Marina Vergara

Ms. Marina Vergara

UPV Universitat Politècnica de València, Valencia, España
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
HMHECTOR ESPINÓS MORATÓ
HECTOR ESPINÓS MORATÓ
DCDavid Cascales
David Cascales
MVMarina Vergara
Marina Vergara
ÁHÁngel Hernández-Martínez
Ángel Hernández-Martínez
JBJosé María Benlloch Baviera
José María Benlloch Baviera
Maria Jose Rodriguez-AlvarezMaria Jose Rodriguez-Alvarez
Maria Jose Rodriguez-Alvarez
Positron emission tomography (PET) is a functional non-invasive imaging modality that uses radioactive substances (radiotracers) to measure changes in metabolic processes. Advances in scanner technology and data acquisition in the last decade have led to the development of more sophisticated PET devices with good spatial resolution (1–3 mm of full width at half maximum (FWHM)). However, there are involuntary motions produced by the patient inside the scanner that lead to image degradation and potentially to a misdiagnosis. The adverse effect of the motion in the reconstructed image increases as the spatial resolution of the current scanners continues improving. In order to correct this effect, motion correction techniques are becoming increasingly popular and further studied. This work presents a simulation study of an image motion correction using a frame-based algorithm. The method is able to cut the acquired data from the scanner in frames, taking into account the size of the object of study. This approach allows working with low statistical information without losing image quality. The frames are later registered using spatio-temporal registration developed in a multi-level way. To validate these results, several performance tests are applied to a set of simulated moving phantoms. The results obtained show that the method minimizes the intra-frame motion, improves the signal intensity over the background in comparison with other literature methods, produces excellent values of similarity with the ground-truth (static) image and is able to find a limit in the patient-injected dose when some prior knowledge of the lesion is present.

12 May 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
MVMarina Vergara
Marina Vergara
ARAhmadreza Rezaei
Ahmadreza Rezaei
GSGeorg Schramm
Georg Schramm
Maria Jose Rodriguez-AlvarezMaria Jose Rodriguez-Alvarez
Maria Jose Rodriguez-Alvarez
JBJose Maria Benlloch Baviera
Jose Maria Benlloch Baviera
JNJohan Nuyts
Johan Nuyts
Several research groups are studying organ-dedicated limited angle positron emission tomography (PET) systems to optimize performance-cost ratio, sensitivity, access to the patient, and/or flexibility. Often open systems are considered, typically consisting of two detector panels of various sizes. Such systems provide incomplete sampling due to limited angular coverage and/or truncation, which leads to artifacts in the reconstructed activity images. In addition, these organ-dedicated PET systems are usually stand-alone systems, and as a result, no attenuation information can be obtained from anatomical images acquired in the same imaging session. It has been shown that the use of time-of-flight (TOF) information reduces incomplete data artifacts and enables the joint estimation of the activity and the attenuation factors. In this work, we explore with simple 2-D simulations the performance and stability of a joint reconstruction algorithm, for imaging with a limited angle PET system. The reconstruction is based on the so-called maximum-likelihood attenuation correction factors (MLACF) algorithm and uses linear attenuation coefficients in a known-tissue-class region to obtain absolute quantification. Different panel sizes and different TOF resolutions are considered. The noise propagation is compared to that of MLEM reconstruction with exact attenuation correction (AC) for the same PET system. The results show that with good TOF resolution, images of good visual quality can be obtained. If also a good scatter correction can be implemented, quantitative PET imaging will be possible. Further research, in particular on scatter correction, is required.

1 October 2019
Verified
Conference Paper
Closed access
ALAndres Larroza
Andres Larroza
LMLaura Moliner
Laura Moliner
JAJuan M. Alvarez-Gomez
Juan M. Alvarez-Gomez
SOSandra Oliver
Sandra Oliver
HEHector Espinos-Morato
Hector Espinos-Morato
Maria Jose Rodriguez-AlvarezMaria Jose Rodriguez-Alvarez
Maria Jose Rodriguez-Alvarez
Synthetic computed tomography (CT) images derived from magnetic resonance images (MRI) are of interest for radiotherapy planning and positron emission tomography (PET) attenuation correction. In recent years, deep learning implementations have demonstrated improvement over atlas-based and segmentation-based methods. Nevertheless, several open questions remain to be addressed, such as which is the best of MRI sequences and neural network architectures. In this work, we compared the performance of different combinations of two common MRI sequences (T1- and T2-weighted), and three state-of-the-art neural networks designed for medical image processing (Vnet, HighRes3dNet and ScaleNet). The experiments were conducted on brain datasets from a public database. Our results suggest that T1 images perform better than T2, but the results further improve when combining both sequences. The lowest mean average error over the entire head (MAE = 101.76 ± 10.4 HU) was achieved combining T1 and T2 scans with HighRes3dNet. All tested deep learning models achieved significantly lower MAE (p < 0.01) than a well-known atlas-based method.

9 October 2021
Verified
Book Chapter
Closed access
PDF file
HMHECTOR ESPINÓS MORATÓ
HECTOR ESPINÓS MORATÓ
DCDavid Cascales
David Cascales
MVMarina Vergara
Marina Vergara
Maria Jose Rodriguez-AlvarezMaria Jose Rodriguez-Alvarez
Maria Jose Rodriguez-Alvarez