Introduction: The design and development of a novel dynamic hand orthosis that allows individual and progressive adaptation to the patient’s condition require knowledge about the maximum voluntary contraction forces of the fingers. The following work presents a test setup and procedure for determination of isometric finger contraction forces during flexion depending on various finger positions and finger tasks. Methods: The test setup places hand and fingers in certain positions (position 0: grasping of a plate; position 1-3: circular grasping of cylinders of three different diameters). The force measurement is carried out using pressure sensing: A capacitive force sensor is placed on each fingertip. To perform various finger tasks, the subjects are asked for isometric contraction of defined finger groups and single fingers against the boundary system. For proof of the concept, measurements are performed with six subjects and compared with reference values from the literature. Results: The separated finger force of each finger can be captured during the finger tasks in varying positions. Furthermore, the total finger force of all active fingers can be determined. It is shown that the total finger force during contraction of all fingers (IMRLtask; 78.4N ± 25.8N, d2) is higher than during contraction of the index finger (25.8N ± 3.4N, d2). Furthermore, the single finger force of the index finger is higher than the index finger activity in IMRL-task. The results also show a tendency for the finger contraction force to increase with increasing flexion. Further investigations may require improvements to the method. In this proof of concept, this potential is revealed and discussed. However, the functionality of the test setup and procedure can be demonstrated.
Prosthesis treatment requires the close interaction of different actors. In fitting prostheses to patients, special attention is given to the manufacturing of the socket. The continuous development of the technologies involved in the fitting and optimization of prostheses is shown in the literature. The assessment of orthopedic technicians and their influence in the process is thus far largely unexplored. Ten orthopedic technicians were interviewed about the socket fitting process after transfemoral amputation. The research goal was to clarify the socket treatment process with regards to the German context. The results showed that the orthopedic technicians focussing on the patient during the fitting process. This study underlines the importance of interaction and empathy. Volume fluctuations are decisive within the treatment process and are interactively influenced by various factors. Furthermore, the research emphasizes the need for appropriate assistive technologies and the potential for the further development of existing systems.
The aim of this study is a standardizable, sensor-integrating feather key (SiFK) that can measure the transmitted circumferential forces (and subsequently the torque) in a feather key connection without calibration for the respective application. The study proposes a new design for a feather key with a targeted stiffness condition. The geometry of the machine element is adapted by means of topology optimization so that a small number of strain gauges is sufficient to record the complete deformation state. The latter can then be used to determine the transmitted circumferential forces using a simple mechanical model. The work also includes efficient data reduction, subsequent wireless transmission, and energy harvesting using piezoelectric energy converters within the force direction. The required sensory and microelectronic components are integrated into the system in a space-neutral manner without impairing the main function of the machine element. The aim of the current work is to show a design kit to develop a SiFK to measure the circumferential forces and calculate the transmittable torque.