Marco Girolami

Dr. Marco Girolami

IRCCS Rizzoli Orthopaedic Institute, 40136 Bologna, Italy
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2018 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
MGMarco Girolami
Marco Girolami
SBStefano Boriani
Stefano Boriani
SBStefano Bandiera
Stefano Bandiera
Giovanni Barbanti BrodanoGiovanni Barbanti Brodano
Giovanni Barbanti Brodano
RGRiccardo Ghermandi
Riccardo Ghermandi
Alessandro GasbarriniAlessandro Gasbarrini
Alessandro Gasbarrini

29 April 2024 in Microorganisms
Verified
Journal Article
Open access
PDF file
CACrombé Amandine
Crombé Amandine
DFDavid Fadli
David Fadli
RCRoberta Clinca
Roberta Clinca
GRGiorgio Reverchon
Giorgio Reverchon
LCLuca Cevolani
Luca Cevolani
Paolo SpinnatoPaolo Spinnato
Paolo Spinnato
Spondylodiscitis is defined by infectious conditions involving the vertebral column. The incidence of the disease has constantly increased over the last decades. Imaging plays a key role in each phase of the disease. Indeed, radiological tools are fundamental in (i) the initial diagnostic recognition of spondylodiscitis, (ii) the differentiation against inflammatory, degenerative, or calcific etiologies, (iii) the disease staging, as well as (iv) to provide clues to orient towards the microorganisms involved. This latter aim can be achieved with a mini-invasive procedure (e.g., CT-guided biopsy) or can be non-invasively supposed by the analysis of the CT, positron emission tomography (PET) CT, or MRI features displayed. Hence, this comprehensive review aims to summarize all the multimodality imaging features of spondylodiscitis. This, with the goal of serving as a reference for Physicians (infectious disease specialists, spine surgeons, radiologists) involved in the care of these patients. Nonetheless, this review article may offer starting points for future research articles.

23 July 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
RGRiccardo Ghermandi
Riccardo Ghermandi
GTGiovanni Tosini
Giovanni Tosini
ALAlberto Lorenzi
Alberto Lorenzi
CGCristiana Griffoni
Cristiana Griffoni
LBLuigi La Barbera
Luigi La Barbera
Alessandro GasbarriniAlessandro Gasbarrini
Alessandro Gasbarrini
CFR-PEEK is gaining popularity in spinal oncological applications due to its reduction of imaging artifacts and radiation scattering compared with titanium, which allows for better oncological follow-up and efficacy of radiotherapy. We evaluated the use of these materials for the treatment of lumbar degenerative diseases (DDs) and considered the biomechanical potential of the carbon fiber in relation to its modulus of elasticity being similar to that of bone. Twenty-eight patients with DDs were treated using CRF-PEEK instrumentation. The clinical and radiographic outcomes were collected at a 12-month FU. Spinal fusion was evaluated in the CT scans using Brantigan scores, while the clinical outcomes were evaluated using VAS, SF-12, and EQ-5D scores. Out of the patients evaluated at the 12-month FU, 89% showed complete or almost certain fusion (Brantigan score D and E) and presented a significant improvement in all clinical parameters; the patients also presented VAS scores ranging from 6.81 ± 2.01 to 0.85 ± 1.32, EQ-5D scores ranging from 53.4 ± 19.3 to 85.0 ± 13.7, SF-12 physical component scores (PCSs) ranging from 29.35 ± 7.04 to 51.36 ± 9.75, and SF-12 mental component scores (MCSs) ranging from 39.89 ± 11.70 to 53.24 ± 9.24. No mechanical complications related to the implant were detected, and the patients reported a better tolerance of the instrumentation compared with titanium. No other series of patients affected by DD that was stabilized using carbon fiber implants have been reported in the literature. The results of this pilot study indicate the efficacy and safety of these implants and support their use also for spinal degenerative diseases.

