This study compared and analyzed changes in the microclimate and thermal environment inside single-span greenhouses covered with a single layer of plastic film, polycarbonate (PC), and glass. The results of the experiment show that the PC-covered greenhouse was the most favorable for managing the nighttime heating effect during the cold season. However, the glass-covered greenhouse was found to be the most favorable for managing the cooling effect during the hot season. Although the plastic-covered greenhouse was inexpensive and easy to install, the air temperature inside varied significantly, and it was difficult to control its indoor environment. The thermal load leveling values showed that the PC-covered greenhouse had the lowest variation, confirming its superiority in terms of environmental control and energy savings. In terms of the overall heat transfer, heat was generally transferred from the interior to the exterior of the greenhouses. In the plastic-covered greenhouse, however, heat was transferred in the opposite direction at night due to the influence of radiant cooling. The occurrence of the minimum and maximum heat transfer values had a tendency similar to that of the occurrence of the minimum and maximum air temperatures inside the greenhouses.
Greenhouses are important for stable food production, but require large amounts of energy to maintain their microclimate in regions with harsh climates. This study assessed the internal thermal insulation performance of thermal curtains in double-layered plastic greenhouses in Korea in winter using cover surface temperature changes and heat transfer coefficients (U values). The thermal curtain performance increased as the temperatures of the inner cover surface increased and the outer cover surface decreased. The outer cover surface temperature with thermal curtains was almost uniformly 1.9 °C lower than that without thermal curtains, whereas the inner cover surface temperature was higher, demonstrating the warming effect of thermal curtain use. Under a constant indoor and outdoor air temperature difference, the daily average heating energy consumption was directly proportional to the U value. The U values were 2.76 W m−2 °C−1 with thermal curtains and 3.85 W m−2 °C−1 without thermal curtains. In double-layered plastic greenhouses that were covered with 0.1-mm-thick polyethylene, incorporating thermal curtains at night resulted in energy savings of about 28.7%, which was related to the decrease in U values. Installing and using thermal curtains at night in winter is a highly economical method for heating savings. These results can be used to promote energy savings in greenhouses in harsh climates.
This study comprehensively analyzed the heat loss and total heat transfer coefficient (U-value) of a single-span experimental plastic greenhouse covered with a double layer of 0.1 mm thick polyethylene. The air temperature and heat flux (W m−2) of the greenhouse components were measured from 18:00 to 06:00, and the energy balance equations under steady-state conditions were determined. The heat flux and U-value of the roof, sides, front and rear, and floor of the greenhouse were determined and compared. The results showed that these values for the roof play an important role in determining the heat load in the greenhouse, and that the average heat transfer through the floor is very small. The average U-value of the greenhouse cover is a comprehensive value which takes the U-values of the roof, sides, and front and rear into account through the use of an area–weighted average method. Finally, an average U-value of 3.69 W m−2 °C −1 was obtained through the analysis of the variations in the U-value, as it is related to the difference in air temperature between the interior and exterior of the greenhouse, as well as to the outdoor wind speed. The relationships between the average U-value and those of the roof, sides, and front and rear of the experimental greenhouse were modeled, and were shown to have a highly linear relationship.
Natural ventilation is the most cost-effective environmental control method for protected horticulture. To overcome the issues associated with high temperatures in greenhouses, analyzing their ventilation characteristics and maximizing their natural ventilation performance are essential. Therefore, in this study, the natural ventilation performance of arched single-span plastic greenhouses with screened side openings was empirically investigated. Three identical single-span plastic greenhouses were used in this study, each with different side-opening heights. Temperature and wind-speed data were collected, and the ventilation-volume flow rate was calculated considering both buoyancy and wind forces. The natural ventilation performance of the greenhouses was strongly and positively correlated with the ventilation-area ratio and outdoor wind speed. The ventilation rate increased linearly with an increase in the ventilation-area ratio and high outdoor wind speeds. However, the association between ventilation performance and indoor–outdoor temperature differences was not strong. When the ratios of ventilation areas in the greenhouse were changed to 0.08, 0.19, and 0.29, the average indoor–outdoor temperature differences were 14.0, 10.1, and 7.7 °C, respectively, and the ventilation rates were 0.0081, 0.0196, and 0.0315 m3 s−1 m−2, respectively. The proportion of wind in the total ventilation performance was high with a low ratio of ventilation openings and high outdoor wind speeds. However, the proportion of the buoyancy was high, with a high ratio of ventilation openings and a large indoor–outdoor temperature difference. Overall, this study provides foundational insights for optimizing the design and evaluation of ventilation openings in greenhouses, considering the outdoor wind speed.
1 June 2015 in Protected Horticulture and Plant Factory