Alessandro Rossi

Dr. Alessandro Rossi


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2000 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
MCMatteo Chiapasco
Matteo Chiapasco
SASilvio Abati
Silvio Abati
GRGiuseppe Ramundo
Giuseppe Ramundo
ARAlessandro Rossi
Alessandro Rossi
Eugenio RomeoEugenio Romeo
Eugenio Romeo
GVGiorgio Vogel
Giorgio Vogel

12 April 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AFAntonio Maria Fea
Antonio Maria Fea
MMMartina Menchini
Martina Menchini
ARAlessandro Rossi
Alessandro Rossi
CPChiara Posarelli
Chiara Posarelli
LMLorenza Malinverni
Lorenza Malinverni
MFMichele Figus
Michele Figus
The new XEN63 implant is a minimally invasive glaucoma surgery device with limited experience in real life. This retrospective study included open-angle glaucoma patients who underwent XEN63 implant, either alone or in combination with cataract surgery. Primary endpoints were the intraocular pressure (IOP) at month 3 and the incidence of serious adverse events. Twenty-three eyes of 23 patients were included. Mean age was 67.8 ± 15.3 years and 15 (65.2%) were women. Mean IOP was significantly lowered from 27.0 ± 7.8 mmHg at baseline to 12.2 ± 3.4 mmHg at month 3 (p < 0.0001). Mean IOP lowering was 40.8 ± 23.5%, with 14 (60.9%) and 16 (69.6%) eyes achieving an IOP lowering ≥30% and ≥20% without hypotensive medication, respectively. The number of hypotensive medications (NHM) was significantly reduced from 2.27 ± 0.94 drugs at baseline to 0.09 ± 0.42 drugs at month 3, p < 0.0001. Four (17.4%) eyes had hypotony (IOP ≤ 6 mmHg) at postoperative day one, which was successfully resolved without sequelae. Four (17.4%) eyes had choroidal detachment (3 at day 7 and 1 at day 15), which was successfully resolved with medical treatment, at the month 1 visit. Three (13.0%) eyes required needling (mean time for needling 35.6 ± 9.7 days). XEN63 significantly lowered IOP and reduced the NHM, with a good short-term safety profile.

Verified
Journal Article
Open access
PDF file
AFAntonio Maria Fea
Antonio Maria Fea
MMMartina Menchini
Martina Menchini
ARAlessandro Rossi
Alessandro Rossi
CPChiara Posarelli
Chiara Posarelli
LMLorenza Malinverni
Lorenza Malinverni
MFMichele Figus
Michele Figus
Background: Glaucoma surgery has significantly evolved over the last years. This paper aims to evaluate the midterm clinical outcomes of the XEN63 device in a real-world scenario. Methods: A retrospective clinical study was conducted on consecutive patients who underwent an XEN63 implant insertion, either alone or in combination with phacoemulsification. The primary endpoint was the mean intraocular pressure (IOP) at the month 18 visit. Results: Twenty-three eyes (23 patients) were included in the analysis. The preoperative IOP was significantly lowered from 27.0 ± 7.8 mmHg to 14.1 ± 3.4 mmHg at month 18 (p < 0.0001). At month 18, 14 (77.8%) and 11 (61.1%) eyes had an IOP ≤ 16 mmHg and ≤ 14 mmHg, respectively, without ocular hypotensive medication. The mean number of ocular hypotensive medication taken was significantly reduced from 2.3 ± 0.9 drugs at baseline to 1.0 ± 1.4 drugs at month 18 (p = 0.0020). Four (17.4%) eyes had hypotony at postoperative day 1, which was successfully resolved without sequelae. Four (17.4%) eyes underwent a needling procedure and four (17.4%) eyes underwent additional surgeries. Conclusions: The XEN63, either alone or in combination with cataract surgery, significantly lowered the IOP and reduced the need for ocular hypotensive drugs over a period of 18 months.

