Salvatore Parrulli

Dr. Salvatore Parrulli

Luigi Sacco Hospital - ASST Fatebenefratelli Sacco
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in eClinicalMedicine
Verified
Journal Article
Open access
AIAlessandro Invernizzi
Alessandro Invernizzi
ATAlessandro Torre
Alessandro Torre
SPSalvatore Parrulli
Salvatore Parrulli
FZFederico Zicarelli
Federico Zicarelli
MSMarco Schiuma
Marco Schiuma
LMLuca Meroni
Luca Meroni
Coronavirus disease 2019 (COVID-19) has been associated to microvascular alterations. We screened the fundus of patients with COVID-19 to detect alterations of the retina and its vasculature and to assess possible correlations with clinical parameters. Cross-sectional study. The presence of retinal alterations in patients with COVID-19 and subjects unexposed to the virus was assessed using fundus photographs and their prevalence was compared. Mean arteries diameter (MAD) and mean veins diameter (MVD) were compared between patients and unexposed subjects with multiple linear regression including age, sex, ethnicity, body mass index, smoking/alcohol consumption, hypertension, hyperlipidaemia, diabetes as covariates. The influence of clinical/lab parameters on retinal findings was tested in COVID-19 patients. 54 patients and 133 unexposed subjects were enrolled. Retinal findings in COVID-19 included: haemorrhages (9·25%), cotton wools spots (7·4%), dilated veins (27·7%), tortuous vessels (12·9%). Both MAD and MVD were higher in COVID-19 patients compared to unexposed subjects (98·3 ± 15·3 µm vs 91·9 ± 11·7 µm, p = 0.006 and 138·5 ± 21·5 µm vs 123·2 ± 13·0 µm, p<0.0001, respectively). In multiple regression accounting for covariates MVD was positively associated with COVID-19 both in severe (coefficient 30·3, CI95% 18·1–42·4) and non-severe (coefficient 10·3, CI95% 1·6–19·0) cases compared to unexposed subjects. In COVID-19 patients MVD was negatively correlated with the time from symptoms onset (coefficient −1·0, CI 95% −1·89 to −0·20) and positively correlated with disease severity (coefficient 22·0, CI 95% 5·2–38·9). COVID-19 can affect the retina. Retinal veins diameter seems directly correlated with the disease severity. Its assessment could have possible applications in the management of COVID-19. None.

11 June 2020 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
SPSalvatore Parrulli
Salvatore Parrulli
FCFederico Corvi
Federico Corvi
MCMariano Cozzi
Mariano Cozzi
DMDavide Monteduro
Davide Monteduro
FZFederico Zicarelli
Federico Zicarelli
GSGiovanni Staurenghi
Giovanni Staurenghi
Background To compare fluorescein angiography (FA) and five different optical coherence tomography angiography (OCTA) devices and to test their reproducibility in the evaluation of retinal microaneurysms (MAs) secondary to diabetic retinopathy (DR). Methods On the same day, patients with DR were imaged with FA and five OCTA devices: prototype Spectralis OCTA, prototype PlexElite, RTVue XR Avanti, AngioPlex and DRI OCT Triton. For all OCTA devices, a 3×3 volume scan pattern was performed. MAs were evaluated for the superficial capillary plexus (SCP) and deep capillary plexus (DCP). Results Twenty eyes of 15 patients with DR were included. FA counted a significantly higher number of MAs compared to OCTA devices. Spectralis OCTA obtained a significantly higher number of MAs compared to PlexElite, RTVue XR Avanti, AngioPlex and DRI OCT Triton (p<0.0001). PlexElite and AngioPlex showed a greater number of MAs in the SCP, Spectralis OCTA, RTVue XR Avanti and DRI OCT Triton in the DCP. Higher sensitivity (43.3%) but lowest specificity (54.4%) was observed for Spectralis OCTA compared to other devices. The higher specificity (78.5%) and positive predictive value (83.3%) were observed for DRI OCT Triton. Conclusions FA remains the best imaging modality to visualise retinal MAs. Spectralis OCTA was able to detect more MAs compared to other devices, likely due to the higher number of B-scans in the scanned area as well as due to the higher number of repeated B-scans. The high variability between OCTA devices should be taken into account for future clinical trials as in clinical practice.

