In this paper, a novel data augmentation method for time-series classification is proposed. In the introduced method, a new time-series is obtained in warped space between suboptimally aligned input examples of different lengths. Specifically, the alignment is carried out constraining the warping path and reducing its flexibility. It is shown that the resultant synthetic time-series can form new class boundaries and enrich the training dataset. In this work, the comparative evaluation of the proposed augmentation method against related techniques on representative multivariate time-series datasets is presented. The performance of methods is examined using the nearest neighbor classifier with the dynamic time warping (NN-DTW), LogDet divergence-based metric learning with triplet constraints (LDMLT), and the recently introduced time-series cluster kernel (NN-TCK). The impact of the augmentation on the classification performance is investigated, taking into account entire datasets and cases with a small number of training examples. The extensive evaluation reveals that the introduced method outperforms related augmentation algorithms in terms of the obtained classification accuracy.
20 December 2023 in Swarm and Evolutionary Computation
We focus on gesture recognition based on 3D information in the form of a point cloud of the observed scene. A descriptor of the scene is built on the basis of a Viewpoint Feature Histogram (VFH). To increase the distinctiveness of the descriptor the scene is divided into smaller 3D cells and VFH is calculated for each of them. A verification of the method on publicly available Polish and American sign language datasets containing dynamic gestures as well as hand postures acquired by a time-of-flight (ToF) camera or Kinect is presented. Results of cross-validation test are given. Hand postures are recognized using a nearest neighbour classifier with city-block distance. For dynamic gestures two types of classifiers are applied: (i) the nearest neighbour technique with dynamic time warping and (ii) hidden Markov models. The results confirm the usefulness of our approach.
13 November 2015 in IEEE Signal Processing Letters
The proliferation of electronic means of communication entails distortion of visual information carried by processed images. Therefore, automatic evaluation of image perceptual quality in a way that is consistent with human perception is important. In this letter, an approach to full-reference image quality assessment (IQA) is proposed. The perceptual quality of the image is evaluated using an aggregated decision of several IQA measures. An optimization problem of designing a decision fusion of 18 IQA measures is defined and solved using a genetic algorithm. Obtained fusion strategies are evaluated on widely used large image benchmarks and compared with 32 state-of-the-art IQA approaches. Results of comparison reveal that the proposed approach outperforms other competing techniques.
Background: The perceptual quality of magnetic resonance (MR) images influences diagnosis and may compromise the treatment. The purpose of this study was to evaluate how the image quality changes influence the interobserver variability of their assessment. Methods: For the variability evaluation, a dataset containing distorted MRI images was prepared and then assessed by 31 experienced medical professionals (radiologists). Differences between observers were analyzed using the Fleiss’ kappa. However, since the kappa evaluates the agreement among radiologists taking into account aggregated decisions, a typically employed criterion of the image quality assessment (IQA) performance was used to provide a more thorough analysis. The IQA performance of radiologists was evaluated by comparing the Spearman correlation coefficients, ρ, between individual scores with the mean opinion scores (MOS) composed of the subjective opinions of the remaining professionals. Results: The experiments show that there is a significant agreement among radiologists (κ=0.12; 95% confidence interval [CI]: 0.118, 0.121; P<0.001) on the quality of the assessed images. The resulted κ is strongly affected by the subjectivity of the assigned scores, separately presenting close scores. Therefore, the ρ was used to identify poor performance cases and to confirm the consistency of the majority of collected scores (ρmean = 0.5706). The results for interns (ρmean = 0.6868) supports the finding that the quality assessment of MR images can be successfully taught. Conclusions: The agreement observed among radiologists from different imaging centers confirms the subjectivity of the perception of MR images. It was shown that the image content and severity of distortions affect the IQA. Furthermore, the study highlights the importance of the psychosomatic condition of the observers and their attitude.