17 October 2022 in Current Oncology
Verified
Journal Article
Open access
PDF file
SBStefano Bandiera
Stefano Bandiera
LNLuigi Emanuele Noli
Luigi Emanuele Noli
CGCristiana Griffoni
Cristiana Griffoni
GTGiovanni Tosini
Giovanni Tosini
ECElisa Carretta
Elisa Carretta
Alessandro GasbarriniAlessandro Gasbarrini
Alessandro Gasbarrini
En bloc resection consists in the surgical removal of a vertebral tumor in a single piece with a sufficient margin, to improve survival and reduce recurrence rate. This procedure is technically demanding and correlates with a high complication rate. The purpose of this study is to investigate the risk factors for complications in en bloc resection and evaluate if benefits overcome the risks in term of overall survival. We retrospectively analyzed prospectively collected data of patients treated with en bloc resection between 1980 and 2021. Complications were classified according to SAVES-V2. Overall Survival was estimated using Kaplan-Meier method. A total of 149 patients out of 298 (50%) suffered from at least one complication. Moreover, 220 adverse events were collected (67 intraoperative, 82 early post-operative, 71 late post-operative), 54% of these were classified as grade 3 (in a severity scale from 1 to 6). Ten years overall survival was 67% (95% CI 59–74). The occurrence of relapses was associated to an increased risk of mortality with OR 3.4 (95% CI 2.1–5.5), while complications did not affect the overall survival. Despite a high complication rate, en bloc resection allows for a better control of disease and should be performed in selected patients by specialized surgeons.

13 October 2022 in Nutrients
Verified
Journal Article
Open access
PDF file
MFMaria Fusaro
Maria Fusaro
ESEnrico Schileo
Enrico Schileo
GCGianluigi Crimi
Gianluigi Crimi
AAAndrea Aghi
Andrea Aghi
Alberto BazzocchiAlberto Bazzocchi
Alberto Bazzocchi
FTFulvia Taddei
Fulvia Taddei
In CKD and in the elderly, Vascular Calcifications (VC) are associated to cardiovascular events and bone fractures. VC scores at the abdominal aorta (AA) from lateral spine radiographs are widely applied (the 0–24 semiquantitative discrete visual score (SV) being the most used). We hypothesised that a novel continuum score based on quantitative computer-assisted tracking of calcifications (QC score) can improve the precision of the SV score. This study tested the repeatability and reproducibility of QC score and SV score. In forty-four patients with VC from an earlier study, five experts from four specialties evaluated the data twice using a dedicated software. Test–retest was performed on eight subjects. QC results were reported in a 0–24 scale to readily compare with SV. The QC score showed higher intra-operator repeatability: the 95% CI of Bland–Altman differences was almost halved in QC; intra-operator R2 improved from 0.67 for SV to 0.79 for QC. Inter-observer repeatability was higher for QC score in the first (Intraclass Correlation Coefficient 0.78 vs. 0.64), but not in the second evaluation (0.84 vs. 0.82), indicating a possible heavier learning artefact for SV. The Minimum Detectable Difference (MDD) was smaller for QC (2.98 vs. 4 for SV, in the 0–24 range). Both scores were insensitive to test–retest procedure. Notably, QC and SV scores were discordant: SV showed generally higher values, and an increasing trend of differences with VC severity. In summary, the new QC score improved the precision of lateral spine radiograph scores in estimating VC. We reported for the first time an estimate of MDD in VC assessment that was 25% lower for the new QC score with respect to the usual SV score. An ongoing study will determine whether this lower MDD may reduce follow-up times to check for VC progression.

13 October 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MGMarco Girolami
Marco Girolami
CGCristiana Griffoni
Cristiana Griffoni
EAEmanuela Asunis
Emanuela Asunis
LFLuigi Falzetti
Luigi Falzetti
SBStefano Bandiera
Stefano Bandiera
Alessandro GasbarriniAlessandro Gasbarrini
Alessandro Gasbarrini
The use of three-dimensional (3D)-printed custom-made implants is spreading in the orthopedics field for the reconstruction of bone losses or for joint replacement, thanks to their unparalleled versatility. In particular, this novel technology opens new perspectives to formulate custom-made fixation strategies for the upper cervical region, sacrum and pelvis, where reconstruction is challenging. We report and analyze the literature concerning upper cervical reconstruction with 3D-printed personalized implants after tumor surgery, and discuss two cases of patients where this technology was used to reconstruct the anterior column after extracapsular debulking of C2 recurrent chordoma at our institution.