 clinical, food, and environmental samples and was estimated to be 99.2%. The multiplex PCR was also used to investigate 110 freshly collected food and environmental samples, and 4 of the 110 samples (3.6%) were positive for BoNT-encoding genes.
1 October 2015 in International Journal of Food Microbiology
An electrochemical enzyme-linked immunosorbent assay (ELISA) coupled with flow injection analysis (ELISA-FIA) and a PCR-based method using ST11 and ST15 primers for detecting salmonellae in meat were evaluated in comparison with the International Organization for Standardization (ISO) culture method. The methods were applied to experimentally contaminated and naturally contaminated meat samples. The results showed that both ELISA-FIA and PCR allowed detection of salmonella in a product contaminated with a low number of the microorganisms (1 to 10 salmonellae/25 g) after only 5 h of incubation of preenrichment broth, and they were just as effective as the ISO method.
: Salmonella has represented the most common and primary cause of food poisoning in many countries for at least over 100 years. Its detection is still primarily based on traditional microbiological culture methods which are labor-intensive, extremely time consuming, and not suitable for testing a large number of samples. Accordingly, great efforts to develop rapid, sensitive and specific methods, easy to use, and suitable for multi-sample analysis, have been made and continue. Biosensor-based technology has all the potentialities to meet these requirements. In this paper, we review the features of the electrochemical immunosensors, genosensors, aptasensors and phagosensors developed in the last five years for Salmonella detection, focusing on the critical aspects of their application in food analysis.
1 August 2014 in International Journal of Food Microbiology