Raúl González-Martín

Mr. Raúl González-Martín

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2023 in Journal of Chromatography A
Verified
Journal Article
Open access
RGRaúl González-Martín
Raúl González-Martín
AGAdrián Gutiérrez-Serpa
Adrián Gutiérrez-Serpa
Verónica PinoVerónica Pino
Verónica Pino
MSMuhammad Sajid
Muhammad Sajid
Sample preparation is a key step in most analytical methods, generally regarded as the least green step of the entire procedure. The existing green metrics assess the greenness of sample preparation techniques through the evaluation of the whole analytical procedure: including sampling, sample preparation, and the final detection/quantitation. Such inclusion of the entire method makes assessing the sustainability of a newly developed sample preparation technique quite challenging, as many aspects not solely linked to the sample preparation step are unavoidably considered. Thus, an alternative metric that can explicitly and exclusively evaluate the sample preparation is proposed. The metric is simple; it reports the result with a clock-like diagram, displaying the greenness outcome of main sample preparation parameters and a total score. This new metric can differentiate closely related microextraction approaches in terms of sustainability. The metric is also open-source and can be used by downloading the Excel sheet provided.

21 October 2022 in Journal of Chromatography A
Verified
Journal Article
Open access
RGRaúl González-Martín
Raúl González-Martín
ELEduardo Lodoso-Ruiz
Eduardo Lodoso-Ruiz
María J. Trujillo-RodríguezMaría J. Trujillo-Rodríguez
María J. Trujillo-Rodríguez
Verónica PinoVerónica Pino
Verónica Pino
Magnetic ionic liquids (MILs) are materials of special interest in analytical chemistry and, particularly, in analytical microextraction. These solvents possess several of the properties derived from their inherent nature of ionic liquids, combined with their magnetism, that permits their manipulation with an external magnetic field. This feature allows for performing typical steps of the microextraction procedure in a simpler manner with the aid of a strong magnet. Although there are several important reviews summarizing the most innovative advances in this field, there is a gap of information, as they do not provide useful details and tips related to the experimental set up of these procedures. This tutorial review fills this gap by providing a guide for the proper handling of MILs, their manipulation with magnets, and their proper hyphenation with the most used analytical techniques. Attention is paid to dispersive liquid-liquid microextraction, stir-bar dispersive liquid microextraction, aqueous biphasic systems, and single-drop microextraction, for being the analytical microextraction techniques mostly employed with MILs. This review also introduces a classification of the MILs employed in analytical microextraction in three classes (denoted as A, B, and C) as a function of the MIL nature (metal-containing anion, metal-containing cation, and radical-containing ion), and discuss about the prospect and future trends regarding new MIL families in microextraction together with new directions expected in these procedures.

9 April 2021 in Separations
Verified
Journal Article
Open access
PDF file
RGRaúl González-Martín
Raúl González-Martín
AGAdrián Gutiérrez-Serpa
Adrián Gutiérrez-Serpa
Verónica PinoVerónica Pino
Verónica Pino
Ferrofluids (FFs) constitute a type of tunable magnetic material, formed by magnetic nanoparticles suspended in a liquid carrier. The astonishing magnetic properties of these materials and their liquid nature have led to their extended use in different applications, including fields such as magnetochemistry, optics, and biomedicine, among others. Recently, FFs have been incorporated as extractant materials in magnetic-driven analytical sample preparation procedures, thus, permitting the development of different applications. FF-based extraction takes advantage of both the magnetic susceptibility of the nanoparticles and the properties of the liquid carrier, which are responsible for a wide variety of interactions with analytes and ultimately are a key factor in achieving better extraction performance. This review article classifies existing FFs in terms of the solvent used as a carrier (organic solvents, water, ionic liquids, deep eutectic solvents, and supramolecular solvents) while overviewing the most relevant analytical applications in the last decade.

8 September 2023 in Green Chemistry
Verified
Journal Article
Open access
PDF file
RGRaúl González-Martín
Raúl González-Martín
FSFrancisca A. e Silva
Francisca A. e Silva
María J. Trujillo-RodríguezMaría J. Trujillo-Rodríguez
María J. Trujillo-Rodríguez
DDDavid Díaz Díaz
David Díaz Díaz
JLJacob Lorenzo-Morales
Jacob Lorenzo-Morales
Verónica PinoVerónica Pino
Verónica Pino
Although saliva is a convenient human fluid for biomonitoring, current analytical set-ups for its analysis exhibit technical, sensitivity and instrumental compatibility constraints. To overcome these drawbacks, while following the Green Analytical Chemistry trends, this study is the first to propose the use of aqueous biphasic systems (ABSs) comprising the low cytotoxic butylguanidinium chloride ionic liquid (IL) and different salts as a saliva clean-up, microextraction and preconcentration tool. Among the developed and characterized ABSs, the one composed of the IL and K2HPO4 was selected to develop an integrated analytical procedure in saliva. Sample clean-up is achieved by removing 70% of the salivary proteins through precipitation as a solid interphase of the ABS – creating a three-phase partitioning (ABS/TPP) system – while a miniaturized extraction and preconcentration approach is simultaneously performed. The ABS/TPP, together with high-performance liquid chromatography and fluorescence detection (HPLC-FD), was optimized for bisphenols as representative biomarkers in saliva. Optimum conditions included 0.35 g of IL, 0.60 g of salt, 1.1 g of saliva, 1 min of stirring, and centrifugation. The ABS/TPP-HPLC-FD method exhibited enrichment factors up to ca. 3, extraction efficiencies higher than 80.5% despite using a miniaturized technique, and limits of detection down to 0.40 ng mL−1. The inter-day precision, expressed as relative standard deviation, was lower than 9.1%, achieving average relative recoveries of 106%. The method was successfully performed when analyzing male and female saliva. The green nature of the method as compared to other state-of-the-art techniques was demonstrated using several green metrics, scoring 0.63 in AGREEprep.