1 December 2020 in Ophthalmology Retina
Verified
Journal Article
Open access
FRFrancesco Romano
Francesco Romano
DMDavide Monteduro
Davide Monteduro
MAMatteo Airaldi
Matteo Airaldi
FZFederico Zicarelli
Federico Zicarelli
SPSalvatore Parrulli
Salvatore Parrulli
GSGiovanni Staurenghi
Giovanni Staurenghi

26 November 2021 in Ophthalmology Science
Verified
Journal Article
Open access
MCMatteo Giuseppe Cereda
Matteo Giuseppe Cereda
SPSalvatore Parrulli
Salvatore Parrulli
YDY.G.M. Douven
Y.G.M. Douven
KFKoorosh Faridpooya
Koorosh Faridpooya
SRSaskia van Romunde
Saskia van Romunde
MSMarc D. de Smet
Marc D. de Smet
To assess the efficacy of an instrument-integrated OCT (iiOCT)-based distance sensor during robotic vitreoretinal surgery using the Preceyes Surgical System (PSS; Preceyes B.V.). Single-center interventional study. Patients requiring vitreoretinal surgery. Five patients were enrolled. Standard preoperative OCT images were obtained. After vitrectomy, a predefined set of actions was performed using the iiOCT-based sensor. Images then were processed to assess the signal-to-noise ratio (SNR) at various angles to the retina and at different distances between the instrument tip and the retinal surface. Preoperative and intraoperative OCT images were compared qualitatively and quantitatively. The feasibility in performing surgical tasks using the iiOCT-based sensor during vitreoretinal surgery, the SNR when imaging the retina, differences among intraoperative and preoperative OCT images, and characteristics of intraoperative retinal movements detected with the iiOCT-based probe. Surgeons were able to perform all the tasks but one. The PSS was able to maintain a fixed distance. The SNR of the iiOCT-based sensor signal was adequate to determine the distance to the retina and to control the PSS. Analysis of iiOCT-based sensor A-scans identified 3 clearly distinguishable retinal layers, including the inner retinal boundary and the interface at the retinal pigment epithelium–Bruch’s membrane. Thickness values differed by less than 5% from that measured by preoperative OCT, indicating its accuracy. The Fourier analysis of iiOCT-based sensor recordings identified anteroposterior retinal movements attributed to heartbeat and respiration. This iiOCT-based sensor was tested successfully and promises reliable use during robot-assisted surgery. An iiOCT-based sensor is a promising step toward OCT-guided robotic retinal surgery.

27 May 2020 in Retina
Verified
Journal Article
Closed access
FPFrancesco Pichi
Francesco Pichi
SSScott D. Smith
Scott D. Smith
PNPiergiorgio Neri
Piergiorgio Neri
EWElizabeth Woodstock
Elizabeth Woodstock
SHSteven Hay
Steven Hay
AIAlessandro Invernizzi
Alessandro Invernizzi
Purpose: To assess the visualization of choroidal granulomas with swept-source optical coherence tomography angiography (OCTA). Methods: Consecutive patients with granulomatous choroiditis due to tuberculosis, sarcoidosis, or Vogt–Koyanagi–Harada disease underwent baseline OCTA images using a 12 × 12-mm field of view, and the choroidal slabs were analyzed by two independent examiners who counted the oval areas of flow void. Simultaneously, indocyanine green angiography (ICGA) and enhanced-depth imaging OCT were performed to mark visible choroidal changes corresponding to granulomatous lesions. The lesion areas on OCTA and ICGA were assessed using the in-built caliper tool. Results: Three hundred and one round-shaped areas of flow void on OCTA, 209 hypofluorescent round lesions on ICGA, and 42 hyporeflective choroidal lesions on enhanced-depth imaging OCT were identified in 23 eyes from 14 patients. Of the 209 ICGA granulomas, 197 (94.3%) had a corresponding round area of flow void on OCTA that was interpreted as a granuloma. One hundred and four additional round flow voids were identified on OCTA that did not correspond to any hypofluorescent lesion on ICGA. The mean area of the 197 granulomas detected with both imaging modalities was significantly larger on ICGA (mean 0.33 mm2) than that on OCTA (mean 0.28 mm2). Conclusion: Optical coherence tomography angiography seems to be an optimal imaging method for the visualization of choroidal granulomas.

24 September 2022 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
AGAndrea Govetto
Andrea Govetto
Daniela BacheriniDaniela Bacherini
Daniela Bacherini
MRMario R. Romano
Mario R. Romano
MMMartina Matteucci
Martina Matteucci
SLSara Lucchini
Sara Lucchini
PRPaolo Radice
Paolo Radice