28 September 2023 in Expert Review of Medical Devices
Verified
Journal Article
Closed access
AFAntonio Maria Fea
Antonio Maria Fea
FRFederico Ricardi
Federico Ricardi
RCRossella Cariola
Rossella Cariola
ARAlessandro Rossi
Alessandro Rossi
Minimally invasive glaucoma surgeries (MIGS) are now a consolidated reality in many surgical units. The Hydrus Microstent is one of several MIGS devices bypassing trabecular outflow and had excellent results over the years. This article aims to review the key features of the Hydrus Microstent in terms of design, efficacy, and safety. The present review analyses the main characteristics of the device by evaluating the technical and physical details of its functioning. The evidence that supports a clinical decision summarizes the most influential clinical trials and the most accurate systematic reviews. The Hydrus device has been extensively studied regarding biocompatibility and outflow potential. The subsequent clinical studies have been well-built and proved that the device effectively reduces intraocular pressure (IOP) and the eyedrop load. The device covers almost a quarter of Schlemm's canal circumference, offering at least two advantages: cannulating the Schlemm's canal provides evidence that the device has been implanted correctly; covering a larger area potentially allows to target multiple collector channels or at least areas of active outflow. This scaffold may prove more effective in naïve patients or subjects who used antiglaucoma eyedrops for a limited period, as the prolonged use of hypotonic medications has been associated with the surgical failure of ab interno microhook trabeculotomy.

7 February 2020 in Translational Vision Science & Technology
Verified
Journal Article
Open access
PDF file
TRTommaso Rossi
Tommaso Rossi
SSStefano Saffioti
Stefano Saffioti
GAGiampiero Angelini
Giampiero Angelini
GQGiorgio Querzoli
Giorgio Querzoli
STSerena Telani
Serena Telani
GRGuido Ripandelli
Guido Ripandelli
Purpose: To assess whether the use of a patented, novel feedback device intended to accurately control phacoemulsification tip elongation is effective under varying machine settings and material resistance. Methods: Sculpt mode phaco (550-mm Hg Venturi pump; elongations, 35 and 70 µm) and quadrant settings (550-mm Hg Venturi pump; elongations, 15, 30, and 60 µm) were used in agar gel of incremental density (1%, 2%, 3%, and 6% in demineralized water). Dispersed lens fragments were also simulated with 6% agar gel spherules (2–5 mm in diameter; 550-mm Hg vacuum, and 60-µm elongation). Actual phaco tip elongation was measured on voltage readings from the piezoelectric crystals and compared to nominal elongation with feedback control off and on. Results: Mismatch between nominal and actual elongation when feedback control was off in sculpt mode varied between –13.51 µm and –23.07 µm of nominal elongation; in quadrant mode, mismatch varied between –2.79 µm and –20.41 µm. When the feedback control system was switched on, mismatch varied between –0.02 µm and +0.43 µm (P < 0.001 for all matchings). When the feedback system was off, the elongation mismatch among the 1%, 3%, and 6% agar was also statistically significant (P < 0.001). Elongation was 44.72 ± 4.16 µm with feedback control off and 60.02 ± 1.63 µm with it on (nominal elongation 60 µm; P < 0.001) when emulsifying agar 6% gel fragments. Dispersion of elongation data was also significantly wider when feedback control was turned off. Conclusions: A novel feedback control system effectively controls elongation accuracy regardless of the resistance offered by incremental agar gel concentrations. Translational Relevance: Implementing feedback control in phaco handpieces dramatically improves surgical accuracy. The translational value of this research relies on its immediate applicability to routine cataract surgery, resulting in a more appropriate use of ultrasound energy.

3 June 2021 in International Journal of Telemedicine and Applications
Verified
Journal Article
Open access
PDF file
RNRaffaele Nuzzi
Raffaele Nuzzi
DBDavide Bovone
Davide Bovone
FMFabio Maradei
Fabio Maradei
Paolo CaselgrandiPaolo Caselgrandi
Paolo Caselgrandi
ARAlessandro Rossi
Alessandro Rossi
Teleophthalmology (TO) consists of the clinical and therapeutic approach to the patient (e-Health) using informatic and telecommunication systems. Already widespread worldwide, it aims to improve patient care, expand the healthcare offer, and access to medical care by reducing overall costs. Despite the organizational, legal, and management difficulties, the substantial economic investments necessary for the start-up of equipped structures and efficient territorial services are amply rewarded by economic results and optimal services for professionals and patients. This review specifically analyses the current scenario of teleophthalmology, the points for and against its application in different sociodemographic realities, and in particular, the current and future fields of use.