13 March 2024 in Analytica Chimica Acta
Verified
Journal Article
Open access
RGRaúl González-Martín
Raúl González-Martín
SJSirintorn Jullakan
Sirintorn Jullakan
María J. Trujillo-RodríguezMaría J. Trujillo-Rodríguez
María J. Trujillo-Rodríguez
NANabeel Mujtaba Abbasi
Nabeel Mujtaba Abbasi
SSShashini De Silva
Shashini De Silva
Verónica PinoVerónica Pino
Verónica Pino
The incorporation of bimetallic magnetic ionic liquids (MILs) in microextraction methods is an emerging trend due to the improved magnetic susceptibility offered by these solvents, which relies on the presence of metallic components in both the cation and the anion. This feature favors easy magnetic separation of these solvents in analytical sample preparation strategies. However, reported liquid-phase microextraction methods based on bimetallic MILs still present an important drawback in that the MILs are highly viscous, making a dispersive solvent during the microextraction procedure necessary, while also requiring a tedious back-extraction step prior to the chromatographic analysis. We propose for the first time a new generation of ultra-low viscosity bimetallic MILs composed of two paramagnetic Mn(II) complexes characterized by their easy usage in dispersive liquid-liquid microextraction (DLLME). The approach does not require dispersive solvent and the MIL-DLLME setup was directly combined with high-performance liquid chromatography (HPLC) and fluorescence detection (FD), without any back-extraction step. The approach was evaluated for the determination of five monohydroxylated polycyclic aromatic hydrocarbons, as carcinogenic biomarkers, in human urine. Optimum conditions of the MIL-DLLME method included the use of a low MIL volume (75 μL), a short extraction time (5 min), and no need of any dispersive solvent neither NaCl. The method presented limits of detection down to 7.50 ng L-1, enrichment factors higher than 17, and provided inter-day relative standard deviation lower than 11%. Analysis of urine samples was successfully performed, with biomarker content found at levels between 0.24 and 7.8 ng mL-1. This study represents the first liquid-phase microextraction method using the new generation of low-viscous bimetallic MILs. The proposed MIL-DLLME approach represents 2 important advances with respect to previous methods employing bimetallic MILs: 1) no dispersive solvent is required, and 2) direct injection of the MIL in the HPLC is possible after minor dilution (no back extraction steps are required). Therefore, the microextraction strategy is simple, rapid, and consumes very small amounts of energy.

30 August 2024 in Analytica Chimica Acta
Verified
Journal Article
Open access
RGRaúl González-Martín
Raúl González-Martín
María J. Trujillo-RodríguezMaría J. Trujillo-Rodríguez
María J. Trujillo-Rodríguez
Mara FreireMara Freire
Mara Freire
JAJuan H. Ayala
Juan H. Ayala
Verónica PinoVerónica Pino
Verónica Pino
Magnetic ionic liquids (MILs) have been explored in dispersive liquid-liquid microextraction (DLLME). Their usage allows to substitute centrifugation and/or filtration steps by a quick magnetic separation. Besides, effervescence-assisted DLLME is one of the most known options to improve the dispersion of the extractant in the sample, while allowing to avoid the consumption of external energy during dispersion. Despite these interesting features, only one study incorporates MILs containing the tetrachloroferrate anion in effervescence tablets. These MILs are highly viscous and liquid at room temperature, thus compromising the stability of the tablets when used as extraction microdevices in effervescence-assisted DLLME, and only allowing their use in the conventional MIL-DLLME mode. A new class of effervescence tablets containing a Ni(II)-based MIL, that is solid at room temperature, is here proposed. This type of tablets permits their use, for first time, in the in situ DLLME mode, occurring through the transformation of a water-soluble MIL into a water-insoluble MIL microdroplet. This way, the tablet formulation included: the MIL, the metathesis reagent lithium bis[(trifluoromethyl)sulfonyl]imide, NaH2PO4 and K2CO3 as effervescence precursors salts, and Na2SO4 as salting-out and desiccating agent. The method is combined with high-performance liquid-chromatography and both fluorescence and ultraviolet detection, for the determination of monohydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and benzophenones (BPs), as biomarkers in urine. The method simply involved the addition of the effervescence tablet to the sample, thus taken place simultaneously the effervescence process and the metathesis reaction, without requiring any external energy consumption. The method presented limits of detection down to 10 ng L-1 for OH-PAHs and to 0.60 μg L-1 for BPs, inter-day relative standard deviations lower than 17 %, and average relative recoveries of 94 % in urine. The determined OH-PAHs contents in urine were between 0.40 and 16 μg L-1, and between 17.8 and 334 μg L-1 for BPs. We have developed the first MIL-based effervescence tablets that are completely solid, thus improving the stability and robustness of these microdevices with respect to previously reported tablets involving MILs, while permitting to perform into the in situ DLLME mode (thus gaining in extraction efficiency). This approach including the MIL-based effervescence tablets constitutes an alternative on-site platform for the analysis of urine, as satisfactory precision, accuracy, and sensitivity are achieved despite not involving any external energy input within the analytical sample preparation setup. This method also constitutes the first application of MIL-based effervescence tablets for bioanalysis.